HP-UX revision
HP- UX 11i version 2
Windows revision
Windows Server 2003, Datacenter Edition for Itanium 2.
Linux revision
Red Hat RHEL AS 3 Update 3 / SUSE SLES 9
Linux revision on Superdome with Intel Itanium 2 processors only (not on
Superdome with mx2 processor modules)
Expandability / Connectivity
Expandability / Connectivity
Expandability / Connectivity
Expandability / Connectivity
12 slot PCI X I/O chassis
Note: SPU cabinet must
be filled first before
placing I/O chassis
in I/O expansion cabinet
1 - 4
No I/O expansion
cabinet needed
1 - 8
I/O expansion cabinet
required if number of I/O
chassis is more greater
than 4.
1 - 16
I/O expansion cabinet
required if number of I/O
chassis is greater than 8.
A second I/O expansion
cabinet is required if the
number of I/O chassis is
greater than 14.
Number of Partitions
without I/O expansion
cabinet
1 - 4
1 - 4
1 - 8
Number of Partitions with
I/O expansion cabinet
Not Applicable
1 - 8
1- 16
RS 232C Serial Ports
Yes
Yes
Yes
10/100Base T Ethernet
Yes
Windows does not
support 10/100 Base T
Ethernet. Windows
requires Gigabit Ethernet
card
Yes
Windows does not
support 10/100
Base T Ethernet. Windows
requires
Gigabit Ethernet card
Yes
Windows does not
support 10/100 Base T
Ethernet. Windows
requires Gigabit Ethernet
card
Maximum I/O Cards See supported I/O table for specific products
Maximum I/O Cards See supported I/O table for specific products
Maximum I/O Cards See supported I/O table for specific products
Maximum I/O Cards See supported I/O table for specific products
Mass Storage
16 - 48
16 - 96
16 - 1 92
LAN
2 - 32
2 - 48
2 - 96
WAN
8
16
32
Multi-Function (Mass
Storage / LAN)
8 - 48
16 -96
32 -192
Additional Interface
Cards
8
8 -14
8 -14
Typical Electrical Characteristics by Configuration
Typical Electrical Characteristics by Configuration
Typical Electrical Characteristics by Configuration
Typical Electrical Characteristics by Configuration
AC input power
200 240 VAC, 50/60 Hz 200 240 VAC, 50/60 Hz 200 240 VAC, 50/60 Hz
Typical Input Power
(watts)
dissipation Itanium 2
(watts)
5,900
4 cells, 32 GB, 4 I/O
chassis with 6 PCI each
9,800
8 cells, 32 GB, 4 I/O
chassis with
6 PCI each
19,600
16 cells, 32 GB, 4 I/O
chassis with
6 PCI each
Typical power dissipation
mx2 (watts)
5,730
9,490
18,980
Typical 3 Phase 4Wire
Current requirements at
200V 240V
17A / Phase
29A / Phase
Two Cabinets 29A /
Phase
QuickSpecs
HP Integrity Superdome Servers 16-socket, 32-socket,
HP Integrity Superdome Servers 16-socket, 32-socket,
HP Integrity Superdome Servers 16-socket, 32-socket,
HP Integrity Superdome Servers 16-socket, 32-socket,
and 64-socket
and 64-socket
and 64-socket
and 64-socket
Technical Specifications
DA - 11717 Worldwide — Version 20 — May 3, 2005
Page 46