NOTE:

The controller is compatible with the IEEE 802.3ab standard including the Auto

MDI/MDI-X feature, which allows use of either straight-through or crossover twisted-pair cables
for connecting to any network devices including end nodes, such as computers, or to other
switches, hubs, and routers.

For 1000 Mbps operation, all four wire pairs are used for data transmission.

Installation location—Before installing the controller, plan its location relative to other devices and
equipment, and consider the following:

The front of the controller requires at least 7.6 cm (3 inches) of space for the twisted-pair cabling.

The back of the controller requires at least 3.8 cm (1.5 inches) of space for the power cord.

The sides of the controller require at least 7.6 cm (3 inches) for cooling, except if the controller is
installed in an open EIA/TIA rack.

Installing the controller

After determining the configuration and preparing the site, mount the controller in a stable location. The
controller can be installed in a rack or cabinet, or placed on a table or shelf.

Mounting the controller in a rack or cabinet

The controller can be mounted in any EIA-standard 19-inch telco rack or communication equipment cabinet.

IMPORTANT:

Equipment Cabinet Note

The four 12-24 screws supplied with the controller have the correct threading for standard EIA/TIA
open 19-inch racks. If you are installing the controller in an equipment cabinet, such as a server
cabinet, use the clips and screws that came with the cabinet instead of the 12-24 screws that are
supplied with the controller.

Before performing the following procedure, determine which four holes you will be using in the cabinet
and install all four clips.

1.

Use a #1 Phillips (cross-head) screwdriver to attach the mounting brackets to the controller with the
included 8-mm M4 screws.

Figure 2 Controller with mounting brackets

Содержание ProCurve MSM760

Страница 1: ...d Locator LEDs 6 USB port not used 2 Ethernet Ports 1 Internet 2 LAN 7 Ethernet LEDs 3 Console port 4 LCD display Package contents Controller console cable two mounting brackets eight 8 mm screws four 5 8 inch screws four rubber feet power cord and documentation LCD display The LCD displays the following The controller type either Mobility Controller or Access Controller The maximum number of supp...

Страница 2: ...ndition persists contact technical support Flashing The controller is fully operational On The normal state it indicates that there are no fault conditions on the controller Off Fault orange A fault has occurred on the controller Flashing On briefly at the beginning of the self test after the controller is powered on or reset If it remains on the controller has encountered a fatal hardware failure...

Страница 3: ...es not overload the power circuits wiring and over current protection To determine the power supply circuit load add the ampere ratings of all devices installed on the circuit including the controller and compare the total with the rating limit for the circuit The maximum ampere ratings are typically printed on the devices near the AC power connectors Do not install the controller in an environmen...

Страница 4: ...EIA TIA rack Installing the controller After determining the configuration and preparing the site mount the controller in a stable location The controller can be installed in a rack or cabinet or placed on a table or shelf Mounting the controller in a rack or cabinet The controller can be mounted in any EIA standard 19 inch telco rack or communication equipment cabinet IMPORTANT Equipment Cabinet ...

Страница 5: ...n reconnecting the power cord or by using its management tool Resetting to factory defaults HP recommends that you use the controller web interface to reset the controller to factory defaults as described in the HP MSM760 Controllers Installation Guide Support and other resources For worldwide technical support information see the HP support website at www hp com support The HP MSM7xx Controllers ...

Страница 6: ...December Дата изготовления Дата изготовления включена в серийный номер изделия CCYMPPPZZZ формат серийного номера HP для данного изделия Дата изготовления указана как YM в серийном номере где Y соответствует году с началом отсчета в каждом новом десятилетии начиная с 2010 а M соответствует месяцу изготовления устройства Например в обозначении 3A цифра 3 соответствует 2013 году а A обозначает ноябр...

Страница 7: ...F Relative humidity nl non condensing Operating 2 km 6 500 ft Non operating 4 6 km 15 000 ft Maximum altitude Noise Emission LwA 52 dB at virtual work space according to DIN 45635 T 19 Acoustic The 10 100 1000 Mbps RJ 45 twisted pair ports are compatible with IEEE 802 3ab 1000Base T IEEE 802 3u 100Base TX and IEEE 802 3 10Base T standards Connectors Complies with EN60950 1 IEC 60950 1 CSA 22 2 No ...

Отзывы: