background image

HP InfiniBand

QLogic InfiniBand 4X QDR PCI-E G2 Dual Port HCA

583211-B21

HP InfiniBand 4X QDR ConnectX-2 PCIe G2 Dual Port HCA

592520-B21

HP InfiniBand FDR/EN 10/40Gb Dual Port 544QSFP Adapter

649281-B21

NOTE:

 Please see the QuickSpecs for additional information:

http://h18000.www1.hp.com/products/quickspecs/13078_na/13078_na.html

.

 

HP I/O Expansion Options

HP DL360 G6 PCI-X Riser Kit

NOTE:

 To convert full-length, full-height PCI-Express slot to PCI-X slot for PCI-X cards

only.

518824-B21

HP Power Supplies

NOTE:

 Prior to making a power supply selection it is highly recommended that the HP

Power Advisor is run to determine the right size power supply for your server
configuration. The HP Power Advisor is located at: 

www.hp.com/go/hppoweradvisor

.

HP 460W Common Slot Gold Hot Plug Power Supply Kit

NOTE:

 Standard on most models.

503296-B21

HP 460W Common Slot Platinum Hot Plug Power Supply Kit

593188-B21

HP 750W Common Slot Gold Hot Plug Power Supply Kit

512327-B21

HP 750W Common Slot Platinum Hot Plug Power Supply Kit

NOTE:

 Standard on Efficiency Model Server.

593831-B21

HP 1200W Common Slot Silver Hot Plug Power Supply Kit

500172-B21

HP 1200W Common Slot -48VDC Hot Plug Power Supply Kit

NOTE:

 DC power supplies contain a -48V DC power cord designed for in rack DC power

rectifiers.

437573-B21

NOTE:

 Option Kits contain optional power supply, an IEC power cable and PDU IEC

cables.

HP Graphic Options

NVIDIA Quadro 4000 2GB PCI-E Adapter

NOTE:

 HP Quadro 4000 PCIe Graphics Adapter requires HP PCI Thermal Power Kit

(519254-B21), as well as a choice of a higher power HP Common Slot Pwr Supply Kit.

NOTE:

 Please see the HP Power Advisor for estimated power consumption of your

individual system configuration prior to installing GPUs. The HP Power Advisor is
located at: 

www.hp.com/go/hppoweradvisor

.

655933-B21

HP DL360G6 PCI Thermal Power Cable Kit

NOTE: 

Supports 3rd Party PCI Video Graphics cards.

519254-B21

QuickSpecs

HP ProLiant DL360 Generation 7 (G7)

Core Options

DA - 13598   North America — Version 56 — March 25, 2013

Page  26

Содержание HP DL360 G7

Страница 1: ...rofile 2 Up to two Intel processors 2 PCI Express expansion slot 2 full height full length x16 16 8 4 2 1 75W EXT 75W option for PCI X card only support 3 Video connector 3 Power supply bay 1 populated 4 Slide out System Insight Display SID 4 Power supply bay 2 5 Removable fan modules for easy serviceability 5 iLO 3 NIC connector 6 Eighteen DIMM slots DDR3 Registered RDIMM or Unbuffered UDIMM memo...

Страница 2: ...L5630 2 13GHz 4 core 12MB 40W DDR3 1066 HT Turbo 1 1 2 2 Processor Intel Xeon E5606 2 13GHz 4 core 8MB 80W DDR3 800 Processor Intel Xeon E5603 1 60GHz 4 core 4MB 80W DDR3 800 Processor NOTE Up to 2 processors supported Performance Model configurations include two processors NOTE HT indicates that the processor model supports Intel Hyper Threading Technology NOTE Turbo indicates the maximum potenti...

Страница 3: ... 192GB 6 slots x 32GB 1066MHz Maximum Capacity UDIMM 48GB 12 slots x 4GB 1333MHz NOTE If only one processor is installed only half the DIMM slots are available NOTE When populating with two processors the 16GB or 32GB Memory Kits Quad Rank only 12 DIMMs can be populated NOTE Depending on the memory configuration and processor model the memory speed may run at 1333MHz 1066MHz or 800MHz Please see t...

Страница 4: ...Memory Controller RAID 0 1 1 0 Available Smart Array upgrades 256MB Battery kit upgrade to add BBWC to the 256MB Memory option 512MB BBWC 512MB FBWC or 1G FBWC and Smart Array Advanced Pack SAAP Internal Storage Devices Diskette Drive None Optical Drive One of the following depending on Model Optional DVD ROM DVD RW NOTE This option available on 4 drive bay models only Optional HP External USB CD ...

Страница 5: ... to offer multiple power solutions to fit the customers needs Many HP ProLiant Servers come with high efficiency CS Power Supplies HP s new CS power supplies are designed to provide power efficiency without degrading performance of the ProLiant Power Supplies will have efficiency ratings up to 94 There are multiple CS power output options available allowing you to right size the most appropriate p...

Страница 6: ...n Software and latest listing of software drivers available for your server including how to purchase from HP please visit our OS Support Site at http www hp com go ossupport Graphics Integrated ATI ES1000 32MB video standard 16 bit color maximum resolution of 1600 x 1200 32 bit color maximum resolution of 1280 x 1024 NOTE Maximum resolution available via iLO 3 remote console for ProLiant is 1280 ...

Страница 7: ...lity to set their own specific baseline The Service Pack for ProLiant has been rigorously tested with specific attention for interaction between firmware drivers and agents both within the server as well as in interaction with the BladeSystem enclosure components Onboard Administrator and Virtual Connect This testing ensures the highest quality as well as providing the input for HP SUM to deploy u...

Страница 8: ...Channel Partners resellers Hardware diagnostic support and repair is available for three years from date of purchase Support for software and initial setup is available for 90 days from date of purchase Enhancements to warranty services are available through HP Care Pack services or customized service agreements Hard drives have either a one year or three year warranty refer to the specific hard d...

Страница 9: ...ul toolkit integrated by design that accelerates complex technology projects and simplifies daily operations transforming data center economics With Insight Dynamics IT professionals can plan capacity and power continuously balance workloads across physical and virtual resources and ensure cost effective high availability It also enables IT organizations to provision infrastructure consistently an...

Страница 10: ...e software Our storage software helps you reduce costs simplify storage infrastructure protect vital assets and respond faster to business opportunities Storage software that gets the job done Data Protection and Recovery Software Whether you re a large enterprise or a smaller business HP data protection and recovery software will cost effectively protect you against disaster and ensure business c...

Страница 11: ... storage products Customers can choose how their factory solutions are built tested integrated shipped and deployed Factory Express offers service packages for simple configuration racking installation complex configuration and design services as well as individual factory services such as image loading asset tagging and custom packaging HP products supported through Factory Express include a wide...

Страница 12: ... devices and networking options to assist you in bringing your new hardware into operation in a timely and professional manner http h20195 www2 hp com V2 GetPDF aspx 5981 9356EN HP Installation and Startup for Insight Control Software Provides for the deployment and basic configuration of HP Insight Control on HP ProLiant ML and DL series servers or HP BladeSystem servers http h20195 www2 hp com v...

Страница 13: ...f HP branded servers storage devices and networking options to assist you in bringing your new hardware into operation in a timely and professional manner http h20195 www2 hp com V2 GetPDF aspx 5981 9356EN 3 Year HP 24x7 4 hour Response Hardware Support Onsite Service Provides for the deployment and basic configuration of HP Insight Control on HP ProLiant ML and DL series servers or HP BladeSystem...

Страница 14: ...Intel Xeon X5650 2 66GHz 6 core 12MB 95W DDR3 1333 HT Turbo 2 2 2 2 3 3 Processors Cache Memory 12MB 1 x 12MB Level 3 cache Memory 12 GB 6 x 2 GB PC3 10600R DDR3 1333 Registered DIMMs NOTE Total of 18 DDR3 DIMM slots Network Controller Two HP NC382i Dual Port Multifunction Gigabit Server Adapter 4 x 1Gb Ports Storage Controller HP Smart Array P410i 1GB FBWC Hard Drive None ship standard Internal S...

Страница 15: ...ck form factor 1 75 less than 28 inches 70 5 cm deep Warranty Server Warranty includes 3 Year Parts 3 Year Labor 3 Year Onsite support with next business day response Entry Models Quad Core Models HP ProLiant DL360 G7 E5606 1P 4GB R P410i ZM 4 SFF 460W RPS Server 633778 001 Processor s One of the following depending on Model 1 Intel Xeon E5606 2 13GHz 4 core 8MB 80W DDR3 800 Processor Cache Memory...

Страница 16: ...ion Gigabit Server Adapter 4 x 1Gb Ports Storage Controller HP Smart Array P410i Zero Memory Controller Hard Drive None ship standard Internal Storage 4 SFF SAS SATA HDD Bays with optional 4SFF HDD upgrade Optical Drive None ship standard PCI Express Slots PCIe 2 01 full length full height and 1 low profile Power Supply One 460W Common Slot Platinum Hot Plug Power Supply Fans 3 total fans redundan...

Страница 17: ...orts Storage Controller HP Smart Array P410i 512MB FBWC Memory Controller Hard Drive None ship standard Internal Storage 4 SFF SAS SATA HDD Bays Optical Drive HP DL360 SL 12 7mm SATA DVD RW Power Supply 2 460W Hot Plug Power Supply Fans 3 fan redundancy standard Form Factor 1U Rack form factor 1 75 less than 28 inches 70 5 cm deep HP DL360 G7 E5649 US Svr S Buy 640011 005 Processor s 2 Intel Xeon ...

Страница 18: ...ches 70 5 cm deep Management Insight Control HP DL360 G7 X5675 US Svr S Buy 640013 005 Processor s 2 Intel Xeon X5675 3 06GHz 6 core 12MB 95W Memory 8GB 2x 4GB PC3 10600R DDR3 1333 Registered DIMMs Network Controller Two HP NC382i Dual Port Multifunction Gigabit Server Adapter 4 x 1Gb Ports Storage Controller HP Smart Array P410i 512MB FBWC Memory Controller Hard Drive None ship standard Internal ...

Страница 19: ... Choose Required Options only one of the following from each list unless otherwise noted HP Processors Six Core Processors HP DL360 G7 Intel Xeon X5690 3 46GHz 6 core 12MB 130W FIO 2 processor Kit NOTE This kit includes two processors 644131 L21 HP DL360 G7 Intel Xeon X5675 3 06GHz 6 core 12MB 95W FIO Processor Kit 633781 L21 HP DL360 G7 Intel Xeon X5670 2 93GHz 6 core 12MB 95W FIO Processor Kit 5...

Страница 20: ... 1x16GB Dual Rank x4 PC3L 10600 DDR3 1333 Registered CAS 9 LP Memory Kit 627812 B21 HP 32GB 1x32GB Quad Rank x4 PC3L 8500 DDR3 1066 Registered CAS 7 LP Memory Kit 627814 B21 Unbuffered with ECC DIMMs UDIMMs HP 1GB 1x1GB Single Rank x8 PC3 10600 DDR3 1333 Unbuffered CAS 9 Memory Kit 500668 B21 HP 2GB 1x2GB Dual Rank x8 PC3 10600 DDR3 1333 Unbuffered CAS 9 Memory Kit 500670 B21 HP 4GB 1x4GB Dual Ran...

Страница 21: ...1 B21 HP Smart Array P411 256 BBWC 2 ports Ext PCIe x8 FIO SAS Controller 491193 B21 NOTE For more information on optional controllers http h18004 www1 hp com products servers proliantstorage arraycontrollers index html HP Performance Packs The HP ProLiant DL360 G7 performance packs are necessary to configure a HP ProLiant DL360 G7 Performance Model HP ProLiant DL360 G7 Performance model includes ...

Страница 22: ...GHz 6 core 12MB 80W Processor Kit 633787 B21 HP DL360 G7 Intel Xeon L5640 2 26GHz 6 core 12MB 60W Processor Kit 588078 B21 Quad Core Processors HP DL360 G7 Intel Xeon X5672 3 20GHz 4 core 12MB 95W Processor Kit 633783 B21 HP DL360 G7 Intel Xeon E5640 2 66GHz 4 core 12MB 80W Processor Kit 588068 B21 HP DL360 G7 Intel Xeon E5630 2 53GHz 4 core 12MB 80W Processor Kit 588070 B21 HP DL360 G7 Intel Xeon...

Страница 23: ...emory Kit 500666 B21 HP S Buy 16GB 1x16GB Quad Rank x4 PC3 8500 DDR3 1066 Registered CAS 7 Memory Kit 500666 S21 500666 S21 HP 16GB 1x16GB Dual Rank x4 PC3L 10600 DDR3 1333 Registered CAS 9 LP Memory Kit 627812 B21 HP 32GB 1x32GB Quad Rank x4 PC3L 8500 DDR3 1066 Registered CAS 7 LP Memory Kit 627814 B21 Unbuffered with ECC DIMMs UDIMMs HP 1GB 1x1GB Single Rank x8 PC3 10600 DDR3 1333 Unbuffered CAS...

Страница 24: ...r Warranty Hard Drive 581284 B21 HP 300GB 6G SAS 15K rpm SFF 2 5 inch Hot Plug Enterprise 3 yr Warranty Hard Drive 627117 B21 HP 300GB 6G SAS 10K rpm SFF 2 5 inch Dual Port Enterprise 3yr Warranty Hard Drive 507127 B21 HP 146GB 6G SAS 15K rpm SFF 2 5 inch Dual Port Enterprise 3yr Warranty Hard Drive 512547 B21 SAS Hot Plug SFF 2 5 inch Midline MDL Drives HP 1TB 6G SAS 7 2K rpm SFF 2 5 inch Dual Po...

Страница 25: ... NC112T PCI Express Gigabit Server Adapter 503746 B21 HP NC360T PCI E Dual Port Gigabit Server Adapter 412648 B21 HP NC365T 4 port Ethernet Server Adapter 593722 B21 HP NC373F PCI E Multifunction 1000SX Gigabit Svr Adapter 394793 B21 HP NC373T PCI E Multifunction Gigabit Server Adapter 394791 B21 HP NC375T PCI Express Quad Port Gigabit Server Adapter 538696 B21 HP NC382T PCI Express Dual Port Mult...

Страница 26: ...750W Common Slot Gold Hot Plug Power Supply Kit 512327 B21 HP 750W Common Slot Platinum Hot Plug Power Supply Kit NOTE Standard on Efficiency Model Server 593831 B21 HP 1200W Common Slot Silver Hot Plug Power Supply Kit 500172 B21 HP 1200W Common Slot 48VDC Hot Plug Power Supply Kit NOTE DC power supplies contain a 48V DC power cord designed for in rack DC power rectifiers 437573 B21 NOTE Option K...

Страница 27: ...nt certificate The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key s Includes one year of 24 x 7 HP Software Technical Support and Update Service NOTE Licenses ship without media The HP Insight Control Media Kit can be ordered separately or can be downloaded at http www hp com go insightupdates NOTE For additional license options ple...

Страница 28: ...r multiple licenses with a single activation key Each license is for one socket a k a processor Customer will receive a printed end user license agreement and license entitlement certificate via physical shipment The license entitlement certificate must be redeemed online in order to obtain a license key TC293B HP High Performance Computing Linux Value Pack Media Kit for ProLiant Servers NOTE This...

Страница 29: ...AS Controllers Smart Array P212 Controller HP Smart Array P212 ZM 1 ports Int 1 ports Ext PCIe x8 SAS Controller 462828 B21 HP Smart Array P212 256 1 ports Int 1 ports Ext PCIe x8 SAS Controller 462834 B21 Smart Array P411 Controller HP Smart Array P411 256 2 ports Ext PCIe x8 SAS Controller 462830 B21 HP Smart Array P411 512 BBWC 2 ports Ext PCIe x8 SAS Controller 462832 B21 HP Smart Array P411 5...

Страница 30: ...t Array P212 Controller http h18000 www1 hp com products quickspecs 13202_na 13202_na html Smart Array P411 Controller http h18000 www1 hp com products quickspecs 13558_na 13558_na html Smart Array P812 Controller http h18000 www1 hp com products quickspecs 13200_na 13200_na html Smart Array Advanced Pack SAS HBA HP Modular Smart Array SC08e 2 ports Ext PCIe x8 SAS Host Bus Adapter NOTE This is a ...

