HP Indigo press ws4000 Cluster 1 procedures
proprietary and confidential
CA293-00600, Rev 00
page 78 of 221
Figure 74 Blower connector box connections
•21. Connect the wires to the blower connector boxes as they were before
Note:
Ensure that the wires from the inverter are not sharply bent as they fit in the
connector box.
a. Connect the wire labeled U to the right terminal.
b. Connect the wire labeled V to the middle terminal.
c. Connect the wire labeled W to the left terminal.
d. Connect the green and yellow wires to the ground terminal.
•22. Tie the orange blower wires in place in the cable track.
Connecting the inverter wires to the electric cabinet
The wires are color coded and their ends are labeled to indicate their destination.
•1. Separate the wires by color as they come from the bottom of the inverters.
•2. Tie them up and run them through the cable channel to the electric cabinet.
Note:
As you pass the wires through the channel, tie them down with tie wrap to keep
them neatly in the channel.
•3. The wires are labeled. Separate the wires by color and run them to their
positions in the cabinet: