ProCurve Switch 4100gl Series
9
Environment
Operating temperature
32ºF to 131ºF (0ºC to 55ºC)
32ºF to 131ºF (0ºC to 55ºC)
32ºF to 131ºF (0ºC to 55ºC)
Operating relative humidity
15% to 95% @ 104ºF (40ºC),
non-condensing
15% to 95% @ 104ºF (40ºC),
non-condensing
15% to 95% @ 104ºF (40ºC),
non-condensing
Non-operating/Storage
temperature
-40ºF to 158ºF (-40ºC to 70ºC)
-40ºF to 158ºF (-40ºC to 70ºC)
-40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/Storage relative
humidity
15% to 95% @ 149ºF (65ºC),
non-condensing
15% to 95% @ 149ºF (65ºC),
non-condensing
15% to 95% @ 149ºF (65ºC),
non-condensing
Altitude
up to 15091 ft. (4.6 km)
up to 15091 ft. (4.6 km)
up to 15091 ft. (4.6 km)
Electrical characteristics
Maximum heat dissipation
2152 BTU/hr (2270.36 kJ/hr)
2152 BTU/hr (2270.36 kJ/hr)
2152 BTU/hr (2270.36 kJ/hr)
Voltage
100-127 / 200-240 VAC
100-127 / 200-240 VAC
100-127 / 200-240 VAC
Current
8.2 / 3.8 A
8.2 / 3.8 A
8.2 / 3.8 A
Power consumption
630 W
630 W
630 W
Frequency
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
Safety
cUL (CSA 950); EN 60950/IEC
60950; NOM-019-SCFI-1994; UL
1950 3rd edition
cUL (CSA 950); EN 60950/IEC
60950; NOM-019-SCFI-1994; UL
1950 3rd edition
cUL (CSA 950); EN 60950/IEC
60950; NOM-019-SCFI-1994; UL
1950 3rd edition
Emissions
FCC Class A; VCCI Class A; EN
55022/CISPR 22 Class A
FCC Class A; VCCI Class A; EN
55022/CISPR 22 Class A
FCC Class A; VCCI Class A; EN
55022/CISPR 22 Class A
Immunity
EN
EN 55024, CISPR 24
EN 55024, CISPR 24
EN 55024, CISPR 24
ESD
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated
IEC 61000-4-3; 3 V/m
IEC 61000-4-3; 3 V/m
IEC 61000-4-3; 3 V/m
EFT/Burst
IEC 61000-4-4; 1.0 kV (power
line), 0.5 kV (signal line)
IEC 61000-4-4; 1.0 kV (power
line), 0.5 kV (signal line)
IEC 61000-4-4; 1.0 kV (power
line), 0.5 kV (signal line)
Surge
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-5; 1 kV/2 kV AC
Conducted
IEC 61000-4-6; 3 V
IEC 61000-4-6; 3 V
IEC 61000-4-6; 3 V
Power frequency magnetic field
IEC 61000-4-8; 1 A/m, 50 or 60
Hz
IEC 61000-4-8; 1 A/m, 50 or 60
Hz
IEC 61000-4-8; 1 A/m, 50 or 60
Hz
Voltage dips and interruptions
IEC 61000-4-11; >95% reduction,
0.5 period, 30% reduction, 25
periods
IEC 61000-4-11; >95% reduction,
0.5 period, 30% reduction, 25
periods
IEC 61000-4-11; >95% reduction,
0.5 period, 30% reduction, 25
periods
Harmonics
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3
EN 61000-3-3, IEC 61000-3-3
EN 61000-3-3, IEC 61000-3-3
Management
ProCurve Manager Plus; ProCurve
Manager (included);
command-line interface; Web
browser; configuration menu;
out-of-band management (serial
RS-232C)
ProCurve Manager Plus; ProCurve
Manager (included);
command-line interface; Web
browser; configuration menu;
out-of-band management (serial
RS-232C)
ProCurve Manager Plus; ProCurve
Manager (included);
command-line interface; Web
browser; configuration menu;
out-of-band management (serial
RS-232C)