background image

Service and Support

Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of hard drives,
memory and processors). The warranty is fully supported by HP Services and a worldwide network of resellers and
service providers. In addition 90-day's getting started software telephone support may be covered under the
warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack
services.

NOTE: Limited warranty includes 3 year parts, 3 year labor, 3-year on-site support

Care Pack services provide a range of life cycle support options that let you choose the service levels that meet
your business requirements, from basic to mission-critical.

A full range of HP Care Pack hardware and software services are available including:

Installation and start up
Education courses
Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7 days call
window with options including 4-hour response or 6-hour Call To Repair
Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and VMWare-
based IT solutions helping to deliver high level of application availability. Response times range from 30 mins
for critical problems to 2 hours.
System Management, Performance Services and Mission Critical Support Solution

HP Care Pack Services include HP branded hardware options qualified for the server, purchased at the same time or
afterwards, internal to the enclosure, as well as 22" and smaller external monitors and tower UPS options up to
3KVA. 22" and smaller external monitors will be covered at the same service level and coverage period as the
server. For servers or storage systems installed within a rack, service also covers all HP qualified rack options
installed within the same rack.

NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or resellers or
visit our worldwide Web site on the internet at: 

http://www.hp.com/hps/carepack

NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us at:

http://www.hp.com/hps

NOTE: Additional information regarding worldwide limited warranty and technical support is available at:

http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html

QuickSpecs

HP ProLiant ML530 Generation 2 (G2)

Standard Features

DA - 11359   Worldwide — Version 48 — September 24, 2004

Page 9

Содержание ML530 - ProLiant - 128 MB RAM

Страница 1: ...even PCI X slots 8 Memory Board 1 Rack Handles 2 1 44MB Diskette Drive 3 High Speed IDE CD ROM 4 Diagnostic Lighting 5 Wide Ultra3 Ultra320 Hot Plug Drive Bays 12 x 1 Standard 6 5 25 inch Removable Media Bays What s New Intel Xeon 3 0GHz Processors with 400MHz system bus QuickSpecs HP ProLiant ML530 Generation 2 G2 Overview DA 11359 Worldwide Version 48 September 24 2004 Page 1 ...

Страница 2: ...x 300 GB 1 hot plug drives with optional ML5xx Internal Two Bay Hot Plug SCSI Drive Cage with fan Advanced Memory Protection including Mirrored Memory and Online Spare Memory 600 Watt Hot Plug Power Supply with optional 1 1 redundancy Hot Plug System Fans with optional redundancy Embedded NC3163 Fast Ethernet NIC PCI 10 100 WOL Wake On LAN and PXE support Integrated Dual Channel Wide Ultra3 SCSI A...

Страница 3: ...B Network Controller Embedded NC3163 Fast Ethernet NIC PCI 10 100 with full WOL Wake On LAN and PXE support Expansion Slots Bus Speed Bus Number Hot Plug PCI Voltage Notes 1 64 bit 100MHz PCI X 1 Yes 3 3V 2 64 bit 100MHz PCI X 1 Yes 3 3V SA6402 6404 not recommended 3 64 bit 100MHz PCI X 5 Yes 3 3V 4 64 bit 100MHz PCI X 5 Yes 3 3V 5 64 bit 100MHz PCI X 9 No 3 3V 6 64 bit 100MHz PCI X 9 No 3 3V 7 64...

Страница 4: ...ional information regarding USB support http h18004 www1 hp com products servers platforms usb support html External SCSI 1 Graphics Integrated Rage XL Video Controller with 8 MB SDRAM Video Memory Form Factor Tower or Rack 7U QuickSpecs HP ProLiant ML530 Generation 2 G2 Standard Features DA 11359 Worldwide Version 48 September 24 2004 Page 4 ...

Страница 5: ...s automatic delivery of software and driver change notifications for ProLiant products Sign up at http www hp com go subscriberschoice and customize your profile to receive various new alerts as they become available on a weekly or monthly basis ROMPaq support software and configuration utilities The latest software drivers and firmware fully optimized and tested for your ProLiant server and optio...

Страница 6: ...provides a higher level of availability than Advanced ECC and Online Spare Memory because it protects against multi bit errors Single board Mirrored Memory uses a single memory board that is configured with a mirrored redundant set of memory The system writes to both sets of memory but reads from one If a memory bank has a multi bit error or full DIMM failure the system simply reads from the mirro...

Страница 7: ... OS Support Microsoft Windows NT Server Microsoft Windows NT Enterprise Edition Microsoft Windows 2000 Windows Server 2003 Novell NetWare SCO UnixWare LINUX Red Hat SuSE Sun Solaris Intel Platform Edition Caldera OpenUnix OS 2 e Business NOTE For a more complete and up to date listing of supported OS s and versions please visit our OS Support Matrix at http www hp com go supportos NOTE For an up t...

Страница 8: ...ducts servers ProLiantml530 index html Installation of HP servers into Third Party Round Hole Racks If a Third Party rack is used an additional rack kit will need to be used with the rack kit that comes with the server The additional rack kit part number is Compaq part number 274739 B21 The rack kit comers with all necessary brackets hardware and installation instructions NOTE Third party square h...

Страница 9: ...ials and VMWare based IT solutions helping to deliver high level of application availability Response times range from 30 mins for critical problems to 2 hours System Management Performance Services and Mission Critical Support Solution HP Care Pack Services include HP branded hardware options qualified for the server purchased at the same time or afterwards internal to the enclosure as well as 22...

Страница 10: ... 44 MB Diskette Drive Form Factor Tower ML530T02 X3 0 512KB 1024MB 2P 271245 xx1 Processor Two Intel Xeon 3 0 GHz Processor standard Processor System Bus 400 MHz system bus Processor Memory 512 KB level 2 cache per processor Memory 1024 MB Standard 16 384 MB Maximum PC1600 Advanced ECC SDRAM 2 1 interleaved memory NOTE Maximum memory achieved using 2048 MB DIMMs Network Controller Embedded NC3163 ...

Страница 11: ... 44 MB Diskette Drive Form Factor Tower ML530T02 X2 80 512KB 1024MB 2P 306489 xx1 Processor Two Intel Xeon 2 80 GHz Processor standard Processor System Bus 400 MHz system bus Processor Memory 512 KB level 2 cache per processor Memory 1024 MB Standard 16 384 MB Maximum PC1600 Advanced ECC SDRAM 2 1 interleaved memory NOTE Maximum memory achieved using 2048 MB DIMMs Network Controller Embedded NC316...

Страница 12: ...44 MB Diskette Drive Form Factor Tower ML530T02 X2 40 512KB 1024MB 2P 226608 xx1 Processor Two Intel Xeon 2 40 GHz Processors standard Processor System Bus 400 MHz system bus Processor Memory 512 KB level 2 cache per processor Memory 1024 MB Standard 16 384 MB Maximum PC1600 Advanced ECC SDRAM 2 1 interleaved memory NOTE Maximum memory achieved using 2048 MB DIMMs Network Controller Embedded NC316...

Страница 13: ...4 MB Diskette Drive Form Factor Rack 7U ML530R02 X3 0 512KB 1024MB 2P 271246 xx1 Processor Two Intel Xeon 3 0 GHz Processor standard Processor System Bus 400 MHz system bus Processor Memory 512 KB level 2 cache per processor Memory 1024 MB Standard 16 384 MB Maximum PC1600 Advanced ECC SDRAM 2 1 interleaved memory NOTE Maximum memory achieved using 2048 MB DIMMs Network Controller Embedded NC3163 ...

Страница 14: ...4 MB Diskette Drive Form Factor Rack 7U ML530R02 X2 80 512KB 1024MB 2P 306490 xx1 Processor Two Intel Xeon 2 80 GHz Processor standard Processor System Bus 400 MHz system bus Processor Memory 512 KB level 2 cache per processor Memory 1024 MB Standard 16 384 MB Maximum PC1600 Advanced ECC SDRAM 2 1 interleaved memory NOTE Maximum memory achieved using 2048 MB DIMMs Network Controller Embedded NC316...

Страница 15: ... 2 40 GHz Processors standard Processor System Bus 400 MHz system bus Processor Memory 512 KB level 2 cache per processor Memory 1024 MB Standard 16 384 MB Maximum PC1600 Advanced ECC SDRAM 2 1 interleaved memory NOTE Maximum memory achieved using 2048 MB DIMMs Network Controller Embedded NC3163 Fast Ethernet NIC PCI 10 100 with WOL Wake On LAN Storage Controller Integrated Dual Channel Wide Ultra...

Страница 16: ...sentials Intelligent Networking Pack Flex License 372950 B21 ProLiant Essentials Intelligent Networking Pack Track License 372951 B21 NOTE Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs Refer to http www hp com servers proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information NOTE For more information regar...

Страница 17: ...o U2 or U3 speeds U320 drives require an optional U320 Smart Array Controller or U320 SCSI HBA to support U320 transfer rates NOTE Please see the Hard Drive QuickSpecs for Technical Specifications such as capacity height width interface transfer rate seek time physical configuration and operating temperature U320 Hard Drive QS http h18000 www1 hp com products quickspecs 11531_div 11531_div HTML Wo...

Страница 18: ...r 268351 B21 Ultra320 Expansion Module for SA 6402 273911 B21 64 Bit 66 MHz Dual Channel Wide Ultra3 SCSI Adapter Alternate OS 284688 B21 NOTE Please see the following Controller or SCSI Adapter QuickSpecs for Technical Specifications such as PCI Bus PCI Peak Data Transfer Rate SCSI Protocols supported SCSI Peak Data Transfer Rate Channels SCSI Ports Drives supported Cache RAID support and additio...

Страница 19: ...n a 3U rack mount kit 350544 B21 HP StorageWorks Ultrium 215 Array Module Carbon Offline hot swap drive for Tape Array 5300 C7492B HP StorageWorks Ultrium 230 Tape Drive Internal Carbon NOTE When purchasing this internal drive a cooling fan also needs to be ordered The fan kit part number is 344257 B21 and comes with installation instructions to install inside the server Q1515A HP StorageWorks Ult...

Страница 20: ...prions http h18006 www1 hp com products quickspecs 11403_div 11403_div HTML Worldwide http h18006 www1 hp com products quickspecs 11403_na 11403_na HTML North America For an up to date listing of the latest O S and software support details for the DLT VS80 please visit http www hp com go connect Internal External and Rack mount SDLT Tape Drives HP StorageWorks SDLT 320 Tape Drive Internal Carbon W...

Страница 21: ...1878_div 11878_div HTML Worldwide http h18000 www1 hp com products quickspecs 11878_na 11878_na HTML North America Accessories for 3U 5U Rack mount Tape Drive Kits LVD Cable Kit VHDCI HD68 NOTE For use with the 3U Rack mount Kit and 5U Rack mount Kit only 168048 B21 LVD Cable Kit HD68 HD68 NOTE For use with the 3U Rack mount Kit and 5U Rack mount Kit only 242381 B21 Accessories for 3U 5U Rack moun...

Страница 22: ...ation needed to create a complete solution reference current compatibility information at http www hp com go ebs HP StorageWorks SSL1016 Tape Autoloader SSL1016 Ultrium 460 Tape Autoloader 330821 B21 SSL1016 SDLT 320 Tape Autoloader 330816 B21 NOTE Please reference the SSL1016 Tape Autoloader QuickSpecs at http www hp com go automation for additional information needed to create a complete solutio...

Страница 23: ... with embedded FC router 301897 B25 MSL5030 1 drive 30 slots Ultrium 230 TT 301898 B21 MSL5030 2 drive 30 slots Ultrium 230 TT 301898 B22 NOTE Please reference the MSL5030 Tape Library QuickSpecs at http www hp com go automation for additional information needed to create a complete solution reference current compatibility information at http www hp com go ebs HP StorageWorks MSL5060 Tape Library ...

Страница 24: ...p com go optical for additional information needed to create a complete solution HP StorageWorks 9 1 GB Mid range Optical Jukeboxes 300mx 2 drive 32 slot jukebox C1150M 600mx 4 drive 64 slot jukebox C1160M 700mx 2 drive 76 slot jukebox C1170M NOTE Please reference the Magneto Optical Jukebox data sheets at http www hp com go optical for additional information needed to create a complete solution H...

Страница 25: ... go MSA1500cs HP StorageWorks Modular Smart Array 1000 HP StorageWorks Modular Smart Array 1000 201723 B22 NOTE Please see the Modular Smart Array 1000 QuickSpecs for additional options and configuration information at http h18000 www1 hp com products quickspecs 11033_na 11033_na HTML North America http h18000 www1 hp com products quickspecs 11033_div 11033_div HTML Worldwide StorageWorks Options ...

Страница 26: ... may also be used to connect to the low volt model of the UPS R3000 XR HP Modular Power Distribution Units mPDU High Volt Model 24A 200 240 VAC NA Japan 252663 D72 NOTE L6 30 input HP Modular Power Distribution Units mPDU High Volt Model 32A 200 240 VAC Int l 252663 B31 HP Modular Power Distribution Units mPDU High Volt Model 40A 200 240 VAC WW 252663 B21 NOTE The 40A model has a hardwired input H...

Страница 27: ...KD POL ABE SP AKL THAI ABF FR AKN BHCSY ABH NL AKR SLOV ABJ Japan ARK ICELAND ABM LA B15 KAZ ABN NOR UUZ SWISS ABS SW Custom Builder Please see the Enterprise Configurator for configuration assistance at http www hp com products configurator Rack Conversion Kit ProLiant ML5xx G2 Tower to Rack Conversion Kit 253699 B21 ProLiant ML5xx G2 Rack to Tower Conversion Kit 271258 B21 QuickSpecs HP ProLiant...

Страница 28: ...s please see the following URL http h18000 www1 hp com products servers proliantstorage racks index html Rack Options for HP Rack 10000 Series HP Rack Light Kit Neon 361589 B21 HP Rack Plinth Kit Carbon 251960 B21 42U Side Panel Graphite Metallic 246099 B21 36U Side Panel Graphite Metallic 246102 B21 47U Side Panel Graphite Metallic 255486 B21 NOTE For additional information regarding Rack Options...

Страница 29: ...1 UK XX 101 Sweden Finland XX 041 Germany XX 111 Switzerland XX 051 France XX 131 Portugal XX 061 Italy XX 181 Belgium XX 071 Spain XX 291 Japan XX 081 Denmark XX B31 International NOTE For additional information regarding Rack Options please see the following URL http h18000 www1 hp com products servers proliantstorage rack options index html Rack Options for Third Party Cabinet Racks Rack Adapte...

Страница 30: ...r Intent plus customer defined cable management and naming convention customer furnished image download IP addressing cluster configurations SQL External storage RAID Quick restore creation cd duplication test reports real time reporting of server MAC address password RILOE Customer access and validation through VPN price rack NOTE Available on ProLiant rack models only Factory Express Rack Integr...

Страница 31: ...Level 9x5 4 hour H W 9x5 2 hour O S NT NetWare 3 Years 6 3 Part Number for EMEA 179836 022 9 x 5 HW 4 hr response Next Available HW engineer 9 x 5 Bronze Software Support 2 hr response for Windows NT Windows 2000 Professional Server or Advanced Server Operating System Next Available Specialist 2 5 2 Part Number for Canada FM M01E3 36 9 x 5 HW 4 hr response Next Available HW engineer 9 x 5 Bronze S...

Страница 32: ... response critical 1 hr response non critical for Windows NT Windows 2000 Professional Server or Advanced Server Operating System Technical Account Manager Technical Newsletter SW activity review proactive revision management Upgrade impact planning 2 System Healthcheck per year 6 3 Part Number for U S 239944 002 24 x 7 HW 4 hr response Named HW engineer 24 x 7 Gold Subsequent System Support for W...

Страница 33: ...se critical 1 hr response non critical for Novell NetWare Operating System Technical Account Manager Technical Newsletter SW activity review Upgrade impact planning 2 5 2 Part Number for Canada FM N09E3 36 24 x 7 HW 2 hr response Named HW engineer 24 x 7 Gold Software Support 30 minute response critical 1 hr response non critical for Novell NetWare Operating System Technical Account Manager Techni...

Страница 34: ...2048 MB 2048 MB 2048 MB 2048 MB 2048 MB 2048 MB 2048 MB Optional Compaq Advanced Memory Protection Configurations NOTE Online Spare Memory Bank D is the Online Spare Bank Mirrored Memory Bank C mirrors Bank A Bank D mirrors Bank B NOTE This chart does not represent all possible memory configurations Bank A Bank B Bank C Bank D Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Online 2560 MB ...

Страница 35: ...ilable half height bays for tape backup DVD SCSI storage or optional ML5xx Internal Two Bay Hot Plug Wide SCSI Drive Cage with fan Drive Support Quantity Supported Position Supported Controller Removable Media 1 44 MB Diskette Drive Up to 1 A Integrated IDE CD ROM Drive Up to 1 B Integrated IDE DVD ROM Drive Option Kit Up to 1 B C D Integrated IDE ML5xx Internal Two Bay Hot Plug Wide SCSI Drive Ca...

Страница 36: ...ay 1000 Please see the Modular Smart Array 1000 QuickSpecs below to determine configuration requirements External Please see the Modular Smart Array 1000 QuickSpecs URL below for the latest list of supported HBAs Modular Smart Array 1500 cs Please see the Modular Smart Array 1500 QuickSpecs below to determine configuration requirements External Please see the Modular Smart Array 1500 cs QuickSpecs...

Страница 37: ...pter 64 Bit 133Mhz Dual Channel Ultra320 SCSI Adapter 64 Bit 66 MHz Dual Channel Wide Ultra3 SCSI Adapter Alternate OS Ultrium 215 External Ultrium 230 External Ultrium 460 External Up to 2 External Integrated Dual Channel Wide Ultra3 Adapter 64 Bit 133Mhz Dual Channel Ultra320 SCSI Adapter 64 Bit 66 MHz Dual Channel Wide Ultra3 SCSI Adapter Alternate OS HP StorageWorks DAT 72 Tape Drive External ...

Страница 38: ...e configuration requirements External 64 Bit 133Mhz Dual Channel Ultra320 SCSI Adapter 64 Bit 66 MHz Dual Channel Wide Ultra3 SCSI Adapter Alternate OS ESL Extended 712e ESL Extended 630e ESL9322 ETLA ESL9595 ETLA Please reference the ESL E Series and ESL9000 Series Tape Libraries QuickSpecs to determine configuration requirements External 64 Bit 133Mhz Dual Channel Ultra320 SCSI Adapter 64 Bit 66...

Страница 39: ...lly Loaded System Input Wattage W 902 888 875 862 850 838 Fully Loaded System Input Current A rms 9 2 7 9 4 3 4 0 3 8 3 6 Fully Loaded System Thermal BTU Hr 3076 3029 2984 2940 2898 2856 Fully Loaded System VA Volt Amp 920 906 893 880 867 855 Power cord requirements Nema 5 15P to IEC320 C13 Option no Spare no See Power Cord chart IEC320 C13 to IEC320 C14 Option no Spare no 142259 001 142258 B21 NO...

Страница 40: ...614 003 Australia 100611 007 Europe 100614 003 France 100614 003 Germany 100614 003 Japan 139867 006 PRC 139867 006 PRC 100613 003 PRC 100661 007 UK 100613 003 US 163719 002 QuickSpecs HP ProLiant ML530 Generation 2 G2 Power Specifications DA 11359 Worldwide Version 48 September 24 2004 Page 40 ...

Страница 41: ...ndom Seeks to Fixed Disks L WAd BELS 7 1 System Unit Rack Dimensions HxWxD 12 8 x 17 5 x 25 6 in 32 5 x 44 4 x 65 0 cm Weight approximate 100 lb 45 36 kg No hard drives installed one power supply Input Requirements per power supply Range Input Voltage 100 to 127 VAC 200 to 240 VAC Rated Input Frequency 47 to 63 Hz Input Power 690W 110 VAC Rated Input Current 7 6A BTU Rating 2400 BTU hr SCSI Connec...

Страница 42: ...5 x 8 11 in 4 29 x 14 86 x 20 60 cm Weight 2 09 lb 0 95 kg Integrated Dual Channel Wide Ultra3 SCSI Adapter Drives Supported Up to 15 SCSI devices per channel Data Transfer Method 64 bit PCI bus master SCSI Channel Transfer Rate 160 MB s per channel Maximum Transfer Rate per PCI Bus peak 267 MB s SCSI Termination Active Termination SCSI Connectors 1 external 2 internal 68 pin Compaq NC3163 Fast Et...

Страница 43: ... Intel Corporation The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein QuickSpecs HP ProLiant ML530 Generation 2 G2 Technical Specifications DA 11359 Wor...

Отзывы: