Страница 1: ...Installation and Reference Guide HP J3136A HP AdvanceStack Switch 2000 Redundant Power Supply ...

Страница 2: ......

Страница 3: ...HP AdvanceStack Switch 2000 Redundant Power Supply Installation and Reference Guide ...

Страница 4: ...sequential damages in connection with the furnishing performance or use of this material Hewlett Packard assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett Packard Warranty A copy of the specific warranty terms applicable to your Hewlett Packard product and replacement parts can be obtained from your HP Sales and Service Office or aut...

Страница 5: ...ch 2000 Redundant Power Supply 2 At A Glance 2 Installation Summary 3 Included Parts 3 Installation Steps 4 Frequently Asked Questions 7 HP Customer Support Services 8 Specifications 11 Safety Information 13 Index 21 1 ...

Страница 6: ...to the Switch 2000 Features Network Connections Provides fully redundant power to the Switch 2000 Modular Easy to Use Design The RPS is easy to mount on the back of the Switch 2000 Each Switch 2000 has an RPS LED to report the status of the Redundant Power Supply RPS status information available from HP Stack Manager Windows 3 1 software shipped with the devices that support the RPS and HP Interco...

Страница 7: ...on Included Parts Each RPS has the following components shipped with it HP Switch 2000 Redundant Power Supply Installation and Reference Guide this manual J3136 90001 One AC power cord one of the following Australia New Zealand Denmark Europe Japan Switzerland United Kingdom U S Canada Mexico Taiwan 8120 1369 8120 2956 8120 1689 8120 4753 8120 2104 8120 1351 8120 1378 Installation Summary 3 ...

Страница 8: ...alling the RPS Electrical shock or other injury can result if you attempt to install the module without unplugging the Switch 2000 2 Using a Torx T 10 or flat bladed screw driver loosen the five cap tured screws on the cover plate on the back of the Switch 2000 3 Store the cover plate Steps continued on next page Loosen these screws Installation Summary 4 ...

Страница 9: ...and insert the tabs into the three slots on the Switch 2000 as shown below 6 Rotate the RPS up and towards the Switch 2000 Then push the RPS until it is firmly seated into the connector inside the Switch 2000 Metal tabs RPS attaching to Switch 2000 metal tabs first Rotate the RPS up Installation Summary 5 ...

Страница 10: ...roblems Diagnostic Tips Fault Power Fault RPS OFF OFF ON The RPS is connected and functioning properly Flashing Slowly Flashing Slowly OFF The RPS is present but failed Try Verify that the power cords are connected at both ends Verify the AC outlet is providing power to another device Try a different power cord If the problem persists the RPS power supply may have failed Contact your HP authorized...

Страница 11: ... provide power To order an HP UPS call 1 800 538 8787 An RPS Redundant Power Supply is an external power backup device The power supply of the RPS is duplicated redundant of the Switch 2000 so that if one power supply component fails the RPS will still provide power Should I keep my device s AC power cord connected Yes Otherwise you do not have redundant power Do I have to plug both AC power cords...

Страница 12: ...vice After you download the file s from one of these sources you type filename x HP BBS and World Wide Web The HP BBS phone number is 208 344 1691 Set your modem communication settings to parity N data bits 8 stop bits 1 baud rates 300 1200 2400 4800 9600 or 14400 The URL address for the World Wide Web is http www hp com go network_city From this web site you can download files and learn about HP ...

Страница 13: ... The ftp prompt appears 11 At the ftp prompt enter anonymous 12 At the password prompt enter your internet e mail address 13 At the ftp prompt set the file type to binary binary 14 Retrieve the file by entering get filename exe 15 Quit the FTP session by entering quit 16 Extract the file e g filename x HP Customer Support Services 9 ...

Страница 14: ... is available 24 hours a day seven days a week HP FIRST provides information on product informa tion troubleshooting technical reviews and configuration information To access HP FIRST dial one of the following phone numbers from your touch tone telephone Location Phone Number U S and Canada Only 1 800 333 1917 and press 1 for HP FIRST Outside the U S and Canada 1 208 344 4809 and press 9 for HP FI...

Страница 15: ...of 10 Maximum current 2 5 A 1 5 A Frequency range 50 60 Hz 50 60 Hz Environmental Operating Non Operating Temperature 0 C to 55 C 32 F to 131 F 40 C to 70 C 40 F to 158 F Relative humidity non condensing 15 to 95 at 40 C 104 F 90 at 65 C 149 F Maximum altitude 4 6 km 15 000 ft 4 6 km 15 000 ft Safety IEC 950 1991 A1 A2 EN60950 I 1992 A1 A2 UL1950 CSA 950 continued on next page Specifications 11 ...

Страница 16: ...A EN 55022 CISPR 22 Class A VCCI Level I Complies with Canadian EMC Class A requirements Immunity See the Declaration of Conformity in the HP AdvanceStack Switch 2000 Installation and Reference Guide Acoustic Noise 5 5 Bels max Specifications 12 ...

Страница 17: ...he product s input wiring terminals power cord or supplied power cord set Whenever it is likely that the protection has been impaired disconnect the power cord until the ground has been restored For LAN cable grounding If your LAN covers an area served by more than one power distribution system be sure their safety grounds are securely interconnected LAN cables may occasionally be subject to hazar...

Страница 18: ...on d alimentation ou le cordon de raccordement fourni avec le produit Lorsque cette protection semble avoir été endommagée débrancher le cordon d alimentation jusqu à ce que la mise à la terre ait été réparée Mise à la terre du câble de réseau local si votre réseau local s étend sur une zone desservie par plus d un système de distribution de puissance assurez vous que les prises de terre de sécuri...

Страница 19: ...eterminals den Netzkabeln oder dem mit Strom belieferten Netzkabelsatz voraus Sobald Grund zur Annahme besteht daß der Schutz beeinträchtigt worden ist das Netzkabel aus der Wandsteckdose herausziehen bis die Erdung wiederhergestellt ist Für LAN Kabelerdung Wenn Ihr LAN ein Gebiet umfaßt das von mehr als einem Stromverteilungssystem beliefert wird müssen Sie sich vergewissern daß die Sicherheitser...

Страница 20: ...azione oppure al set cavo d alimentazione fornito con il prodotto Ogniqualvolta vi sia probabilità di danneggiamento della protezione disinserite il cavo d alimentazione fino a quando il collegamento a terra non sia stato ripristinato Per la messa a terra dei cavi LAN se la vostra LAN copre un area servita da più di un sistema di distribuzione elettrica accertatevi che i collegamenti a terra di si...

Страница 21: ... aparato el cable de alimentación o el juego de cable de alimentación suministrado Si existe la probabilidad de que la protección a tierra haya sufrido desperfectos desenchufar el cable de alimentación hasta haberse subsanado el problema Puesta a tierra del cable de la red local LAN Si la LAN abarca un área cuyo suministro eléctrico proviene de más de una red de distribución de electricidad cercio...

Страница 22: ...Safety Information Japanese Safety Information 18 ...

Страница 23: ...s equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference If this equipment causes interference to radio reception which can be determined by unplug ging the power cord from the equipment try these measures Re orient the receiving antenna Relocate the equipment w...

Страница 24: ...ormity This product is designed for operation with the J3100A HP AdvanceStack Switch 2000 and is listed in the Declaration of Conformity included in the HP AdvanceStack Switch 2000 Installation Guide Safety Information 20 ...

Страница 25: ...ng to get HP product information 10 frequently asked questions 7 ftp obtaining files from HP 9 H Hourly support calling for 10 HP FIRST Fax Retrieval Service using 10 HP FTP Library Service using 9 I included parts 3 installation summary 3 6 Internet obtaining software from 8 9 N Network Phone In Support phone number for 10 P parts included with the RPS 3 physical specifications of hubs 11 power s...

Страница 26: ...T troubleshooting table 6 W World Wide Web obtaining software from 8 WWW obtaining software from 8 Index 22 ...

Страница 27: ......

Страница 28: ... Copyright 1996 Hewlett Packard Company Printed in U S A 3 96 Manual Part Number J3136 90001 Edition 1 J3136 90001 ...

Отзывы: