Product Specifications and Ordering Information
Product Specification
A-3
Environmental Specification
See page 3-5 for advice on using and storing cartridges.
Operating Limits
Non-operating Limits
Vibration and Shock Tolerance
Operating Vibration
Overstress
Operating Shock
Temperature: 10°C to 40° C (50°F to 104°F)
Humidity:
20% to 80% non-condensing
Altitude:
0 m to 9 km (0 to 30,000 ft)
Temperature:
−
40°C to 66° C (
−
40°F to 151°F)
Humidity:
10% to 95% non-condensing
Altitude:
0 m to 15 km (0 to 50,000 ft)
Vibration Type
Sine
Sweep
Frequency Range:
5–500–5 Hz
Upward and downward
Acceleration Level: 0.25g
0.010” DA
22 to 500 Hz
5 to 22 Hz (crossover)
Application:
X, Y and Z axes
Sweep rate: 1 octave per minute
Vibration Type
Sine
Sweep
Frequency Range:
5–500–5 Hz
Upward and downward
Acceleration Level: 0.50g
0.010” DA
26.1 to 500 Hz
5 to 26.1 Hz (crossover)
Application:
Vertical axis (top/bottom) Sweep rate: 1 octave per minute
Pulse Shape:
½ sine pulse
Peak Acceleration:
10g
Duration:
10 ms
Application:
X, Y and Z axes, once in each axis
dlt-m.book Page 3 Thursday, May 4, 2000 3:52 PM