Chapter 5
Troubleshooting
Identifying and Diagnosing Hardware Problems
89
Keyword: Type-02 1b0800 1771520
Hot Swap Cage: SCSI cable removed
Logged by: BMC;
Sensor: Cable / Interconnect - SCSI ChExt Cable
Data1: Device Removed/Device Absent
0x203E4D0AC6020220 FFFF0008F61B0300
Log Entry 73: 00:00:12
Alert Level 3: Warning
Keyword: Type-02 050301 328449
The server's built-in sensors have detected an open chassis door.
Logged by: BMC;
Sensor: Physical Security - Chassis Open
Data1: State Asserted
0x200000000C020570 FFFF010302050300
NOTE
More detailed information on the system logs is presented in Chapter 4, “Utilities.”
Systems without a Management Processor Card
The system LED states operate the same with systems having the optional management processor card.
Diagnostic LEDs
Four diagnostic LEDs are provided on the display panel of the system. Additional diagnostic LEDs are
provided on the system board and are described later in this chapter.
The diagnostic LEDs warn of impending failures or present failures and allow you to take preventive or
corrective action, such as making a system backup or replacing a component. These diagnostic LEDs are
labeled 1, 2, 3 and 4.
•
If no management processor card is installed, the boot progress is monitored by diagnostic LEDs 1
through 4. During the boot-up the LEDs will turn on in sequence until the EFI prompt is reached.
Table 5-3
Power and System LED States
Power LED
System LED
State
Off
Off
Off
On (green)
Solid green
Running
On (green)
Blinking green
Booting or running code other than
operating system (boot or
diagnostic).
On (green)
Blinking yellow (1/sec.)
Attention indication
On (green)
Blinking red (2/sec.)
Fault indication