Specifications 96
Specifications
Environmental specifications
Specification
Value
Temperature range*
Operating
0
°
C to 40
°
C (32
°
F to 104
°
F)
Nonoperating
-30
°
C to 65
°
C (-22
°
F to 149
°
F)
Relative humidity
(noncondensing)
Operating, maximum wet bulb
temperature of 28°C (82.4°F)
10% to 90%
Nonoperating, maximum wet
bulb temperature of 38.7°C
(101.7°F)
0% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1° C per 304.8 m (1.8° F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
Server specifications
Specification
Tower model
Height
36.83 cm (14.50 in)
Depth
47.50 cm (18.70 in)
Width
17.50 cm (6.89 in)
Weight (full load, approximate values)
—
Four-bay LFF non-hot-plug model
13.1 kg (28.82 lb)
Four-bay LFF hot-plug drive model
13.6 kg (29.92 lb)
Eight-bay SFF hot-plug drive model
12.4 kg (27.28 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
HPE 350 W Power Supply (E-star 1.0)
•
HPE 350 W Power Supply (E-star 2.0)
•
HPE 460 W CS Gold Hot-plug Power Supply (92% efficiency)
This power input module is only supported when the two-bay RPS assembly option is installed.
CAUTION:
Check the system and power supply input ratings before powering up the server.
For detailed power supply specifications, see the QuickSpecs on the Hewlett Packard Enterprise website
(
http://www.hpe.com/info/proliant/powersupply
).