background image

HP ProCurve Switch 2610 Series

7

Specifications

HP ProCurve Switch 2610-48-PWR (J9089A)

HP ProCurve Switch 2610-24/12PWR (J9086A)

Ports

48 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE
802.3u Type 100Base-TX); Media Type: Auto-MDIX; Duplex: half or
full

24 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE
802.3u Type 100Base-TX); Media Type: Auto-MDIX; Duplex: half or
full

1 RJ-45 serial console port

1 RJ-45 serial console port

2 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE
802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T); Duplex:
10Base-T/100Base-TX: half or full; 1000Base-T: full only

2 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE
802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T); Duplex:
10Base-T/100Base-TX: half or full; 1000Base-T: full only

2 open mini-GBIC (SFP) slots

2 open mini-GBIC (SFP) slots

Physical characteristics

Dimensions

13.5(d) x 17.4(w) x 1.73(h) in. (34.29 x 44.2 x 4.39 cm) (1U height)

9.3(d) x 17.4(w) x 1.73(h) in. (23.62 x 44.2 x 4.39 cm) (1U height)

Weight

16.7 lb. (7.58 kg), Fully loaded

7.5 lb. (3.4 kg)

Memory and processor

Processor

MIPS @ 300 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size:
2 MB

MIPS @ 300 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size:
1 MB

Mounting

Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
(hardware included); horizontal surface mounting only

Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
(hardware included); horizontal surface mounting only

Performance

100 Mb Latency

< 6.2 µs (LIFO)

< 4.1 µs

1000 Mb Latency

< 4.4 µs (LIFO)

< 2.9 µs

Throughput

up to 13.0 million pps

up to 9.5 million pps

Routing/Switching capacity

17.6 Gbps

12.8 Gbps

MAC address table size

8000 entries

8000 entries

Environment

Operating temperature

32ºF to 122ºF (0ºC to 50ºC)

32ºF to 122ºF (0ºC to 50ºC)

Operating relative humidity

15% to 95% @ 104ºF (40ºC), non-condensing

15% to 95% @ 104ºF (40ºC), non-condensing

Non-operating/Storage temperature

-40ºF to 158ºF (-40ºC to 70ºC)

-40ºF to 158ºF (-40ºC to 70ºC)

Non-operating/Storage relative humidity

15% to 90% @ 149ºF (65ºC), non-condensing

15% to 90% @ 149ºF (65ºC), non-condensing

Altitude

up to 10000 ft. (3 km)

up to 10000 ft. (3 km)

Acoustic

Power: 63.6 dB, Pressure: 56.6 dB; DIN 45635T.19 per ISO 7779

Power: 46 dB, Pressure: 38.4 dB; DIN 45635T.19 per ISO 7779

Electrical characteristics

Maximum heat dissipation

410 BTU/hr (432.55 kJ/hr), (switch-only BTU/hr: 410; combined
max. PoE devices at 15.4 W: 2281 BTU/hr)

181 BTU/hr (190.96 kJ/hr), (switch-only BTU/hr: 181; combined
max. PoE devices at 15.4 W: 827 BTU/hr)

Voltage

100-127 / 200-240 VAC

100-127 / 200-240 VAC

Current

7.0 / 3.5 A

3.3 / 1.7 A

Power consumption

96 W

62 W

Frequency

50 / 60 Hz

50 / 60 Hz

Notes

Maximum power rating is the worst-case theoretical maximum power
number with fully loaded PoE, 100% traffic, all ports plugged in, and
all modules populated.
Power consumption: 96 W without PoE; 590 W with PoE.

Maximum power rating is the worst-case theoretical maximum power
number with fully loaded PoE, 100% traffic, all ports plugged in, and
all modules populated.
Power consumption: 62 W without PoE; 189 W with PoE.

Содержание ProCurve 2610-12PWR

Страница 1: ...ces The HP ProCurve 2610 24 12PWR 2610 24 PWR and 2610 48 PWR are IEEE 802 3af compliant for Power over Ethernet PoE and provide up to 15 4 W for 12 24 and 48 ports The 2610 24 12PWR has 24 10 100 ports and provides 12 ports of PoE All switches include two 10 100 1000Base T ports and two mini GBIC slots for Gigabit uplink connectivity An optional redundant external power supply is also available t...

Страница 2: ...nvironments by allowing multiple spanning trees provides legacy support for IEEE 802 1d and IEEE 802 1w Optional redundant power supply provides uninterrupted power provided by HP ProCurve 600 RPS EPS Manageability RMON XRMON and sFlow provide advanced monitoring and reporting capabilities for statistics history alarms and events Uni Directional Link Detection UDLD monitors a link between two swit...

Страница 3: ...unwanted file downloads or unauthorized copying of switch configuration file Switch management logon security can require either RADIUS or TACACS authentication for secure switch CLI logon DHCP protection blocks DHCP packets from unauthorized DHCP servers preventing denial of service attacks STP BPDU port protection blocks Bridge Protocol Data Units BPDUs on ports that do not require BPDUs prevent...

Страница 4: ... MB MIPS 300 MHz 16 MB flash 128 MB SDRAM packet buffer size 1 MB MIPS 300 MHz 16 MB flash 128 MB SDRAM packet buffer size 1 MB Mounting Mounts in an EIA standard 19 in telco rack or equipment cabinet hardware included horizontal surface mounting only Mounts in an EIA standard 19 in telco rack or equipment cabinet hardware included horizontal surface mounting only Mounts in an EIA standard 19 in t...

Страница 5: ...C IEC 61000 4 5 1 kV 2 kV AC IEC 61000 4 5 1 kV 2 kV AC Conducted IEC 61000 4 6 3V IEC 61000 4 6 3V IEC 61000 4 6 3V Power frequency magnetic field IEC 61000 4 8 1A m 50 or 60 Hz IEC 61000 4 8 1A m 50 or 60 Hz IEC 61000 4 8 1A m 50 or 60 Hz Voltage dips and interruptions IEC 61000 4 11 95 reduction 0 5 period 30 reduction 25 periods IEC 61000 4 11 95 reduction 0 5 period 30 reduction 25 periods IE...

Страница 6: ... year 24x7 SW phone support software updates UF792E Installation with minimum configuration system based pricing U4826E Installation with HP provided configuration system based pricing U4830E Refer to the HP Web site at www procurve com services for details on the service level descriptions and product numbers For details about services and response times in your area please contact your local HP ...

Страница 7: ...izontal surface mounting only Performance 100 Mb Latency 6 2 µs LIFO 4 1 µs 1000 Mb Latency 4 4 µs LIFO 2 9 µs Throughput up to 13 0 million pps up to 9 5 million pps Routing Switching capacity 17 6 Gbps 12 8 Gbps MAC address table size 8000 entries 8000 entries Environment Operating temperature 32ºF to 122ºF 0ºC to 50ºC 32ºF to 122ºF 0ºC to 50ºC Operating relative humidity 15 to 95 104ºF 40ºC non...

Страница 8: ...sing mini GBICs with this product mini GBICs with revision B or later product ends with the letter B or later e g J4858B J4859C are required When using mini GBICs with this product mini GBICs with revision B or later product ends with the letter B or later e g J4858B J4859C are required Services 3 year 4 hour onsite 13x5 coverage for hardware U4683E 3 year 4 hour onsite 24x7 coverage for hardware ...

Страница 9: ...ons RFC 2030 Simple Network Time Protocol SNTP v4 RFC 2131 DHCP RFC 3046 DHCP Relay Agent Information Option IP multicast RFC 3376 IGMPv3 MIBs RFC 1213 MIB II RFC 1493 Bridge MIB RFC 2021 RMONv2 MIB RFC 2096 IP Forwarding Table MIB RFC 2613 SMON MIB RFC 2618 RADIUS Client MIB RFC 2665 Ethernet Like MIB RFC 2668 802 3 MAU MIB RFC 2674 802 1p and IEEE 802 1Q Bridge MIB RFC 2737 Entity MIB Version 2 ...

Страница 10: ...ply J8169A HP ProCurve Manager 2 3 HP ProCurve Network Immunity Manager 1 0 50 device license J9060A HP ProCurve Network Immunity Manager 1 0 100 device license J9061A HP ProCurve Network Immunity Manager 1 0 unlimited device license J9062A For more information To learn more about HP ProCurve Networking please visit ProCurve com 2008 Hewlett Packard Development Company L P The information containe...

Отзывы: