background image

Operating relative
humidity

15% to 95% @ 104°F (40°C), noncondensing

Nonoperating/Storage
temperature

-40°F to 158°F (-40°C to 70°C)

Nonoperating/Storage
relative humidity

15% to 90% @ 149°F (65°C), noncondensing

Altitude

up to 10,000 ft. (3 km)

Acoustic

Power: 0 dB No fan

Electrical characteristics Frequency

50/60 Hz

Maximum heat
dissipation

13 BTU/hr (13.72 kJ/hr)

Voltage

100 - 240 VAC

DC voltage

12 V

Current

0.3 A

Maximum power rating

3.6 W

Notes

Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure with
fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all
modules populated.

The exact input voltage and frequency rating are determined by the specific
power adaptor part number ordered. Please select the correct power adaptor
country option.

Safety

UL 60950-1; CSA 22.2 60950-1; IEC 60950-1:2005; EN 60950-1:2006 + A11:2009

Emissions

FCC Rules Part 15, Subpart B Class A

Immunity

Generic

EN 55022 CISPR 22

EN

EN 55024, CISPR 24

ESD

IEC 61000-4-2

Radiated

IEC 61000-4-3

EFT/Burst

IEC 61000-4-4

Surge

IEC 61000-4-5

Conducted

IEC 61000-4-6

Power frequency
magnetic field

IEC 61000-4-8

Voltage dips and
interruptions

IEC 61000-4-11

Harmonics

IEC 61000-3-2

Flicker

IEC 61000-3-3

Services

3-year, 4-hour onsite, 13x5 coverage for hardware (UF795E)
3-year, 4-hour onsite, 24x7 coverage for hardware (UF796E)
1-year, post-warranty, 4-hour onsite, 13x5 coverage for hardware (HR843E)
1-year, post-warranty, 4-hour onsite, 24x7 coverage for hardware (HR844E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UR817E)

QuickSpecs

HP 1410 Switch series

Technical Specifications

DA - 13674   Worldwide — Version 12 — December 16, 2013

Page  13

Содержание ProCurve 1410-24G

Страница 1: ...ide outstanding data efficiency Simplified plug and play convenience is enabled by features such as Auto MDIX and auto speed negotiation HP has innovated and combined the latest advances in silicon technology to bring you some of the most power efficient switches 1410 24G R 1410 16 and 1410 24 models are advanced IEEE 802 3az compliant unmanaged Gigabit and Fast Ethernet switches The switches come...

Страница 2: ... neat operation environment JG708A J9561A and JD986B switches Warranty and support NEW Lifetime Warranty 2 0 advance hardware replacement for as long as you own the product with next business day delivery available in most countries NEW Electronic and telephone support for Lifetime Warranty 2 0 limited 24x7 telephone support is available from HP for the first 3 years limited electronic and busines...

Страница 3: ...ual personality ports either an RJ 45 10 100 1000 port or an open mini GBIC slot 1U Height See Configuration Note 1 3 PDU Cable NA MX TW JP J9561A B2B C15 PDU Jumper Cord NA MX TW JP PDU Cable ROW J9561A B2C C15 PDU Jumper Cord ROW HP 1410 8 Switch J9661A 8 autosensing 10 100 ports See Configuration Note 2 HP 1410 16 Switch J9662A 16 autosensing 10 100 ports 1U Height See Configuration Note 2 HP 1...

Страница 4: ...r supplies included Enter the following menu selections as integrated to the CTO Model X server above if order is factory built Transceivers SFP Transceivers HP X121 1G SFP LC SX Transceiver J4858C HP X121 1G SFP LC LX Transceiver J4859C HP X111 100M SFP LC FX Transceiver J9054C Cables Multi Mode Cables HP 5m Multi mode OM3 LC LC FC Cable AJ833A HP 1m Multi mode OM3 LC LC FC Cable AJ834A HP 2 m Mu...

Страница 5: ... LC LC OM4 2f 5m Cbl QK734A HP Premier Flex LC LC OM4 2f 15m Cbl QK735A HP Premier Flex LC LC OM4 2f 30m Cbl QK736A HP Premier Flex LC LC OM4 2f 50m Cbl QK737A QuickSpecs HP 1410 Switch series Configuration DA 13674 Worldwide Version 12 December 16 2013 Page 5 ...

Страница 6: ... C noncondensing Nonoperating Storage temperature 40 F to 158 F 40 C to 70 C Nonoperating Storage relative humidity 15 to 90 149 F 65 C noncondensing Altitude up to 10 000 ft 3 km Acoustic Power 0 dB No fan Electrical characteristics Frequency 50 60 Hz Maximum heat dissipation 41 BTU hr 43 26 kJ hr Voltage 100 240 VAC Current 1 0 A Maximum power rating 12 W Notes Maximum power rating and maximum h...

Страница 7: ...air Onsite UW388E 1 year 6 hour Call To Repair Onsite for hardware HR845E Refer to the HP website at www hp com networking services for details on the service level descriptions and product numbers For details about services and response times in your area please contact your local HP sales office HP 1410 16G Switch J9560A I O ports and slots 16 RJ 45 autosensing 10 100 1000 ports Media Type Auto ...

Страница 8: ...The exact input voltage and frequency rating are determined by the specific power adaptor part number ordered Please select the correct power adaptor country option Safety CSA 22 2 No 60950 UL 60950 1 IEC 60950 1 EN 60950 1 Emissions FCC Rules Part 15 Subpart B Class A Immunity Generic EN 55022 CISPR 22 EN EN 55024 CISPR 24 ESD IEC 61000 4 2 Radiated IEC 61000 4 3 EFT Burst IEC 61000 4 4 Surge IEC...

Страница 9: ...2 3 Type 10BASE T IEEE 802 3u Type 100BASE TX IEEE 802 3ab Type 1000BASE T Supports a maximum of 24 autosensing 10 100 1000 ports Physical characteristics Dimensions 17 32 w x 6 81 d x 1 73 h in 44 x 17 3 x 4 4 cm 1U height Weight 6 61 lb 3 kg Memory and processor 1 MB flash packet buffer size 512 KB Mounting Mounts in an EIA standard 19 inch telco rack hardware included desktop mounting Performan...

Страница 10: ... onsite 13x5 coverage for hardware UF797E 3 year 4 hour onsite 24x7 coverage for hardware UF798E 1 year post warranty 4 hour onsite 13x5 coverage for hardware HR846E 1 year post warranty 4 hour onsite 24x7 coverage for hardware HR847E Installation with minimum configuration system based pricing U4826E Installation with HP provided configuration system based pricing U4830E 4 year 4 hour onsite 13x5...

Страница 11: ...city 48 Gb s MAC address table size 8192 entries Environment Operating temperature 32 F to 104 F 0 C to 40 C Operating relative humidity 15 to 95 104 F 40 C noncondensing Nonoperating Storage temperature 40 F to 158 F 40 C to 70 C Nonoperating Storage relative humidity 15 to 90 149 F 65 C noncondensing Altitude up to 10 000 ft 3 km Acoustic Power 0 dB No fan Electrical characteristics Frequency 50...

Страница 12: ...l to Repair Onsite UW389E 4 Yr 6 hr Call to Repair Onsite UW390E 5 Yr 6 hr Call to Repair Onsite UW391E 1 year 6 hour Call To Repair Onsite for hardware HR848E Refer to the HP website at www hp com networking services for details on the service level descriptions and product numbers For details about services and response times in your area please contact your local HP sales office HP 1410 8 Switc...

Страница 13: ...ower adaptor part number ordered Please select the correct power adaptor country option Safety UL 60950 1 CSA 22 2 60950 1 IEC 60950 1 2005 EN 60950 1 2006 A11 2009 Emissions FCC Rules Part 15 Subpart B Class A Immunity Generic EN 55022 CISPR 22 EN EN 55024 CISPR 24 ESD IEC 61000 4 2 Radiated IEC 61000 4 3 EFT Burst IEC 61000 4 4 Surge IEC 61000 4 5 Conducted IEC 61000 4 6 Power frequency magnetic...

Страница 14: ...3 Mpps 64 byte packets Switching capacity 3 2 Gb s MAC address table size 8192 entries Environment Operating temperature 32 F to 104 F 0 C to 40 C Operating relative humidity 15 to 95 104 F 40 C noncondensing Nonoperating Storage temperature 40 F to 158 F 40 C to 70 C Nonoperating Storage relative humidity 15 to 90 149 F 65 C noncondensing Altitude up to 10 000 ft 3 km Acoustic Power 0 dB No fan E...

Страница 15: ... onsite 24x7 coverage for hardware UR821E 5 year 4 hour onsite 13x5 coverage for hardware UR822E 5 year 4 hour onsite 24x7 coverage for hardware UR823E 3 Yr 6 hr Call to Repair Onsite UW389E 4 Yr 6 hr Call to Repair Onsite UW390E 5 Yr 6 hr Call to Repair Onsite UW391E Refer to the HP website at www hp com networking services for details on the service level descriptions and product numbers For det...

Страница 16: ...eat dissipation are the worst case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE if equipped 100 traffic all ports plugged in and all modules populated The exact input voltage and frequency rating are determined by the specific power adaptor part number ordered Please select the correct power adaptor country option Safety UL 60950 1 CSA 22 2 60950 1 IEC...

Страница 17: ...tact your local HP sales office HP 1410 24 R Switch JD986B I O ports and slots 24 RJ 45 autosensing 10 100 ports Duplex half or full IEEE 802 3 Type 10BASE T IEEE 802 3u Type 100BASE TX Supports a maximum of 24 autosensing 10 100 ports Physical characteristics Dimensions 17 32 w x 6 81 d x 1 73 h in 44 x 17 3 x 4 4 cm Weight 4 41 lb 2 0 kg Memory and processor 8kb EEPROM packet buffer size 2 Mb Mo...

Страница 18: ...C 61000 3 3 Services 3 year 4 hour onsite 13x5 coverage for hardware UF797E 3 year 4 hour onsite 24x7 coverage for hardware UF798E 1 year post warranty 4 hour onsite 13x5 coverage for hardware HR846E 1 year post warranty 4 hour onsite 24x7 coverage for hardware HR847E 4 year 4 hour onsite 13x5 coverage for hardware UR820E 4 year 4 hour onsite 24x7 coverage for hardware UR821E 5 year 4 hour onsite ...

Страница 19: ...04 F 0 C to 40 C Operating relative humidity 15 to 95 104 F 40 C noncondensing Nonoperating Storage temperature 40 F to 158 F 40 C to 70 C Nonoperating Storage relative humidity 15 to 90 149 F 65 C noncondensing Altitude up to 10 000 ft 3 km Acoustic Power 0 dB Electrical characteristics Frequency 50 60 Hz Maximum heat dissipation 37 BTU hr 39 03 kJ hr Voltage 100 240 VAC DC voltage 12 V Current 0...

Страница 20: ...hour onsite 24x7 coverage for hardware UR823E 3 Yr 6 hr Call to Repair Onsite UW389E 4 Yr 6 hr Call to Repair Onsite UW390E 5 Yr 6 hr Call to Repair Onsite UW391E 1 year 6 hour Call To Repair Onsite for hardware HR848E Refer to the HP website at www hp com networking services for details on the service level descriptions and product numbers For details about services and response times in your are...

Страница 21: ...LC LC Multi mode OM4 2 fiber 1m Cable QK732A HP Premier Flex LC LC Multi mode OM4 2 fiber 2m Cable QK733A HP Premier Flex LC LC Multi mode OM4 2 fiber 5m Cable QK734A HP Premier Flex LC LC Multi mode OM4 2 fiber 15m Cable QK735A HP Premier Flex LC LC Multi mode OM4 2 fiber 30m Cable QK736A HP Premier Flex LC LC Multi mode OM4 2 fiber 50m Cable QK737A HP 1410 24G Switch J9561A HP X121 1G SFP LC SX ...

Страница 22: ... 850 1300nm VCSEL Laser sources 600 600 meters 850 1300nm for Gigabit Ethernet compliant links CABLE The cable is duplex zipcord graded index 50 125um multimode optical fiber and designed to work in both the 850 and 1300 nm wavelength windows BULK CABLE CABLE ASSEMBLY CONFIGURATION Jacket Material Riser Grade Low Smoke Zero Halogen thermoplastic Jacket Color Aqua for OM3 multimode per TIA 598 Boot...

Страница 23: ...abit Ethernet compliant links CABLE The cable is duplex zipcord graded index 50 125um multimode optical fiber The cable is designed to work in both the 850 and 1300 nm wavelength windows BULK CABLE CABLE ASSEMBLY CONFIGURATION Jacket Material Riser Grade Low Smoke Zero Halogen thermoplastic Jacket Color Aqua for OM3 multimode per TIA 598 Boot Color White Insertion Loss less than 0 5 dB 850 with LE...

Страница 24: ...abit Ethernet compliant links CABLE The cable is duplex zipcord graded index 50 125um multimode optical fiber The cable is designed to work in both the 850 and 1300 nm wavelength windows BULK CABLE CABLE ASSEMBLY CONFIGURATION Jacket Material Riser Grade Low Smoke Zero Halogen thermoplastic Jacket Color Aqua for OM3 multimode per TIA 598 Boot Color White Insertion Loss less than 0 5 dB 850 with LE...

Страница 25: ...600 meters 850 1300nm for Gigabit Ethernet compliant links CABLE The cable is duplex zipcord graded index 50 125um multimode optical fiber The cable is designed to work in both the 850 and 1300 nm wavelength windows BULK CABLE CABLE ASSEMBLY CONFIGURATION Jacket Material Riser Grade Low Smoke Zero Halogen thermoplastic Jacket Color Aqua for OM3 multimode per TIA 598 Boot Color White Insertion Loss...

Страница 26: ...gabit Ethernet compliant links CABLE The cable is duplex zipcord graded index 50 125um multimode optical fiber The cable is designed to work in both the 850 and 1300 nm wavelength windows BULK CABLE CABLE ASSEMBLY CONFIGURATION Jacket Material Riser Grade Low Smoke Zero Halogen thermoplastic Jacket Color Aqua for OM3 multimode per TIA 598 Boot Color White Insertion Loss less than 0 5 dB 850 with L...

Страница 27: ...gabit Ethernet compliant links CABLE The cable is duplex zipcord graded index 50 125um multimode optical fiber The cable is designed to work in both the 850 and 1300 nm wavelength windows BULK CABLE CABLE ASSEMBLY CONFIGURATION Jacket Material Riser Grade Low Smoke Zero Halogen thermoplastic Jacket Color Aqua for OM3 multimode per TIA 598 Boot Color White Insertion Loss less than 0 5 dB 850 with L...

Страница 28: ...gabit Ethernet compliant links CABLE The cable is duplex zipcord graded index 50 125um multimode optical fiber The cable is designed to work in both the 850 and 1300 nm wavelength windows BULK CABLE CABLE ASSEMBLY CONFIGURATION Jacket Material Riser Grade Low Smoke Zero Halogen thermoplastic Jacket Color Aqua for OM3 multimode per TIA 598 Boot Color White Insertion Loss less than 0 5 dB 850 with L...

Страница 29: ...a please contact your local HP sales office HP Premier Flex LC LC Multi mode OM4 2 fiber 2m Cable QK733A Notes Cable Specs Graded index bendable fiber optic multimode OM3 50 125um duplex cable and Ethernet assembly with LC duplex connectors on each end Core diameter 50um 3um Cladding diameter 125um 2um Coating diameter 245 10um Bandwidth 3000 MHz km 850nm Laser Jacket Color Blue Jacket Material Ri...

Страница 30: ...a please contact your local HP sales office HP Premier Flex LC LC Multi mode OM4 2 fiber 15m Cable QK735A Notes Cable Specs Graded index bendable fiber optic multimode OM3 50 125um duplex cable and Ethernet assembly with LC duplex connectors on each end Core diameter 50um 3um Cladding diameter 125um 2um Coating diameter 245 10um Bandwidth 3000 MHz km 850nm Laser Jacket Color Blue Jacket Material R...

Страница 31: ...a please contact your local HP sales office HP Premier Flex LC LC Multi mode OM4 2 fiber 50m Cable QK737A Notes Cable Specs Graded index bendable fiber optic multimode OM3 50 125um duplex cable and Ethernet assembly with LC duplex connectors on each end Core diameter 50um 3um Cladding diameter 125um 2um Coating diameter 245 10um Bandwidth 3000 MHz km 850nm Laser Jacket Color Blue Jacket Material R...

Страница 32: ...ices for details on the service level descriptions and product numbers For details about services and response times in your area please contact your local HP sales office HP X121 1G SFP LC LX Transceiver J4859C HP X121 1G SFP LC LX Transceiver An SFP format gigabit transceiver with LC connectors using LX technology Ports 1 LC 1000BASE LX port IEEE 802 3z Type 1000BASE LX Duplex full only Physical...

Страница 33: ... 793 2 Type A1b or A1a respectively Maximum distance 2 km full duplex or 412 m half duplex Notes Transmitter wavelength 1310nm Power consumption is 1 1 watt maximum For supported platforms and minimum software requirements to support this product see the document titled Support for the J9054B 100 FX SFP LC Transceiver on the ProCurve Mini GBICs and SFPs Manuals Web page Services Refer to the HP we...

Отзывы: