Diagnostics and troubleshooting
e.
Enter one of the following commands and press
Enter
to establish communications with the switch
using Telnet.
telnet
xxx.xxx.xxx.xxx
or
telnet
switchname
where
xxx.xxx.xxx.xxx
is the switch IP address and
switchname
is the switch name associated with
the IP address.
f.
Enter an account name and password, and press
Enter
after the Telnet window opens and prompts
you for a login. The default account name is
admin
. The default password is
password
.
g.
Enter the following command and press
Enter
to open an admin session to acquire the necessary
authority.
McDATA4GbSAN $>admin start
h.
Enter the following command and press
Enter
to restore the configuration file. When the restore is
complete, the switch will reset.
McDATA4GbSAN (admin) $>config restore
Over temperature blink pattern
An over temperature blink pattern is 5 blinks followed by a two second pause. The 5-blink error pattern
indicates that the air temperature inside the switch has exceeded the failure temperature threshold. The
failure temperature threshold is 70° C.
If the Heartbeat LED shows the over temperature blink pattern, consider the ambient air temperature. Make
necessary corrections. If the condition remains, power down the switch and contact your authorized
maintenance provider.
Logged-in LED diagnostics
Port diagnostics are indicated by the Logged-in LED for each port as shown in
.
Figure 13
Logged-in LED diagnostics
The Logged-in LED has three indications:
•
Continuous illumination—A device is logged in to the port.
•
Flashing once per second—Another switch is logging in to the port, or the port is administratively
offline.
•
Flashing twice per second—The port is down or an error has occurred.
2 seconds
Logged-in LEDs