Страница 31: ...DW086B HP StoreEver LTO 2 Ultrium 448 SAS Internal Tape Drive DW085B HP StoreEver LTO 4 Ultrium 1760 SAS 1 in 1U Rack mount Kit EH946C HP StoreEver LTO 5 Ultrium 3000 SAS Tape Drive in 1U Rack mount EJ014B HP StoreEver LTO 6 Ultrium 6250 Tape Drive in 1U Rack mount Kit C0L99A HP StoreEver LTO 6 Ultrium 6650 Internal Tape Drive EH963A HP StoreEver LTO 6 Ultrium 6650 External Tape Drive EH964A HP St...

Страница 32: ...el Host Bus Adapter A8003B HP SN1000E 16Gb 2 port PCIe Fibre Channel Host Bus Adapter QR559A HP SN1000E 16Gb 1 port PCIe Fibre Channel Host Bus Adapter QR558A QLogic Fibre Channel HBAs HP 81Q 8Gb 1 port PCIe Fibre Channel Host Bus Adapter AK344A HP 82Q 8Gb 2 port PCIe Fibre Channel Host Bus Adapter AJ764A HP FC1142SR 4Gb 1 port PCIe Fibre Channel Host Bus Adapter AE311A HP FC1242SR 4Gb 2 port PCIe...

Страница 33: ...lease go to www hp com servers rackups NOTE For additional information on sizing your server please reference http www upssizer com NOTE Please see the UPS and PDU cable matrix s on the HP Power Protection and Management page Under Power Cords click on the HP Power Cord Matrix link That link will list cable descriptions requirements and specifications for UPS and PDU units Please see the following...

Страница 34: ...e Phase IEC309 NA Core Intelligent Power Distribution Unit AF901A HP 17 3kVA 48A 208V Three Phase 12 Outlet Core NA JP Intelligent Power Distribution Unit AF535A HP 17 3kVA 24A 415V Three Phase 12 Outlet Core NA JP Intelligent Power Distribution Unit AF537A PDU Extention Bars HP 5xC13 Intelligent PDU Extension Bar G2 Kit AF547A HP 5xC13 Outlets Power and UID LEDs Pair Standard Extension Bar AF528A...

Страница 35: ...ndard Keyboard DT528A ABA HP 4GB SD Enterprise Performance Flash Media Kit NOTE Blank SD media device is supported for use with VMware and Citrix SD media must be installed in the internal slot of the ProLiant server Learn more at http www hp com go proliantvirtualization 580387 B21 HP Care Pack Services Proactive Care NOTE Collaborative Support plus Proactive services delivered by the onshore loc...

Страница 36: ...e Personalized Support Option NOTE To add an onsite Account Support Manager ASM to Proactive Care ASM is an assigned resource who delivers support planning and brings technical expertise and best practices advices for the customer s environment HP 3yr Provides annual personalized proactive supp for existing Proactive Care ISS centric environment U6W98E Installation Services NOTE Reduce the time re...

Страница 37: ...nk DIMM 1 dual rank DIMM or 1 quad rank DIMM 1 single rank DIMM You can only install two quad rank DIMMs per channel You can only install two UDIMMs per channel if available the third slot in the channel must remain empty Populate DIMMs from heaviest load quad rank to lightest load single rank within a channel Heaviest load DIMM with most ranks within a channel goes furthest from the chipset For m...

Страница 38: ...nnel 2 you still run at 1066MHz If you install 1x 1066MHz DIMM in channel 1 and 5x 1333MHz DIMMs with 1 DIMM Per Channel DPC in each of the other channels you run at 1066MHz If you install 3DPC in one channel if applicable and 1DPC in all other channels you run at 800MHz References to the above MHz speeds are for the various speeds of DDR3 DIMMs 1333 refers to DDR3 1333 etc DIMM slot and configura...

Страница 39: ...rank PC3 10600 RDIMMs 6x 8GB dual rank PC3 8500 RDIMMs CPU1 CPU2 slot population order slot population order Chnl 1 1 G 8GB DIMM 1 G empty Chnl 1 2 D 8GB DIMM 2 D empty 3 A 2GB DIMM 3 A empty Chnl 2 4 H 8GB DIMM 4 H empty Chnl 2 5 E 8GB DIMM 5 E empty 6 B 2GB DIMM 6 B empty Chnl 3 7 I 8GB DIMM 7 I empty Chnl 3 8 F 8GB DIMM 8 F empty 9 C 2GB DIMM 9 C empty Standard memory replaced with optional mem...

Страница 40: ... 10600 UDIMMs CPU1 CPU2 slot population order slot population order Chnl 1 1 G empty 1 G empty Chnl 1 2 D 2GB DIMM 2 D empty 3 A 2GB DIMM 3 A empty Chnl 2 4 H empty 4 H empty Chnl 2 5 E 2GB DIMM 5 E empty 6 B 2GB DIMM 6 B empty Chnl 3 7 I empty 7 I empty Chnl 3 8 F 2GB DIMM 8 F empty 9 C 2GB DIMM 9 C empty Standard memory replaced with optional memory 2 CPU model RDIMM maximum configuration 384GB ...

Страница 41: ...3 10600 UDIMMs CPU1 CPU2 slot population order slot population order Chnl 1 1 G empty 1 G empty Chnl 1 2 D 2GB DIMM 2 D 2GB DIMM 3 A 2GB DIMM 3 A 2GB DIMM Chnl 2 4 H empty 4 H empty Chnl 2 5 E 2GB DIMM 5 E 2GB DIMM 6 B 2GB DIMM 6 B 2GB DIMM Chnl 3 7 I empty 7 I empty Chnl 3 8 F 2GB DIMM 8 F 2GB DIMM 9 C 2GB DIMM 9 C 2GB DIMM NOTE Capacity references are rounded to the common Gigabyte values 1GB 10...

Страница 42: ... LP Memory Kit 627812 B21 HP 32GB 1x32GB Quad Rank x4 PC3L 8500 DDR3 1066 Registered CAS 7 LP Memory Kit 627814 B21 NOTE Low Voltage DIMMs can only be used with Intel Xeon processor 5600 series processors Unbuffered with ECC DIMMs UDIMMs HP 1GB 1x1GB Single Rank x8 PC3 10600 DDR3 1333 Unbuffered CAS 9 Memory Kit 500668 B21 HP 2GB 1x2GB Dual Rank x8 PC3 10600 DDR3 1333 Unbuffered CAS 9 Memory Kit 5...

Страница 43: ...NOTE PC3L is a low voltage memory QuickSpecs HP ProLiant DL360 Generation 7 G7 Memory DA 13598 North America Version 56 March 25 2013 Page 43 ...

Страница 44: ... the HBA controller firmware and the server backplane should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components NOTE Hard drives have either a one year or three year warranty refer to the specific hard drive QuickSpecs for details SAS Hot Plug SFF 2 5 inch Enterprise ENT Drives Quantity Supported Position Supported Contr...

Страница 45: ...D 200GB 3 0G SATA SSD 100GB 3 0G SATA SSD 8 1 8 HP Smart Array P212 Zero Memory Controller HP Smart Array P212 256 MB Controller HP Smart Array P411 256 MB Controller HP Smart Array P411 512 MB BBWC Controller 6G SAS Hot Plug Enterprise Performance Solid State Drives Quantity Supported Position Supported Controller 400GB 6G SAS SLC SFF 200GB 6G SAS SLC SFF 8 1 8 HP Smart Array P212 Zero Memory Con...

Страница 46: ...Smart Array P411 1G Flash Backed Write Cache HP Smart Array P812 1G Flash Backed Cache Controller Tape and Disk Backup NOTE For the complete range of tape drives autoloaders libraries and media including the internal fitting models see http www hp com go tape For the complete range of D2D Backup Systems see http www hp com go d2d For the complete range of RDX drives and media see http www hp com g...

Страница 47: ...MSL8096 MSL6000 External HP U320e SCSI Dual Channel Host Bus Adapter AH627A NOTE Please check the full compatibility information at http www hp com storage SPOCK HP SAS Tape Autoloaders and Libraries 1 8 G2 Autoloader MSL2024 MSL4048 MSL8096 External HP Smart Array P212 ZM 1 ports Int 1 ports Ext PCIe x8 SAS Controller 462828 B21 NOTE Please check the full compatibility information at http www hp ...

Страница 48: ...ator the QLogic QLA4050 Host Bus Adapter is recommended HP D2D Backup Systems Fibre Channel D2D4000fc External Direct server attach is not supported requires connection via SAN fabric See http www hp com storage SPOCK N A QuickSpecs HP ProLiant DL360 Generation 7 G7 Storage DA 13598 North America Version 56 March 25 2013 Page 48 ...

Страница 49: ... 1794 1773 1725 1725 1715 1715 1715 HP 460W Common Slot Platinum Hot Plug Power Supply Kit Part Number 593188 B21 Input Voltage Range V rms 100 to 240 Frequency Range Nominal Hz 50 60 Nominal Input Voltage Vrms 100 120 200 208 220 230 240 Maximum Rated Output Wattage Rating 460 460 460 460 460 460 460 Nominal Input Current A rms 5 3 4 3 2 5 2 4 2 3 2 2 2 1 Maximum Rated Input Wattage Rating Watts ...

Страница 50: ...2925 2892 2812 2812 2797 2797 2797 HP 750W Common Slot Platinum Hot Plug Power Supply Kit Part Number 593831 B21 Input Voltage Range V rms 100 to 240 Frequency Range Nominal Hz 50 60 Nominal Input Voltage Vrms 100 120 200 208 220 230 240 Maximum Rated Output Wattage Rating 750 750 750 750 750 750 750 Nominal Input Current A rms 8 6 7 1 4 2 4 0 3 8 3 6 3 4 Maximum Rated Input Wattage Rating Watts 8...

Страница 51: ...600 4600 4600 4600 4600 HP 1200W Common Slot Silver Hot Plug Power Supply Kit Part Number 437573 B21 Input Voltage Range V rms 36 72 Frequency Range Nominal Hz DC Nominal Input Voltage Vrms 36 48 72 Maximum Rated Output Wattage Rating 1200 1200 1200 Nominal Input Current A rms 38 28 19 Maximum Rated Input Wattage Rating Watts 1380 1350 1365 Maximum Rated VA Volt Amp 1380 1350 1365 Efficiency 87 89...

Страница 52: ...ower supply Rated Steady State Power 460 W at 100 VAC 460 W at 200 VAC Maximum Peak Power 460 W at 100 VAC 460 W at 200 VAC NOTE See Power Supply Specifications tables for complete details on 460W PSU and optional 750W and 1200W Power Supply Options System Inlet Temperature Operating 10 to 35 C 50 to 95 F at sea level with an altitude derating of 1 0 C per every 305 m 1 8 F per every 1000 ft above...

Страница 53: ...e 72GB SAS HDD four 250GB 5400 rpm SATA hard drives six system fans three 4GB 2x2GB DIMM s and one power supply 1P SKU Note 2 Configuration tested included two Intel X5520 quad core 2 27GHz processors one 72GB SAS HDD four 250GB 5400 rpm SATA hard drives eight system fans six 4GB 2x2GB DIMM s and one power supply 2P SKU Note 3 Values are subject to change without notification and are for reference...

Страница 54: ... 10 32bit and 64bit VMware ESX 4 0 VMware ESX 3 5 0 Client System Support Microsoft Windows 7 Microsoft Windows XP Professional Edition Microsoft Windows Vista Business and Ultimate Editions Red Hat Enterprise Desktop 5 00 SUSE Linux Enterprise Desktop 11 SUSE Linux Enterprise Desktop 10 Client Browser Support Microsoft Internet Explorer 8 Microsoft Internet Explorer 7 Microsoft Internet Explorer ...

Страница 55: ...2MB BBWC or 72 bit 512MB and 1G FBWC Logical Drives Supported Zero Memory Up to 2 logical volumes 8 physical drives Up to 64 logical drives with cache Host Memory Addressing 64 bit supporting greater than 4GB server memory space RAID Support RAID 6 6 0 Advanced Data Guarding NOTE RAID 6 6 0 can be enabled with one of the following combinations 256 MB cache Battery kit and Smart Array Advanced Pack...

Страница 56: ...d Approach End of life Management and Recycling Hewlett Packard offers end of life HP product return trade in and recycling programs in many geographic areas For trade in information please go to http www hp com go green To recycle your product please go to http www hp com go green or contact your nearest HP sales office Products returned to HP will be recycled recovered or disposed of in a respon...

Страница 57: ...stered trademark of Intel Corporation The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein For hard drives 1GB 1 billion bytes Actual formatted capacity i...

Отзывы: