Electrostatic discharge  15 

Electrostatic discharge 

Preventing electrostatic discharge 

To prevent damaging the system, be aware of the precautions you need to follow when setting up the 
system or handling parts. A discharge of static electricity from a finger or other conductor may damage 
system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the 
device. 
To prevent electrostatic damage: 

 

Avoid hand contact by transporting and storing products in static-safe containers. 

 

Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations. 

 

Place parts on a grounded surface before removing them from their containers. 

 

Avoid touching pins, leads, or circuitry. 

 

Always be properly grounded when touching a static-sensitive component or assembly. 

 

Grounding methods to prevent electrostatic 
discharge 

Several methods are used for grounding. Use one or more of the following methods when handling or 
installing electrostatic-sensitive parts: 

 

Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist 
straps are flexible straps with a minimum of 1 megohm 

±

10 percent resistance in the ground cords. 

To provide proper ground, wear the strap snug against the skin. 

 

Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet 
when standing on conductive floors or dissipating floor mats. 

 

Use conductive field service tools. 

 

Use a portable field service kit with a folding static-dissipating work mat. 

If you do not have any of the suggested equipment for proper grounding, have an authorized reseller 
install the part. 
For more information on static electricity or assistance with product installation, contact an authorized 
reseller. 

Содержание NC550SFP

Страница 1: ...HP NC550SFP Dual Port 10GbE Server Adapter User Guide Part Number 599736 001 February 2010 First Edition ...

Страница 2: ...oducts and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Intended audience This document is for the person who installs administers and troubleshoots servers and storage systems HP assumes you are qualified in the servicing of computer equipment and trained in recognizing haz...

Страница 3: ...ations 11 General specifications 11 Compliance 11 Power and environmental specifications 12 Regulatory compliance notices 13 Regulatory compliance identification numbers 13 Federal Communications Commission notice 13 European Union regulatory notice 13 Canadian notice 14 Korean class A notice 14 Japanese class A notice 14 Disposal of waste equipment by users in private households in the European U...

Страница 4: ...ce the risk of electric shock or damage to the equipment Do not disable the power cord grounding plug The grounding plug is an important safety feature Plug the power cord into a grounded earthed electrical outlet that is easily accessible at all times Unplug the power cord from the power supply to disconnect power to the equipment Do not route the power cord where it can be walked on or pinched b...

Страница 5: ...y us en wwcontact html For HP technical support In the United States for contact options see the Contact HP United States webpage http welcome hp com country us en contact_us html To contact HP by phone o Call 1 800 HP INVENT 1 800 474 6836 This service is available 24 hours a day 7 days a week For continuous quality improvement calls may be recorded or monitored o If you have purchased a Care Pac...

Страница 6: ... supporting teaming for load balancing and failover TCP checksum and segmentation LSO offload capability VLAN tagging jumbo frames IPv6 and other features The NC550SFP can be installed in either standard or low profile slots LED indicators The NC550SFP adapter has two ports with LED indicators for Link L and Activity A for each port Standard height bracket is shown below with the SFP ports and LED...

Страница 7: ...es network activity on the link The adapter is sending or receiving network data at up to 10Gbps Link Off No link to the adapter is established The adapter is not receiving power or the cable connection is faulty On Yellow Link to the adapter is established The adapter is receiving power and the cable connection is good ...

Страница 8: ... instructions for adding and removing user installed components such as PCI PCI X and PCI Express devices Refer to the equipment instructions to verify that it is suitable for user installed components and that it has the power capacity to support all of the installed components NOTE Before removing the cover of your server refer to the HP documentation for the proper methods for installing a PCI ...

Страница 9: ...personal injury from hot surfaces allow the drives and the internal system components to cool before touching them 3 Identify the PCI Express option slot in which the adapter is to be installed If a low profile option slot is to be used install the low profile bracket onto the adapter 4 Remove the cover bracket from the PCI Express slot 5 Firmly seat the adapter in the PCI Express slot and secure ...

Страница 10: ...support either of the following Direct Attached Copper DAC cables Optical Modules to be used with fiber optic cables See Cable specifications on page 11 for the maximum cable length supported To connect the NC550SFP to the network complete the following steps 1 Orient the SFP optical module or DAC cable so that the Gold Fingers on the edge of the circuit board is located closest to the option card...

Страница 11: ...irect Attached Copper DAC cable SFP N A Twin Axial Copper 24 to 28 AWG depending on length and manufacturer N A N A 7 General specifications General specifications Value Controller ServerEngines BE4210 BladeEngine2 Data rate 10Gbps full duplex PCI bus 8 Lane x8 PCI Express Gen 2 compatible with x4 and x8 bus widths Connectors 2 SFP Dimensions LxW 6 6 x 2 7 inches 16 765 cm x 6 89 cm without bracke...

Страница 12: ...cksum Offload IPv4 IPv6 TCP Large Send Offload IPv4 IPv6 TCP Large Receive Offload Receive Side Scaling Jumbo Frames up to 9000 Bytes Power and environmental specifications Power and environmental specifications Value Operating Temperature 0 to 55 C 32 to 131 F Humidity 10 to 90 relative humidity non condensing Non operating Temperature 40 to 70 C 40 to 158 F Humidity 5 to 95 relative humidity non...

Страница 13: ... uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at personal expense European Union regulatory notice This product complies w...

Страница 14: ...his symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal ...

Страница 15: ...tic sensitive component or assembly Grounding methods to prevent electrostatic discharge Several methods are used for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance ...

Страница 16: ...tions CSA Canadian Standards Association DMA direct memory access IEEE Institute of Electrical and Electronics Engineers iSCSI Internet Small Computer System Interface PCI Express Peripheral Component Interconnect Express SFP small form factor pluggable ...

Страница 17: ...4 downloading files 5 E electrostatic discharge 8 15 environmental specifications 12 G grounding methods 15 L LC connector 10 LEDs 6 low profile bracket 9 P PCI peripheral component interface 8 power specifications 12 R regulatory compliance notices 13 14 S specifications 11 12 standards 13 T technical notes 4 V ventilation 4 W warnings 4 Index ...

Отзывы: