HP Indigo press ws4000 Cluster 1 procedures
proprietary and confidential
CA293-00600, Rev 00
page 88 of 221
Installing the Unwinder Vacuum box
•1. Install in the Input side brackets on the Unwinder rear and front walls.
Figure 84 Input side vacuum box brackets
a. Install the new vacuum box Input side brackets in place, using the old
bracket spacers. Make sure that the round holes in the bracket are on
the bottom and the slots are on the top.
•2. Install the Output side vacuum box brackets on the vacuum box.
•3. From the Output side of the Unwinder, place the vacuum box in place in
the Unwinder.
•4. Reinstall the screws in the Input side of the brackets to secure the vacuum
box.
•5. Secure the Output side brackets to the Unwinder walls.
•6. Connect the vacuum hoses.