![HP N1528A Скачать руководство пользователя страница 68](http://html.mh-extra.com/html/hp/n1528a/n1528a_installation-and-user-manual_165539068.webp)
Troubleshooting
N1528A and N1529A ACL Tape Drive Installation and User’s Guide— 544594-003
6 -8
Fault Symptom Codes (FSCs)
SCSI FIFO Error
1003
D, G
The SCSI controller data FIFO should be
empty but still contains data bytes.
SCSI Gross Error
1004
C, D, G
The SCSI controller detected a gross
error condition - invalid SCSI bus phase
or DMA error.
Illegal SCSI Cnt Cmd
1005
C, D, G
Either an invalid command was sent to
the SCSI controller, or the controller was
not in the correct mode.
SCSI Invalid Element
1007
D, G
Internal SCSI task processing error -
invalid element type was detected.
SCSI Invalid Int.
1009
D, G
The SCSI controller posted an invalid
interrupt status.
Loader Not Ready
2004
C, G
Fail to fetch, stow, scan, move passthru,
Or when loader detects invalid command,
aborts command.
Door Open (status
only)
2009
F
Door is force opened or door sensor
failed.
Cart Inaccessible
200C
F
For an LTO, indicates the tape is not
ejected. Cartridge in drive is not
accessible from changer.
Drive In Error
200D
C, G
A general drive error detected by control
task.
No Magazine
200E
F
Cannot move, element not installed, from
changer.
Removal Prevented
200F
F
Receive medium prevent removal from
drive for a fetch.
Ctl. Firmware Error
2010
C, G
Internal inter task processing error.
Unexpected event. SMX send or receive
error.
Drive Time-out Error
2030
C, G
Cannot communicate with drive.
Drive Code Update
Command Error
2080
C, G
Update code from SCSI or from TAPE
failed.
Move Command
Failure
2081
C, G
Move command from / to drive slot failed,
detected by control task.
Open Mail Slot Fault
2090
C, G
Door open sensor time-out detected when
open door.
Open Left Door Fault
2091
C, G
Door open sensor time-out detected when
open door.
Open Right Door Fault
2092
C, G
Door open sensor time-out detected when
open door.
Table 6-2. Fault Symptom Codes
Message
FSC ERP