![HP dx6120 - Microtower PC Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/hp/dx6120-microtower-pc/dx6120-microtower-pc_quickspecs_165017019.webp)
*NOTE:
Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained
sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.
Power Supply
Slim Tower
Microtower
Power Supply
240 Watt Power Supply – active PFC
300 Watt Power Supply – passive PFC
(115v/230v line switch)
Maximum Rated Power
240 Watt
300 Watt
Full Ranging Input (No Line Select
Switch)
--
--
Active Power Factor Correction
(APFC) (Input Current is nearly
1/2 a non-APFC PS)
X
--
Passive Power Factor Correction
(PFC)
--
X
Operating Voltage Range
90 – 264 VAC
90 – 132/180 – 264 VAC
Rated Voltage Range
100 – 240 VAC
100 – 127/200 – 240 VAC
Rated Line Frequency
50/60 Hz
50/60 Hz
Operating Line Frequency Range
47 – 63 Hz
47 – 63 Hz
Rated Input Current
5A/2.5A
6A/3A
Heat Dissipation
Typical 341 btu/hr (86 kg-cal/hr)
Maximum 1170 btu/hr (295 kg-cal/hr)
Typical 341 btu/hr (86 kg-cal/hr)
Maximum 1575 btu/hr (397 kg-cal/hr
Power Supply Fan
80mm variable speed
80mm variable speed
Energy Star Compliant
X
X
Blue Angel Compliant (<5w in S5-
- Power Off)
X
X
FEMP Standby Power Compliant
(<2W in S5 - Power Off)
NOTE:
User must disable the "S5
Wake on LAN" in the F10 setup
(default is enabled).
X
X
Power Consumption in ES Mode -
Suspend to RAM (S3) (Instantly
Available PC)
2.5W to 3W
2.5W to 3W
Processor/Cache Memory Power
-Down (S3)
< 3W
< 3W
Environmental and Mechanical
Engineering Support Center
http://env-webserver.ccm.cpqcorp.net/EMESC/default.htm
QuickSpecs
HP Compaq Business Desktop dx6120 Series
Technical Specifications
DA - 12243 Worldwide — Version 21 — May 25, 2007