background image

HP ProCurve Networking

2

HP ProCurve 4.4dBi Indoor/Outdoor Omnidirectional Antenna (J8441A) Guide

MOUNTING

Suspended ceiling mount

1.  Attach the antenna to the antenna bracket (77) using two #6 phillips 

head screws (90) and two #6 lock washers (89). Use the #6 hardware 

to secure the antenna bracket to the antenna base. See Figure 2.

2.  Remove the 1/4” - 20 hex nut and flat washer from the runner 

bracket (78) carriage bolt in preparation for mounting. Discard the flat 

washer–this will not be used. 

3.  Insert the antenna bracket (77) onto the threaded end of the runner 

bracket bolt (78) as shown in Figure 2. Install the 1/4” lock washer 

(16) and nut loosely–the halves of the runner bracket must slide freely 

for final installation. 

4.  Clamp the ceiling bracket onto the support runner and tighten the 1/4” 

mounting nut using a 7/16” wrench or adjustable wrench. Secure 

 

the coaxial cable along the support runner using tape or cable ties. 

5.  If installing one antenna, attach the connector to the AP Primary 

antenna connection. If installing a diversity system, attach the 

 

leads from the two antennas to the AP main and auxiliary antenna 

 

connectors. 

I-beam mount

1.  Install bracket plate (77) as shown in Figure 2.
2.  Referring to Figure 2A, install I-beam clamp (80) to the bracket plate 

using flat washer (04), lock washer (84), and short 1/4”-20 bolt (55). 

Tighten the clamp bolt to secure the antenna in place on the I-beam. 

Pole mount

1.  At the top of the pipe, using a 1/2” wrench or adjustable wrench, 

 

secure the U-bolt (05) to the mast clamp (26) using two 5/16” nuts 

(18), lock washers (19), and flat washers (02). See Figure 3.

2.  Install two 5/16” nuts (18) by turning them down against the nuts 

securing the U-bolt of the mast. 

3.  Sandwich the antenna between the two antenna clamps (48) at its 

base and slide this assembly onto the U-bolt. Secure in place using 

two 5/16” lock washers (19), and the two remaining 5/16” nuts (18). 

4.  Secure the coaxial cable along the mast or pole using tape or 

 

cable ties. 

5.  If installing one antenna, attach the connector to the AP Primary 

antenna connection. If installing a diversity system, attach the leads 

from the two antennas to the AP unit’s 

Primary

 and 

Secondary jacks.  

Figure 2

Figure 3

Figure 2A