MSM323-R Integrated Services Access Point Quickstart 

3

HP ProCurve Networking

WARNING:

The MSM323-R must be installed with the antennas pointing straight up. 
Damage caused by water ingress through the RJ-45 connector as a result 
of the MSM323-R being improperly installed or the improper assembly 
or attachment of the weatherproof RJ-45 connector, is not covered by the 
warranty.

Plan the installation 

Identify a suitable install location. The MSM323-R has a NEMA 4 rating and is unsuitable for 
installation in a salt fog environment. Local electrical and building codes and regional 
regulations will dictate many aspects of your installation. You may also wish to perform 
transmission and reception tests at a proposed location before installing. In some cases it 
may be desirable to install remote antennas, off the body of the MSM323-R.

You will have to provide an effective earth ground for the MSM323-R, at least one of its 
antenna surge suppressors, and the Ethernet surge suppressor. It is rarely sufficient to use a 
metal pole for any equipment grounding.

You will also need to decide how to route the Ethernet cable from the building to the 
MSM323-R.

Install Cabling

According to your needs and local electrical codes and regulations, run grounding wires and 
Ethernet cable to where the MSM323-R will be installed.

Ensure that the other end of the grounding wires connect to a true earth ground according to 
the NFPA 70 National Electrical Code and/or all pertinent local codes.

For the Ethernet cable, allow for an extra two feet (.6 meters) for connector attachment and 
drip loops. In addition, allow for an extra four feet (1.2 meters) of cable for the Ethernet 
surge suppressor. Use outdoor-rated shielded Cat5e cable (direct-burial type recommended).

Prepare the weatherproof Ethernet cable

To provide a weatherproof seal, the Ethernet port on the MSM323-R uses a custom 
weatherproof cable connector (supplied). You must terminate your Ethernet cable with this 
connector as described in the following procedure. Cable length should not exceed 300 feet 
(91 meters).

Caution:

Ruggedized and shielded Ethernet cables must be used for all connections. 

1.

Carefully unpack the nine quick-disconnect items from the plastic bag, identifying all 
parts as illustrated. If any parts are missing, DO NOT proceed until you get a 
replacement parts kit.

2.

If your Cat5 Ethernet cable already has an RJ-45 connector on the end that will connect 
to the HP ProCurve equipment, remove the RJ-45 connector by cutting the cable at least 
half an inch (1.2 cm) before the RJ-45 connector.

Be sure to make a clean cut with a pair of sharp angle cutters. 

The complete cut 

(through both the cable sheath and all wires) must occur in a single cutting motion.

3.

Hold Clamp Ring (C) horizontally, with its fingers to the left. Insert the Seal (B) into the 
fingers on the left end so that it is flush with the end of the fingers. Insert the Gasket (D) 
into the right end, pushing it against the ridge at the end of the threads. The Gasket is 
beveled on one side. The beveled side should face inwards away from the Screw Nut.

4.

Thread the Sealing Nut (A) onto the left end of the Clamp Ring (C). Tighten it only 
enough for it to stay attached.

5.

Hold the Screw Nut (E) vertically, with the open threads facing up, and drop the Body (f) 
into it, with the RJ-45 connector opening facing up.

6.

Hold the Clamp Ring (C) vertically below the Screw Nut/Body items and screw the Body 
into the threads on the Clamp Ring (C). Tighten it only enough to stay attached. Note 
that the Screw Nut (E) remains loose on the Body (F).

7.

Remove the white backing paper from one of the RJ-45 Gaskets (H) and press the glued 
side onto the Body (F) being 

very careful

 to align the gasket with the RJ-45 connector 

shape on the Body (F).

8.

Remove the backing paper from the second RJ-45 Gasket (H) and press it over the first 
one, being sure to maintain alignment.

9.

Tighten the threads between Body (F) and Clamp Ring (C)

 by hand. DO NOT tighten 

between Clamp Ring (C) and Sealing Nut (A). Do not over tighten. Do not tighten with 
tools.

The quick-disconnect assembly should now look like this when held horizontally, with 
the Sealing Nut (A) at the left end, and the Screw Nut (E) over the Body (F) at the right 
end.

10.

Carefully thread the cleanly-cut end of the Cat5 Ethernet cable through the Sealing Nut 
(A) end of the quick-disconnect assembly, and push through approximately 1 foot (30 
cm) of cable.

Note:

The next two steps should be performed by someone with experience building 
Ethernet cables.

11.

Prepare the cable and attach it to the RJ-45 Plug (G) according to the directions 
included with your crimping tool.

12.

Before continuing, test the cable with a portable Ethernet cable tester to ensure that the 
RJ-45 plug (G) is correctly connected.

Sealing

Nut

Seal

Clamp

Ring

Screw

Nut

RJ45

Plug

Gasket

Body

RJ45

Gaskets

A

B

C

D

E

F

G

H

Weatherproof connector parts

Содержание MSM323-R

Страница 1: ...ess VIEW Certification Program VIEW Certified MSM323 R Integrated Services Access Point Quickstart This Quickstart introduces the MSM323 R US J9342A WW J9345A Integrated Services Access Point formerly the MSC 3300R MultiService Controller and shows you how to get started using it After following the directions in this Quickstart see the MSC 3000 Series Admin Guide available at www procurve com cus...

Страница 2: ...lure to do so may result in personal injury fire equipment damage or a voided warranty The HP ProCurve hardware warranty provides no protection against damage caused by static discharge or a lightning strike Cabling You must use the appropriate cables and where applicable surge protection for your given region For compliance with EN55022 Class B emissions requirements use shielded Ethernet cables ...

Страница 3: ...t parts kit 2 If your Cat5 Ethernet cable already has an RJ 45 connector on the end that will connect to the HP ProCurve equipment remove the RJ 45 connector by cutting the cable at least half an inch 1 2 cm before the RJ 45 connector Be sure to make a clean cut with a pair of sharp angle cutters The complete cut through both the cable sheath and all wires must occur in a single cutting motion 3 H...

Страница 4: ...own the Ethernet cable and into the connector Form the loop as shown here Make sure that the distance between the loop start and end points is at least 6 inches 15 cm and that the cable hangs down at least 10 inches 25 cm 6 Refer to illustration Weatherproof connector parts on previous page Mate the RJ 45 Plug G with the socket on the MSM323 R hold it firmly in place and tighten the Screw Nut E by...

Страница 5: ...mpt appears If it does select the country in which this product will be used and select Save WARNING The country must be set accurately to the country in which the MSM323 R will operate 7 At the password prompt it is recommended that you change the password Specify the new password and select Save Note Passwords must contain at least six characters including four different characters Management to...

Страница 6: ...ned in step E 2 above 2 Connect your computer to the same network as the MSM323 R 3 Look in the DHCP server log for the Ethernet Base MAC address shown on the MSM323 R label and take note of the corresponding IP address 4 Relaunch the MSM323 R management tool this time using https IP address discovered in previous step to continue configuring the MSM323 R Assigning an IP address The Internet port ...

Отзывы: