![HP ProCurve 1600M Скачать руководство пользователя страница 434](http://html.mh-extra.com/html/hp/procurve-1600m/procurve-1600m_management-and-configuration-manual_155305434.webp)
Redundancy (Switch 8212zl)
Using Redundant Management
management-module2:
Configures management-module 2 as
the active management module for the next system boot.
standby:
Configures the current standby module as the active
management module for the next system boot if redundancy
is enabled. If redundancy is disabled, it will become enabled
as a standby module at the next boot or failover event.
If the specified management module is not there or is in failed mode, this
message displays:
The <specified module> is not present or is in failed
state.
Figure 15-5 shows an example of setting management module 2 to be the active
management module.
ProCurve(config)# redundancy active-management management-module2
On the next system boot, the management-module2 will become active.
ProCurve(config)# boot system
(boot occurs...)
ProCurve(config)# show redundancy
Settings
--------
Mgmt Redundancy : enabled
Statistics
----------
Failovers : 0
Last Failover :
Slot Module Description
Status SW Version
MM1 ProCurve J9092A Management Module 8200zl Standby K.12.30
MM2 ProCurve J9092A Management Module 8200zl Active K.12.30
---- ---------------------------------------- ------ ----------
Boot Image
----------
Primary
Primary
FM1
FM2
ProCurve J9093A Fabric Module 8200zl
ProCurve J9093A Fabric Module 8200zl
Enabled
Enabled
Figure 15-5. Setting a Management Module to be Active on the Next Boot
If redundancy has been disabled and you specify the standby module with the
active-management
command, upon rebooting the offline module becomes the
standby module. The state of redundancy (enabled or disabled) is based on
the value in the configuration file in the offline (now standby) module. The
configuration files haven’t been synchronized if redundancy has been
15-10
Содержание ProCurve 1600M
Страница 1: ...Management and Configuration Guide 8200zl ProCurve Switches K 12 XX www procurve com ...
Страница 2: ......
Страница 3: ...ProCurve Series 8200zl Switches September 2007 K 12 xx Management and Configuration Guide ...
Страница 68: ...Using the Menu Interface Where To Go From Here 3 16 ...
Страница 110: ...Using the ProCurve Web Browser Interface Status Reporting Features 5 26 ...
Страница 152: ...Switch Memory and Configuration Multiple Configuration Files 6 42 ...
Страница 192: ...Configuring IP Addressing IP Preserve Retaining VLAN 1 IP Addressing Across Configuration File Downloads 8 24 ...
Страница 220: ...Time Protocols SNTP Messages in the Event Log 9 28 ...
Страница 252: ...Port Status and Configuration Uni Directional Link Detection UDLD 10 32 ...
Страница 282: ...Power Over Ethernet PoE Operation PoE Operating Notes 11 30 ...
Страница 472: ...Redundancy Switch 8212zl Event Log Messages 15 48 ...
Страница 510: ...File Transfers Copying Diagnostic Data to a Remote Host USB Device PC or UNIX Workstation A 38 ...
Страница 584: ...Monitoring and Analyzing Switch Operation Locating a Device B 74 ...
Страница 652: ...Troubleshooting Restoring a Flash Image C 68 ...
Страница 660: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Страница 666: ...Monitoring Resources When Insufficient Resources Are Available E 6 ...
Страница 670: ...Daylight Savings Time on ProCurve Switches F 4 ...
Страница 688: ...18 Index ...
Страница 689: ......