HP E1663A Скачать руководство пользователя страница 35

Specifications

Mechanical Specifications

4-6

 Mechanical Specifications

Physical

Environmental Operating Conditions

Size

One C-size slot

Weight

1.6 kg (nominal)

Operating
Temperature

0 to 55

°

C.

Storage Temperature

40 to 75

°

C.

Humidity

50% to 95% relative humidity from 25 to 40

°

C.

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание E1663A

Страница 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Страница 2: ...e User s Guide SERIAL NUMBERS This manual applies directly to instruments with serial numbers prefixed 3114U For additional important information about serial numbers see Chapter 1 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 3: ...hanges To ensure that you receive these updates or new editions see your Hewlett Packard sales representative for details Notice Warranty Printing history Hewlett Packard Company 1994 All rights reserved Copyright Hewlett Packard Company IDACOM Telecommunications Operation 11120 178 Street Edmonton Alberta Canada T5S 1P2 We want to hear from you If you have any comments questions or suggestions ab...

Страница 4: ...Shipment 1 10 Packaging Requirements 1 10 2 Getting Started Overview 2 2 Connecting to an Optical Line Interface 2 4 Connecting to the System Under Test 2 5 Starting a Test Session 2 6 Log in to the HP Broadband Series Test System 2 6 3 C Function Reference Electrical Interface Library 3 3 Library Initialization 3 3 Amplifier Gain Setup 3 3 4 Specifications Electrical Specifications 4 3 Mechanical...

Страница 5: ...iv Contents Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 6: ...guration 1 6 Figure 2 1 Module address settings 2 4 Figure 2 2 Interconnecting the modules 2 6 Figure 2 3 Connecting to the system under test 2 7 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 7: ...x Figures Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 8: ...1 Introduction Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 9: ...escription of the Electrical Interface including identification and accessories the Control panel the front panel indicators and connectors the functional features safety considerations ESD precautions service storage and shipment Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 10: ...transmitted in the binary CMI Coded Mark Inversion format at 155 52 Mb s or 52 Mb s The data stream received from the System Under Test is CMI at 155 52 Mb s or 52 Mb s The clock is recovered from the incoming data and automatic compensation for cable loss and signal loss is provided Module Identification An identification label is attached to the Electrical Interface clamshell enclosure The seria...

Страница 11: ...dio button is selected the received signal is not amplified Manage Configuration files with these menus See Getting Started in your HP E1697A 155 Mb s Optical Line Interface User s Guide View the application and firmware versions and module identification details Set signal amplification See below Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 12: ... 5 V The con nector has open and short circuit protection and will withstand a maximum input of 5 V INTERMODULE CONNECTORS TRANSMIT CLOCK IN This SMA connector accepts the clock input from the HP E1697A It is an ECL input and is terminated in 50 Ω to 2 V dc nominal TRANSMIT DATA IN This SMA connector accepts data in the binary NRZ format from the HP E1697A It is an ECL input and is terminated in 5...

Страница 13: ...m Under Test page 2 5 for further details Figure 1 1 Typical Configuration See the HP E1697A 155 Mb s Optical Line Interface User s Guide HP p n E1697 90002 for guidance when configuring the 155 Mb s Optical Line Interface Transmitter The HP E1697A supplies binary NRZ nonreturn to zero formatted data signals and associated clock signals to the input of the Electrical Interface The Electrical Inter...

Страница 14: ...gnal can be switched through the monitor amplifier as required Equalization The equalization circuitry automatically compensates for signal degradation caused by cable loss in the network and applies the ƒ law for cables Clock Recovery and Decoding The receiver clock is recovered from the data stream for the subsequent decoding circuitry Decoding produces data signals in binary NRZ format and both...

Страница 15: ...ckard recommends that you use a controlled static workstation Handle the module by its front panel Avoid touching any components or edge connectors When you are ready to configure the module remove it from its protective bag and lay it on top of the bag while keeping your free hand in contact with the bag While configuring the module keep one hand in contact with the bag This technique maintains y...

Страница 16: ...you to obtain a fully tested and guaranteed restored exchange module at a reduced price The reduced price is contingent upon return of the defective module to Hewlett Packard The procedure for replacing a faulty Electrical Interface using the assembly exchange program is as follows 1 Order the replacement module HP p n E1663 69101 through your nearest HP Sales and Service Office Do NOT return the ...

Страница 17: ... test strength The carton must be large enough to allow 5 to 8 cm 2 to 3 in on all sides of the module for packing material and strong enough to accommodate the weight of the module 3 Surround the module with 5 to 8 cm 2 to 3 in of packing material to protect the module and prevent it from moving in the carton NEVER use styrene pellets as packaging material They do not adequately cushion the modul...

Страница 18: ...on adhesive tape 5 Mark the carton FRAGILE HANDLE WITH CARE 6 Retain copies of all shipping papers 7 In any correspondence refer to the module by model number and full serial number Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 19: ...Introduction Storage and Shipment 1 12 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 20: ...2 Getting Started Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 21: ...ons Once you have correctly installed the module software and online help Connect to the system under test 2 SONET SDH Electrical Interface User s Guide Start a test session Select protocols and modules If you are testing higher layers select them now 3 System Installation and Startup Guide Start the application 4 Connect to an optical line interface 1 SONET SDH Electrical Interface User s Guide A...

Страница 22: ...ptical Line Interface and the Electrical Interface for the test session 5 SONET SDH Electrical Interface User s Guide 155 Mb s Optical Line Interface or 52 Mb s Optical Line Interface User s Guide 155 Mb s Optical Line Interface or 52 Mb s Optical Line Interface User s Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 23: ...dule using RF cables with an SMA connector on one end and an SMB connector on the other Connections are shown in Figure 2 1 Figure 2 1 Interconnecting the modules HP E1663A SONET SDH Electrical Interface HP E1697A Optical Line Interface or HP E1617A Optical Line Interface Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 24: ... Connect the Electrical Interface to the System Under Test as shown Figure 2 2 Connecting to the system under test System Under Test HP E1663A SONET SDH Electrical Interface Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 25: ...oadband Series Test System Refer to Setting Up a Test Session and Starting a Test Session in the 155 Mb s Optical Line Interface User s Guide before logging into the HP Broadband Series Test System Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 26: ...3 C Function Reference Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 27: ... HP E1697A 155 Mb s Optical Line Interface module This chapter describes the Electrical Interface library See your 155 Mb s Optical Line Interface User s Guide for information on how to write test programs using the HP Broadband Series libraries Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 28: ...e functions returns 1 if an error occurs 0 otherwise Library Initialization int HptEif155InitLib Initializes the Electrical Interface library Amplifier Gain Setup int HptEif155SetInputGain int device int gain Sets the amplification of the input signal Gain parameters HPT_EIF155_GAIN_0DB no amplification HPT_EIF155_GAIN_20DB set up 20dB amplification Artisan Technology Group Quality Instrumentation...

Страница 29: ...C Function Reference Electrical Interface Library 3 4 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 30: ...4 Specifications Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 31: ...ions Parameters described as typical or nominal are supple mental characteristics which provide a useful indication of typical but non warranted performance All specifications are for 0 C to 55 C after a 30 minute warm up Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 32: ...ics dc Volts dc Current Dynamic Current Power Dissipation 5 V 1 1 A 110 mA 27 Watts 5 2 V 2 1 A 210 mA 2 V 1 3 A 130 mA 12 V 0 35 A 35 mA 12 V 0 32 A 32 mA Device Type Register based Backplane Connectors P1 P2 Module Keying ECL Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 33: ...gnal Level 0 5 Vpk 10 Return Loss 15 dB 7 MHz to 234 MHz Impedance Unbalanced 75 Ω to ground nominal Protection Open short circuit protected Connector BNC Clock 155 52 MHz with 50 10 duty cycle typical Data Serial stream 155 52 Mb s 20 ppm serial Format Non return to zero NRZ Timing Data set up time 3 9 ns Data hold time 1 1 ns Impedance 50 Ω nominal terminated to 2 V Level ECL Interface DC couple...

Страница 34: ... cater for nominal monitor point loss Return Loss 15 dB 7 MHz to 234 MHz Impedance Unbalanced 75 Ω to ground nominal Protection Maximum applied voltage 5 V short term Connector BNC Clock 155 52 MHz with 50 10 duty cycle typical Format Non return to zero NRZ Timing Data set up time 600 ps Data hold time 3 12 ns Impedance 50 Ω nominal terminated to 2 V Level ECL Interface DC coupled Connector SMA Ar...

Страница 35: ...nvironmental Operating Conditions Size One C size slot Weight 1 6 kg nominal Operating Temperature 0 to 55 C Storage Temperature 40 to 75 C Humidity 50 to 95 relative humidity from 25 to 40 C Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 36: ...PR11 EN55011 Electrical Safety Standards IEC 348 1978 CSA C22 2 No 231 Series M89 Communications Standards ANSI T1 105 1991 TR TSY 000253 ITU CCITT Recommendations G 703 Bellcore TA NWT 000253 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 37: ...Specifications Standards 4 8 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 38: ...ule 1 4 input amplification 1 7 interconnections 2 4 intermodule connectors 1 5 L label ESD 1 8 identification 1 3 LEDs front panel 1 5 line connectors 1 5 M module cabling 2 4 connections 2 4 identification label 1 3 module identification 1 4 monitor amplifier 1 7 P packaging 1 10 R receiver clock 1 7 receiver function 1 7 S service procedures 1 9 shipping details 1 9 1 10 signal amplification 1 ...

Страница 39: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Отзывы: