68
Fabric OS Troubleshooting and Diagnostics Guide
53-1002150-02
Fabric identification issues
7
•
VE_Ports cannot exist in a logical switch that has XISL use turned on. Although VE_Ports are
allowed in a base switch, Fabric OS v6.2.0 and later do not support the use of VE_Ports to
carry traffic for logical fabrics using XISLs. They can be used to carry FCR traffic through EX_
and VEX_Ports. You should make sure your configuration does not result in the use of VE_Ports
in a base switch for logical fabric traffic.
•
Admin Domains are mutually exclusive with Virtual Fabrics. When Virtual Fabrics is enabled, all
access control is based on the Virtual Fabric context.
•
Traffic Isolation zones with no-failover option are not supported in logical fabrics. TI zones
defined in the base fabric for logical fabric traffic must allow failover.
NOTE
A new option “Disable FID check” has been added to configure fabric parameter options. This can
be used to disable FID check for FICON logical switches.
Fabric identification issues
Symptom
E_Ports directly connecting two logical switches do not form, or are disabled.
Probable cause and recommended action
The FIDs on each of the logical switches must be the same.
Use the lsCfg
--
show command to view the current FIDs on the chassis and then the lsCfg
--
change
FID
-newfid
FID
command
to change the FID.
Symptom
Invalid FID.
Probable cause and recommended action
FIDs for switches may be from 1 through 128 as long as they are not already in use, except
EX_Ports which are only assigned FIDs from 1 through 127.
Use the lsCfg
--
show command to verify if the FID is in use. If it is, use another FID.
Symptom
The FID is currently in use.
Probable cause and recommended action
You may not create two (2) or more logical switches with the same FID.
Use the lsCfg
--
show and fcrFabricShow commands to view FIDs in use.
Logical Fabric issues
Symptom
Logical port <port_number> disabled.
Probable cause and recommended action
This message indicates an LISL was disabled due to some protocol conflict or security or policy
violation. This can result in possible traffic issues. You should resolve the cause of the conflict and
re-enable the LISL using the lfCfg
--
lislenable command.
Содержание Fabric OS 7.0.0
Страница 4: ...iv Fabric OS Troubleshooting and Diagnostics Guide 53 1002150 02 ...
Страница 10: ...x Fabric OS Troubleshooting and Diagnostics Guide 53 1002150 02 ...
Страница 12: ...xii Converged Enhanced Ethernet Administrator s Guide 53 1002163 01 ...
Страница 14: ...xiv Converged Enhanced Ethernet Administrator s Guide 53 1002163 01 ...
Страница 64: ...44 Fabric OS Troubleshooting and Diagnostics Guide 53 1002150 02 Port mirroring 3 ...
Страница 70: ...50 Fabric OS Troubleshooting and Diagnostics Guide 53 1002150 02 Brocade configuration form 4 ...
Страница 86: ...66 Fabric OS Troubleshooting and Diagnostics Guide 53 1002150 02 FIPS 6 ...
Страница 132: ...112 Fabric OS Troubleshooting and Diagnostics Guide 53 1002150 02 Hexadecimal overview B ...
Страница 138: ...118 Fabric OS Troubleshooting and Diagnostics Guide 53 1002150 02 ...