Chapter 5
Troubleshooting
27
If a Power-On System Hardware Test Error Message Appears
If an error occurs during the power-on system hardware test (when the NetServer
starts) details of the error are displayed. Follow the instructions on the screen.
It is recommended that you correct the error before proceeding, even if the
NetServer appears to start successfully.
If the NetServer starts, but the power-on system hardware test still reports an
error message, clear the CMOS memory, as described below.
Clearing the CMOS Configuration
You may need to clear the CMOS configuration if the configuration has been
corrupted by a program, or if incorrect settings made in the Setup program have
made the display unreadable.
To clear the configuration:
1. Turn off power to the NetServer and remove the cover and the cooling
duct/cover.
2. Move switch 6 on the system board (labeled "Clear CMOS") to the closed
position.
3. Turn on power to the NetServer. A message displays indicating that the
configuration has been cleared.
4. Turn off power to the NetServer.
5. Return switch 6 on the system board to the open position.
6. Replace the cooling duct/cover and the cover.
7. Turn on power to the NetServer. The message
Incorrect PC Configuration
Option ROM error
is displayed.
8. Press [F2] to run the Setup program when
<F2=Setup>
appears.
9. Make any configuration changes that are required.
10. Choose the Exit option and save the changes to save the configuration and
exit the Setup program.
Содержание NetServer E 45
Страница 1: ...HP NetServer E 45 User Guide HP Part Number 5965 2489 Printed August 1997 ...
Страница 40: ......
Страница 52: ......
Страница 72: ......
Страница 84: ......