• A VSF link is a logical port dedicated to the internal connection of a VSF virtual device.
• A VSF link is effective only after it is bound to a physical port.
• When an Ethernet port is bound to a VSF link, it carries VSF data traffic and VSF protocol packets.
vsf domain
Syntax
vsf domain
<DOMAIN-ID>
Description
Change a domain ID for the VSF virtual chassis.
Once VSF is enabled and virtual chassis is formed, VSF domain ID can be changed using this command.
Parameters
<DOMAIN-ID>
The VSF virtual chassis domain ID. Domain ID value can be in the range of 1 to 4294967295.
vsf member
Syntax
vsf member
<MEMBER-ID>
Description
Configure VSF member parameters.
Parameters
<MEMBER-ID>
The VSF member-ID for the member command or parameter. Member ID value can be in the range of 1 to 8.
vsf member shutdown
For a switch that physically exists, this command will cause the switch to shut down.
shutdown
is used in
preparation to remove the switch from the virtual chassis. The switch will not become a voting member of the
virtual chassis again until it is rejoined.
The
shutdown
command cannot be used on the Commander. The
shutdown
command will succeed only if the
switch physically exists and is an active member of the virtual chassis.
Syntax
vsf member
<MEMBER-ID>
shutdown
Description
Shut down the VSF virtual chassis member.
Parameters
<MEMBER-ID>
The VSF member-ID for the member command or parameter. Member ID value can be in the range of 1 to 8.
Restriction
Shutdown will not be available until VSF is enabled.
Chapter 20 Virtual Switching Framework (VSF)
657