Appendix D Cooling system
CAUTION:
The chassis and power supplies use separate air aisles. Make sure the two aisles are not blocked
when the switch is operating.
To dissipate heat timely and ensure system stability, the switch uses the front-rear air aisle cooling
system. Consider the site ventilation design when you plan the installation site for the switch.
Table 39 Cooling system for the switch
Switch model
Available fan trays
Airflow direction
•
HPE 5950
32QSFP28
•
HPE 5950
48SFP28
8QSFP28
X712 Bck(pwr)-Frt(prt) HV2
From the power supply side to the port side
X711 Frt(prt)-Bck(pwr) HV2
From the port side to the power supply side
HPE 5950 4-slot
Switch
5930 4-slot B(pwr) F(prt) Fan Tray
From the power supply side to the port side
5930 4-slot F(prt) B(pwr) Fan Tray
From the port side to the power supply side
Figure 63 Airflow from the power supply side to the port side through the HPE 5950
32QSFP28 chassis (with X712 Bck(pwr)-Frt(prt) HV2 fan tray)
Figure 64 Airflow from the port side to the power supply side through the HPE 5950
32QSFP28 chassis (with X711 Frt(prt)-Bck(pwr) HV2 fan trays)