2560x1600
N/A
60*
NOTE:
Other resolutions may be available but are not recommended as the may not have been tested and qualified by HP
NOTE:
60-R denotes reduced blanking timings are used on single-link DVI connections and may be used with other digital connections
ENVIRONMENTAL INFORMATION
Unit Environment and
Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and
cold, to ensure that unit is operated within the specified operating range.
Leave a 4 in (10.2 cm) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are
subject to each other's re-circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint,
dust and other foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be
provided on the enclosure, and the same operating guidelines listed above will still apply.
Eco-Label Certifications &
declarations
This product has received or is in the process of being certified to the following approvals and may be
labeled with one or more of these marks:
IT ECO declaration This product conforms to the examination standards (2003 version) under JEITA's Label
System.
System Configuration
The configuration used for the Energy Consumption and Declared Noise Emissions data for the Microtower
model is based on a typically configured product
Energy Consumption
115 VAC
230 VAC
100 VAC
Normal Operation
58.2 W
58.86W
57.97 W
Sleep (ENERGY STAR® low
power mode)
1.96 W
1.97 W
1.96 W
Off
0.92 W
0.92 W
0.92 W
NOTE:
Energy efficiency data listed is for an ENERGY STAR® compliant product if offered within the model
family. HP computers marked with the ENERGY STAR® Logo are compliant with the applicable U.S.
Environmental Protection Agency (EPA) ENERGY STAR® specifications for computers. If a model family
does not offer ENERGY STAR® compliant configurations, then energy efficiency data listed is for a typically
configured model.
Heat Dissipation
*
115 VAC
230 VAC
100 VAC
Normal Operation
200 BTU/hr
201BTU/hr
198 BTU/hr
Sleep
7 BTU/hr
7 BTU/hr
7 BTU/hr
Off
3 BTU/hr
3 BTU/hr
3 BTU/hr
NOTE:
Heat dissipation is calculated based on the measured watts, assuming the service level is attained
for one hour.
Declared Noise Emissions
(in accordance with ISO
7779 and ISO 9296)
Typically Configured
Sound Power (LWAd, bels)
Sound Pressure (LpAm, decibels)
Idle
3.6
24
Fixed Disk (random writes)
3.7
26
Longevity and Upgrading
This product can be upgraded, possibly extending its useful life by several years. Upgradeable features
QuickSpecs
HP Pro 3500 Microtower Desktop PC
System Unit Specifications and Environmental Data
DA - 14349 Worldwide — Version 10 — August 8, 2013
Page 13