background image

ProCurve Switch 3500yl-24G-PWR

Specifications

Ports

1 open module slots
20 10/100/1000 ports (IEEE
802.3 Type 10Base-T, IEEE
802.3u Type 100Base-TX, IEEE
802.3ab 1000Base-T Gigabit
Ethernet)
Supports a maximum of 4
10-GbE ports
1 RS-232C DB-9 console port
4 dual-personality ports - each
port can be used as either an
RJ-45 10/100/1000 port (IEEE
802.3 Type 10Base-T; 802.3u
Type 100Base-TX; 802.3ab
1000Base-T Gigabit Ethernet)
or an open mini-GBIC slot (for
use with mini-GBIC
transceivers)

Power Supplies

Physical characteristics

Dimensions
15.43(d) x 17.44(w) x 1.73(h)
in. (39.2 x 44.3 x 4.4 cm) (1U
height)
Weight
14.11 lb. (6.4 kg)

Memory and processor

10G Module: ARM9 @ 200
MHz; packet buffer size: 36 Mb
QDR SDRAM
Exceptions: Stackable memory
and processor: Freescale
PowerPC 8540 @ 666 MHz, 4
MB flash, 128 MB compact
flash, 256 MB DDR SDRAM

Mounting

Mounts in an EIA-standard 19
in. telco rack or equipment
cabinet (hardware included);
horizontal surface mounting
only

Performance

Latency:

- 1000 Mb: <3.7 µs (FIFO

64-byte packets)

- 10Gbps: <2.1 µs (FIFO

64-byte packets)

Throughput: up to 74 million
pps (64-byte packets)
Routing/switching capacity:
101 Gbps
Switch fabric speed: 115 Gbps
Routing table size: 10,000
entries

Environment

Operating

- Temperature: 32°F to 131°F

(0°C to 55°C); 32°F to
104°F (40°C) when used
with any X2 10-GbE

- Relative humidity: 15% to

95% @ 104°F (40°C),
non-condensing

- Altitude: up to 15,091 ft.(4.6

km)

Non-operating/Storage

- Temperature: -40°F to

158°F (-40°C to 70°C)

- Relative humidity: 15% to

90% @ 149°F (65°C),
non-condensing

Acoustic: DIN 45635T.19 per
ISO 7779 55.1 dB

Electrical characteristics

The switch automatically
adjusts to any voltage between
100-127 and 200-240 volts
and either 50 or 60 Hz
Max heat dissipation: 2590
BTU/hr, including the switch
and max number of attached
PoE devices; switch only is
1,330 BTU/hr
Voltage: 100-127
VAC/200-240 VAC
Current: 10.0 A/5.0 A
Power consumption: 759 W
Frequency: 50/60 Hz

Safety

CSA 22.2 No. 60950;
UL 60950; IEC60950;
EN60950

Emissions

FCC Class A;
EN55022/CISPR-22 Class A;
VCCI Class A

Immunity

EN: EN55024, CISPR 24
ESD: IEC 61000-4-2; 4 kV CD,
8 kV AD
Radiated: IEC 61000-4-3;
3V/m
EFT/Burst: IEC 61000-4-4; 1.0
kV (power line), 0.5 kV (signal
line)
Surge: IEC 61000-4-5; 1 kV/2
kV AC
Conducted: IEC 61000-4-6; 3V
Power frequency magnetic
field: IEC 61000-4-8; 1A/m, 50
or 60 Hz
Voltage dips and interruptions:
IEC 61000-4-11; >95%
reduction, 0.5 period; 30%
reduction, 25 periods
Harmonics: EN61000-3-2,
IEC61000-3-2
Flicker: EN61000-3-3,
IEC61000-3-3

Management

ProCurve Manager Plus;
ProCurve Manager (included);
command-line interface; Web
browser; configuration menu;
out-of-band management
(serial RS-232C)

Standards and protocols

RFC 783 TFTP;
RFC 951 BootP;
RFC 1542 BootP;
RFC 854 Telnet;
RFC 768 UDP;
RFC 792 ICMP;
RFC 793 TCP; RFC 826 ARP;
RFC 2030 Simple Network
Time Protocol;
IEEE 802.3x Flow Control;
DHCP Relay;
RFC 3376 IGMPv1/v2/v3;

RFC 2453 RIPv2;
RFC 2328 OSPFv2 (Premium
Edge License);
IGMPv3;
IEEE 802.1D Spanning Tree;
IEEE 802.1w Rapid
Convergence Spanning Tree;
IEEE 802.1s Multiple Spanning
Trees;
IEEE 802.3ad Link Aggregation
Control Protocol;
IEEE 802.1AB Link Layer
Discovery Protocol;
ANSI/TIA-1057 LLDP Media
Endpoint Discovery (MED);
RFC 2474 DiffServ Precedence;
RFC 2597 DiffServ Expedited
Forwarding (EF);
RFC 2598 DiffServ Assured
Forwarding (AF);
RFC 1492 ;
RFC 2138 RADIUS;
RFC 2866 RADIUS accounting;
SSHv1/SSHv2 Secure Shell;
Secure Sockets Layer (SSL);
IEEE 802.1X Network Login;
802.3af Power over Ethernet;
IEEE 802.1Q VLAN tagging;
IEEE 802.1Q GVRP;
IEEE 802.1p Priority;
SNMPv1/v2c/v3;
HTML and telnet management;
RFC 1493 Bridge MIB;
PIM Dense Mode (Premium
Edge License);
PIM Sparse Mode (Premium
Edge License);
RFC 1213 MIB II;
RFC 2096 IP Forwarding Table
MIB;
RFC 2737 Entity MIB;
RFC 2863 Evolution of
Interface;

RFC 2665 Ethernet MIB;
RFC 3768 VRRP (Premium
Edge License);
RFC 2787 VRRP MIB;
RFC 1058 RIP;
RFC 1724 RIPv2 MIB;
RFC 2819 Four groups of
RMON: 1 (statistics), 2
(history), 3 (alarm) and 9
(events);
XRMON; sFlow;
RFC 2021 RMON probe
configuration (RMON v2);
RFC 2668 802.3 MAU MIB;
RFC 2613 SMON;
RFC 2674 802.1p and IEEE
802.1Q Bridge MIB;
RFC 1850 OSPF MIB;
RFC 2618 RADIUS Client MIB;
RFC 2620 RADIUS Accounting
MIB;
RFC 3046 DHCP Relay Agent
Information Option

Notes

When using mini-GBICs with
this product, mini-GBICs with
revision "B" (product number
ends with the letter "B", e.g.
J4858B, J4859B) or later are
required.
J8177B Gigabit 1000Base-T
mini-GBIC is not supported on
Switch 3500.

5

Содержание ProCurve 3500yl-24G-PWR

Страница 1: ... foundation for this switch is a purpose built programmable ProVision ASIC that allows the most demanding networking features such as QoS and security to be implemented in a scalable yet granular fashion The 3500yl 24G PWR is a part of the ProCurve 3500yl 5400zl series of switches that offer unprecedented investment protection flexibility and scalability as well as ease of deployment operation and...

Страница 2: ... ports per trunk trunking across modules is supported Hot swappable modules 5400zl series permit modules mini GBICs and power supplies in a redundant power supply configuration to be added or swapped without interrupting the network Optional redundant power supply 5400zl series provides uninterrupted power and allows hot swapping of the redundant power supplies when installed Layer 2 switching Pro...

Страница 3: ...pecified ports to communicate with each other TACACS eases switch management security administration by using a password authentication server Secure Shell SSHv2 encrypts all transmitted data for secure remote command line interface CLI access over IP networks Secure Sockets Layer SSL encrypts all HTTP traffic allowing secure access to the browser based management GUI in the switch Secure FTP allo...

Страница 4: ...ions Friendly port names allow assignment of descriptive names to ports Dual flash images provide independent primary and secondary OS files for backup while upgrading Multiple configuration files multiple config files can be stored to flash image Port mirroring enables troubleshooting by mirroring ingress egress traffic on a port Services 3 year 4 hour onsite 13x5 coverage for hardware U2855E 3 y...

Страница 5: ...C 61000 4 3 3V m EFT Burst IEC 61000 4 4 1 0 kV power line 0 5 kV signal line Surge IEC 61000 4 5 1 kV 2 kV AC Conducted IEC 61000 4 6 3V Power frequency magnetic field IEC 61000 4 8 1A m 50 or 60 Hz Voltage dips and interruptions IEC 61000 4 11 95 reduction 0 5 period 30 reduction 25 periods Harmonics EN61000 3 2 IEC61000 3 2 Flicker EN61000 3 3 IEC61000 3 3 Management ProCurve Manager Plus ProCu...

Страница 6: ... diameter graded index low metal content multimode fiber optic complying with ITU T G 651 and ISO IEC 793 2 Type A1b or A1a respectively Low metal content single mode fiber optic complying with ITU T G 652 and ISO IEC 793 2 Type B1 Maximum distance 10 km single mode or 550 m multimode Notes A mode conditioning patch cord may be needed in some multimode fiber installations ProCurve Gigabit SX LC Mi...

Страница 7: ... greater Not supported on dual personality ports ProCurve Switch 10 GbE X2 CX4 Transceiver J8440B 10 Gigabit X2 transceiver that supports a CX4 connector with distance of 15 m Ports Connector CX4 Duplex full Physical characteristics Dimensions 3 54 d x 1 42 w x 0 53 h in 8 99 x 3 61 x 1 35 cm Weight 0 18 lb 0 08 kg Environment Operating temperature 32 F to 131 F 0 C to 55 C Operating relative humi...

Страница 8: ...ronment Operating temperature 32 F to 104 F 0 C to 40 C Operating relative humidity 15 to 95 non condensing Cabling Low metal content single mode fiber optic complying with ITU T G 652 and ISO IEC 793 2 Type B1 Maximum distance 9 125 um single mode cable 2 m 10 km Notes Conditioning patch cord cables are not supported ProCurve 10 GbE X2 SC SR Optic J8436A Transceiver that supports 10G SR fiber sta...

Страница 9: ...et Explorer version 5 0 or later Supported platforms HP OpenView Network Node Manager version 6 41 or 7 01 or 7 5 RADIUS server support Microsoft IAS Features Device auto discovery Topology and mapping Intuitive Explorer style interface Usable troubleshooting data and alerts Device configuration and management Customize and execute policies across groups Enhanced network security features Multiple...

Страница 10: ...tion Application of policies by user identity Auto VLAN assignment Auto set quality of service by user Auto set bandwidth assignment by user Rule based access rights deployment Dynamic rights assignment based on Time Location User system Auto discovery of RADIUS servers Realms Users Additional requirements Large numbers of users may require more disk space Power supplies ProCurve Switch zl 875W Po...

Страница 11: ... ProCurve Switch 3500yl series and ProCurve Switch 6200yl 24G mGBIC Ports 2 open transceiver slots 2 10 Gigabit Ethernet ports IEEE 802 3ak Type 10Gbase CX4 Duplex full Physical characteristics Dimensions 7 76 d x 7 52 w x 14 29 h in 19 7 x 19 1 x 36 3 cm Weight 1 54 lb 7 kg Environment Operating temperature 32 F to 131 F 0 C to 55 C Operating relative humidity 15 to 95 non condensing Non operatin...

Страница 12: ...edia converter with ribbon MMF Notes Only the two fixed CX4 ports on this module support ProCurve 10 GbE CX4 Media Converter J8439A Operating temperature is 32Â F to 104Â F 0Â C to 40Â C if any X2 10 GbE optic or transceiver is inserted in any X2 slot One 0 5m CX4 cable is included zl Modules ProCurve Switch 5400zl 24p Mini GBIC Module J8706A 24 port mini GBIC module for 5400 series switches Ports...

Страница 13: ...uplex half or full Physical characteristics Dimensions 10 3 d x 8 13 w x 1 75 h in 26 16 x 20 65 x 4 45 cm Weight 2 2 lb 1 kg Environment Operating temperature 32 F to 104 F 0 C to 40 C Mini GBICs supported ordered separately ProCurve Gigabit SX LC Mini GBIC ProCurve Gigabit LX LC Mini GBIC ProCurve Gigabit LH LC Mini GBIC ProCurve Gigabit 1000Base T Mini GBIC Notes This product requires revision ...

Страница 14: ...74 lb 0 79 kg Environment Operating temperature 32 F to 104 F 0 C to 40 C Transceivers supported ordered separately ProCurve 10 GbE X2 SC LR Optic ProCurve Switch 10 GbE X2 CX4 Transceiver ProCurve 10 GbE X2 SC SR Optic ProCurve 10 GbE X2 SC ER Optic Notes When installed in a 5400 chassis the J8707A module limits the operating temperature range of the chassis to 32Â F to 104Â F 0Â C to 40Â C ProCu...

Страница 15: ...d services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein 06 16 06 To learn more visit www procurve com Information is subject to change without notice ...

Отзывы: