CSI Section 16160
Siemens Electrical Products and Systems
Specification Guide
AC
Controls
15
Key Features
쐍
Fully NEMA Rated Sizes 00–8
쐍
Double Break Contacts
쐍
Silver Tin Oxide Contacts, Cadmium-
Free (Sizes 00–5)
쐍
Higher Locked Rotor Current Ratings,
Up to 840% (Sizes 00–5)
쐍
Arc Chutes with Arc Splitters; Fast Arc
Quenching .
쐍
Lowest Contact Bounce (2
Milliseconds or less on Most Sizes)
쐍
Touch Safe Power Terminals
(Sizes 00–3)
쐍
Touch Safe Control Terminals
(Sizes 00–5)
쐍
Snap-on 2 NO and 2 NC Auxiliary
Contacts Standard (Sizes 00–5)
쐍
Visual ON / OFF indicator
쐍
Color-Coded Coils
쐍
Fast Termination System — Wire
Funnels, Wire Stops, Screwdriver
Guide Holes, and Captive Hardware
쐍
Long Mechanical Life
— 15 Million (Size 00)
— 10 Million (Size 0–5)
— 5 Million (Size 6–8)
쐍
UL Listed and CSA Certified
AC Controls
Contactors — Non-Reversing
General
Amps
Ampere Rating (Open)
Measured Parameter
8
1350
7
900
6
600
5
300
4
150
3
100
2
50
1
30
0
20
00
10
Amps
Ampere Rating (Enclosed)
1215
810
540
270
135
90
45
27
18
9
Volts
Maximum Voltage Rating
600
600
600
600
600
600
600
600
600
600
HP
Squirrel Cage
Motor Maximum
Horsepower
—
—
150
75
40
25
10
7.5
3
1.5
kW
kW
kVA
kVA
230 V, 60 Hz
200 V, 60 Hz
450
300
200
100
50
30
15
7.5
3
1.5
380 V, 50 Hz
—
—
300
150
75
50
25
10
5
1.5
460–575 V, 60 Hz
Resistive
Heating
(1-Phase
2-Pole)
240 VAC
120 VAC
480 VAC
600 VAC
Resistive
Heating
(3-Phase
3-Pole)
Capacitor
Switching
(3-Phase)
240 VAC
120 VAC
480 VAC
600 VAC
Transformer
Switching
(1-Phase
2-Pole)
240 VAC
120 VAC
480 VAC
600 VAC
Transformer
Switching
(3-Phase
3-Pole)
AC Coil
Ratings
240 VAC
208 VAC
480 VAC
600 VAC
Overall
Inrush
Sealed
240 VAC
480 VAC
600 VAC
900
600
400
200
100
50
25
10
5
2
햲
90
60
30
15
10
5
3
햲
180
120
60
30
20
10
6
햲
360
240
120
60
40
20
12
햲
450
300
150
75
50
25
15
햲
155
105
52
26
17
8.5
5
햲
315
210
105
68
34
17
10
햲
625
415
210
105
68
34
20
햲
775
515
260
130
86
43
25
360
240
160
80
40
27
12
KVAR
720
480
320
160
80
53
25
900
600
400
200
100
67
31
61
41
27
14
6.8
4.1
2.1
1.2
0.6
122
81
54
27
14
8.1
4.1
2.4
1.2
244
162
108
54
27
16
8.3
4.9
2.4
304
203
135
68
34
20
10
6.2
3
182
122
81
41
30
12
6.3
3.6
1.8
210
140
94
47
23
14
7.2
4.3
2.1
420
280
188
94
47
28
14
8.5
4.2
525
351
1350
117
59
35
18
11
5.2
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Hz
60
60
60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
VA
4200
4000
2900
2450/2960
910/1090
330/410
183/233
101/32
101/32
68/87
VA
100
140
105
115/146
58/70
32/39
17/21
12.1/16.1
12.1/16.1
10/12
MS
to 10% overvoltage,
(warm or cold coil) Total
Opening Time Includes
Arcing Time Closing Delay
Operating
Times
(valid for 20%
Undervoltage)
40–80
30–50
30–50
17–65
20–50
15–40
20–50
13–67
13–67
10–35
G/MS
Operating
140–240
10–20
10–20
18–30
20–40
15–35
15–35
15–20
15–20
15–30
AWG
Resistance To Shock (Rectangular pulse)
—
—
—
8.8/5 4.9/10
10.4/5 5.8/10
8.6/5 4.8/10
9.2/5 4.8/10
5.7/5 9/5
5.7/5 9/5
5.5/5 3.2/10
AWG
Conductor size/phase
(4) 2/0–500MC
(3) 2–600MCM
(2) 4–500
1-500MCM
2-300MCM
10–1/0
10–1/0
10–1/0
(2) 14–3
(2) 14–10
MILL
Auxiliary Contact Wire Size
(2) 18–12
(2) 18–12
(2) 18–12
(2) 18–12
(2) 18–12
(2) 18–12
(2) 18–12
(2) 18–12
(2) 18–12
(2) 18–12
Mechanical Life (make/break operations)
5
5
5
10
10
10
10
10
10
15
Total Auxiliary Contacts Available
8
8
8
8
8
8
8
4
4
4
Auxiliary Contact Rating A600/P600
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NEMA Size
Table 15.27 Contactor Technical Data
햲
For ratings contact Siemens.
Type 3TF Non-Reversing AC Contactors
NEMA Size 1
NEMA Size 3
NEMA Size 5