background image

Ultra2 (LVD) SCSI adapter, single-
channel. Requires BN38C-xx cable.

Restrictions: HSZxx RAID controllers
not supported. No support for shared
SCSI.

PCI, 3.3/5.0V

Universal,

32b, 33 MHz

3X-KZPCA-AA

5/U
5/O

1/L

8:16/U
8:16/O

1:2/L

8:32/U
8:32/O

1:4/L

8:256/U

8:256/O

0/L

Backplane RAID SCSI Controllers

U320 LVD SCSI Backplane Raid
Controller, 64 bit, 2 Channel

PCI-X, 3.3V,

64b

133 MHz

3X-KZPEC-BF

5/O

8:16/O

8:32/O

8:256/O

U320 LVD SCSI Backplane Raid
Controller, 64 bit, 4 Channel

PCI-X, 3.3V,

64b

133 MHz

3X-KZPEC-DG

5/O

8:16/O

8:32/O

8:256/O

Ultra3 SCSI, 2-channel, RAID controller

PCI, 3.3V,

64b, 66 MHz

3X-KZPDC-BE

5/U

5/O

1/L

8:16/U

8:16/O

1:2/L

8:32/U

8:32/O

1:4/L

8:256/U
8:256/O

0/L

Ultra3 SCSI, 4-channel, RAID controller

PCI, 3.3V,

64b, 66 MHz

3X-KZPDC-DF

5/U

5/O

1/L

8:16/U

8:16/O

1:2/L

8:32/U

8:32/O

1:4/L

8:256/U
8:256/O

0/L

 

Cables for SCSI and
Backplane RAID
Controllers

Ultra3 SCSI cable, VHDCI to VHDCI; xx = 02, 03, 04, meters

3X-BC56J-xx

Ultra2 SCSI 68-pin HD male-to-VHDCI male cable; xx = 02, 03, 05, 10, 20
meters

BN38C-xx

Description

Device Type

Part Number

Maximum Quantity Tested & Supported

U=Tru64 UNIX

O=OpenVMS

L=Redhat V7.2 Linux

per system

per hard partition: per system

ES47

Tower

Workstation

ES47

ES80

GS1280

Fibre Channel Controllers

2-Gbit Fibre Channel Adapter, single
channel, PCI-X
LP10000, FCA2684

PCI-X, 3.3/5.0V

Universal,

64b, 133 MHz

DS-A5132-AA

5/U
5/O

28:28/U

26:28/O

56:56/U

26:56/O

64:576/U
26:576/O

2-Gbit Fibre Channel Adapter, dual
channel, PCI-X
LP10000, FCA2684DC

PCI-X, 3.3/5.0V

Universal,

64b, 133 MHz

DS-A5134-AA

5/U
5/O

28:28/U

13:26/O

32:56/U

13:56/O

32:576/U
13:416/O

CIPCA Adapter

Computer Interconnect (CI) adapter;
each CI adapter requires a Standard I/O
Building Block Drawer with 5V PCI slots.

PCI, 5V,

32b, 33 MHz,

two slots

CIPCA-BA

 

2:2/O

4:4/O

12:64/O

 

Cables for Fibre
Channel

Fibre Channel SC-SC cables (BNGBX-xx); xx=02, 03, 05, 10, 15, 30, 50 meters

BNGBX-xx

QuickSpecs

HP AlphaServer GS1280 Systems

ES/GS Common Options

DA - 11921   Worldwide — Version 24 — July 23, 2007

Page 34

Содержание AlphaServer GS1280 Systems

Страница 1: ...ption 4 System Building Block Drawer Model 8 Includes 1 drawer Model 16 includes 2 drawers 5 48 volt DC Power shelves 3 power supplies per shelf Model 8 includes 1 shelf Model 16 includes 2 shelves 6 AC input controller s mandatory option QuickSpecs HP AlphaServer GS1280 Systems Overview DA 11921 Worldwide Version 24 July 23 2007 Page 1 ...

Страница 2: ...ster Drawer mandatory option 4 System Building Block Drawer Model 32 includes four drawers 5 Power supply dual AC input is standard 6 AC input controllers two mandatory options for Model 32 QuickSpecs HP AlphaServer GS1280 Systems Overview DA 11921 Worldwide Version 24 July 23 2007 Page 2 ...

Страница 3: ...rawer is optional 4 System Building Block Drawer Model 64 includes eight drawers 5 Power supply dual AC input is standard two included for Model 64 6 AC input controllers two mandatory options for Model 64 QuickSpecs HP AlphaServer GS1280 Systems Overview DA 11921 Worldwide Version 24 July 23 2007 Page 3 ...

Страница 4: ... data paths Tru64 UNIX or OpenVMS factory installed software FIS optional high availability support with Tru64 UNIX and OpenVMS cluster solutions Product warranty 1 year hardware on site next business day and 90 day software telephone support delivered by HP Services Base Systems Contents Step 1 Requirements Step 1a System Requirements Step 1b Requirements for Partitions Step 1c Licensing Systems ...

Страница 5: ... 41U Rack Model 32 3 x 41U Rack Model 64 Boot Diagnostic Devices Load Device One slim line DVD CD RW per Master I O Drawer NOTE Only bootable CD media is supported for firmware and operating system booting Bootable DVD media is not supported Hard Drives Choice of 18 2 36 4 72 8 146 GB 300 GB SCSI disk drives in each Master I O Drawer Power Supplies 3 phase power subsystem with power cords redundan...

Страница 6: ...consulting network integration software support comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support QuickSpecs HP AlphaServer GS1280 Systems Standard Features DA 11921 Worldwide Version 24 July 23 2007 Page 6 ...

Страница 7: ...ack Service Package see ES GS Common Options Step 12 Step 1b Requirements for Partitions A single AlphaServer GS1280 can be divided into logical hardware partitions as small as two processors each running an instance of Tru64 UNIX or an instance of OpenVMS Each partition is allocated its own dedicated shared nothing set of hardware resources CPU module s memory module s and I O Each hardware parti...

Страница 8: ...tions of several hard partitions a power fault in the drawer could affect all the partitions in that drawer Hard partitions that consist of whole 8P Building Block Drawers limit the risk of a power fault in one drawer to one partition Base systems include an operating system license Tru64 UNIX or OpenVMS that licenses all hardware partitions of the system The license for an HP software product the...

Страница 9: ... CPU or faster 256 MB memory 4 GB disk space and one network interface card Intel IA 32 platform running Linux 500 MHz CPU or faster 256 GB memory 4 GB disk space and one network interface card Tru64 UNIX platform running V5 1B or later 512 MB memory 4 GB disk space and one network interface card OpenVMS platform running V7 3 1 or later 512 MB memory 4 GB disk space and one network interface card ...

Страница 10: ...72C AB AlphaServer GS1280 Dual CPU Building Block Module 2xEV7 CPUs 1150 MHz OpenVMS SMP License 3X KN72C AC Configuration and Use of instant Capacity iCAP CPUs The instant Capacity iCAP program gives HP customers the option to purchase add on CPU modules at a reduced price and install those modules in systems ready to activate instantly when needed for extra computational capacity To use the iCAP...

Страница 11: ...e including the OpenVMS SMP or Tru64 Unix SMP extension license end user product warranty iCAP software plus limited Rights to Access the CPU module and leave inactive until First Use FIRST USE First Use takes place when one or more processors on the iCAP CPU Module are activated for permanent use Temporary replacement of a failed CPU with an iCAP CPU does not constitute First Use Activation of an...

Страница 12: ...s as well as Full Use CPU Modules The system will use memory installed on the iCAP CPU Module even when the iCAP CPU is inactive Memory Application Examples The following examples illustrate different ways of configuring one 8P System Building Block Drawer with eight CPUs and a total of 16 GB of memory CPU Building Block Module 1 CPU Building Block Module 2 Case Memory Option CPU 1 CPU 2 CPU 3 CPU...

Страница 13: ...ry 1x512 RAID Option 3X MS7AB CC 3X MS7AC CC 4 GB RDRAM Memory 4x1024 Option 3X MS7AB DB 3X MS7AC DA 4 GB RDRAM Memory 1x1024 RAID Option 3X MS7AB DD 3X MS7AC DC Step 5 System I O Expansion Mandatory Configuration Guidelines Each AlphaServer GS1280 system requires one I O Master Building Block Drawer per system Additional I O Building Block Drawers are optional Each additional hard partition in th...

Страница 14: ...X slots Up to three modules may be added to the base High Performance I O Drawer 3X KFMHA AA I O 3 3 meter cable for connection between GS1280 System Building Block Drawer and I O Building Block Drawers mounted in a system rack or adjacent expansion rack select one cable for each I O drawer ordered and one cable per Add in I O Module 3X KFMHA AA if ordered 3X BNPSA 04 I O 4 5 meter cable for conne...

Страница 15: ... Drawer supports up to two optional hard disk drives See the Disks step of the ES GS Common Options section of this QuickSpec for the selection of supported disk drives Step 6 Power Distribution Units Mandatory GS1280 Model 8 GS1280 Model 16 GS1280 Model 32 GS1280 Model 64 DA DY 1280A AA DA DY 1280A BA DA DY 1280A CC DA DY 1280A BD Type A Power Distribution Units Select one variant North America J...

Страница 16: ... DY 1280A AD Dual AC Power Options for GS1280 Model 8 and Model 16 Systems Configuration Guidelines Dual AC power options can be factory configured or installed as a field upgrade The dual AC assemblies for the Model 16 requires that a second rack 3X H9A45 ZA Expansion Rack be mounted adjacent to the system power rack see Step 9 Dual AC option for use with AlphaServer GS1280 Model 8 systems 3X H75...

Страница 17: ...AlphaServer GS1280 Model 8 with Dual AC Option AlphaServer GS1280 Model 16 with Dual AC Option QuickSpecs HP AlphaServer GS1280 Systems GS Options DA 11921 Worldwide Version 24 July 23 2007 Page 17 ...

Страница 18: ...t be moved from the existing power rack to the new power rack to provide power for I O Drawers and or storage in the new power rack Dual AC option for AlphaServer GS1280 Model 32 system DA DY 1280A AC 3X H7514 BC Dual AC option for AlphaServer GS1280 Model 64 system DA DY 1280A AD 3X H7514 BD Mandatory with Dual AC options above Type B Power Distribution Units Select one variant Two required for M...

Страница 19: ...AlphaServer GS1280 Model 16 Internal System Expansion Options QuickSpecs HP AlphaServer GS1280 Systems GS Options DA 11921 Worldwide Version 24 July 23 2007 Page 19 ...

Страница 20: ...A Power Distribution Units Select one variant One required for Model 8 or Model 16 systems Second optional for Dual AC capability Two required for Model 32 and Model 64 system for Dual AC capability North America Japan 200 208V NEMA L21 30P 30A 3 x C19 outlets plus 24 x C13 outlets 3X H7606 AA International 380 415V Y IEC 309 32A 3 x C19 outlets plus 24 x C13 outlets 3X H7606 AB QuickSpecs HP Alph...

Страница 21: ...QuickSpecs HP AlphaServer GS1280 Systems GS Options DA 11921 Worldwide Version 24 July 23 2007 Page 21 ...

Страница 22: ...ference 2 Adapter to Peripheral Cross Connect Table Reference 3 Rack Specifications and Rackmount Kits Step 1 Networks and Communications Optional Step 2 Memory Channel Optional Step 3 Storage Adapters Controllers Optional Step 4 StorageWorks Enclosures for Disks and Tapes Optional Step 5 Disks Optional Step 6 Storage Systems Optional Step 7 Tape Drives Optional Step 8 Tape Storage Systems Optiona...

Страница 23: ...raphics to display quickly It is especially useful in conjunction with three dimensional 3D video and sophisticated scientific and engineering graphics programs AGP runs at several times the bus speed of conventional Peripheral Component Interconnect PCI Because of this the data transfer rate using AGP is significantly greater than with PCI video cards The AGP 4X mode provides high performance lev...

Страница 24: ...rd I O Drawers 4 8 64 128 AGP slots in Standard I O Drawers 2 4 32 64 Maximum High Performance I O Drawers One I O connection per drawer 0 2 4 32 64 Maximum High Performance I O Drawers Four I O connections per drawer 0 1 1 8 16 133 MHz PCI X PCI slots in High Performance I O Drawers 4 8 64 128 Total Slots per system per system per system per hard partition per system PCI X PCI slots 5 28 56 288 5...

Страница 25: ...CI X 66 MHz 50 MHz 66 MHz 2 66 MHz 3 3V 3 66 MHz 3 3V 4 66 MHz 3 3V 3 1 4X AGP 1 5V 1 AGP 4X Standard I O Drawer used in ES47 ES80 and GS1280 Systems For PCI X capable slots All universal or 3 3V PCI and PCI X cards are supported EXCEPT UltraSCSI wide differential adapter 32 bit 33 MHz PCI adapter 3X KZPBA CC PCI X protocol is used on the bus but reverts to PCI protocol in these cases When one or ...

Страница 26: ...If RADEON is alone in slot 1 the bus will run at 66 MHz For Port 0 slots 2 and 3 are keyed for 5V adapters High Performance I O Drawer used in ES47 ES80 and GS1280 Systems All universal or 3 3V PCI and PCI X cards are supported EXCEPT UltraSCSI wide differential adapter 32 bit 33 MHz PCI adapter 3X KZPBA CC PCI X protocol is used on the bus but reverts to PCI protocol in these cases When a PCI car...

Страница 27: ...8 Autoloader Ultrium 232 448 960 Yes Yes no no MSL2024 4048 Tape Libraries Yes Yes no no MSL6000 Tape Libraries Yes Yes no no ESL E Series Tape Libraries Yes Yes no no VSL 6000 Virtual Library System no no no no Cross Connect Table 2 Gbit Fibre Channel Adapter single channel PCI X LP10000 FCA2684 2 Gbit Fibre Channel Adapter dual channel PCI X LP10000 FCA2684DC DS A5132 AA DS A5134 AA MSA30 Rack D...

Страница 28: ... back 25 inches 25 inches 29 inches 29 inches 29 inches 29 inches Hole Pattern 0 281 Round 0 281 Round Euro Square Euro Square Euro Square Euro Square RETMA RETMA RETMA RETMA RETMA RETMA Max Payload spec d 1000 lbs 1000 lbs 1200 lbs 1600 lbs 1600 lbs 1600 lbs equipment weight only dynamic 454 kg 454 kg 544 kg 720 kg 720 kg 720 kg Height 66 9 78 7 78 7 78 7 78 7 78 7 external dim w o packaging 1700...

Страница 29: ...14 mm 914 mm 812 8 mm 1096 mm 1096 mm Shipping Depth 53 75 53 75 48 48 48 48 external dim with packaging 1366 mm 1366 mm 1219 mm 1219 mm 1219 mm 1219 mm Shipping Weight 325 lbs 355 lbs 445 lbs 284 lbs 570 lbs 570 lbs empty cab with full packaging 147 kg 161 kg 202 kg 129 kg 259 kg 259 kg RACKMOUNT KITS DS15 3X PBX01 DA 3X PBX01 DA 3X PBX01 DB 3X PBX01 DB 3X PBX01 DB1 3X PBX01 DB1 DS25 3X BA57R RA ...

Страница 30: ...Fiber with duplex SC connectors 1000 Mbps only Use BN34B or equivalent cables with SC connectors PCI X 3 3V 64 b 133 MHz 3X DEGXA SR 5 U 5 O 1 L 16 28 U 16 28 O 1 2L 16 56 U 16 56 O 1 4 L 16 512 U 16 512 O 10 100 Ethernet dual port UTP RJ45s NIC and Base Module Use BN25G BN26M BN24Q or BN28Q twisted pair RJ45 cables Optional add on daughter cards 3X DE602 TR or 3X DE602 FR PCI 3 3V 64 b 66 MHz 3X ...

Страница 31: ...nd Asynchronous Network Interface Cards Multimode fiber optic MMF 62 5 125um duplex cable with SC to SC connectors xx 2E 4E 01 03 10 20 30 for 2 4 4 5 1 3 10 20 and 30 meters BN34B xx Category 5e 4 Unshielded Twisted Pairs UTP straight through cable with RJ45 to RJ45 connectors for system to switch repeater or hub connectivity xx 0B 0E 01 03 04 07 for 0 2 0 5 1 3 4 and 7 meters BN25G xx Category 5...

Страница 32: ...ted in virtual hub mode or 3 000 meters between a controller and a hub The connection from the hub to a second system may also be 3 000 meters The CCMFB option requires a second PCI slot in the system from which it draws power only It is normally connected to the corresponding controller with the short cable BN39B 01 The CCMFB option is also used in the hub where it occupies a slot normally used b...

Страница 33: ...AA Central Europe BN19C 2E Denmark BN19K 2E Egypt India BN19S 2E Ireland United Kingdom BN19A 2E Israel 3R A6883 AA Italy BN19M 2E Japan 2 5 meter Dentori approved 3X BN46F 02 Switzerland BN19E 2E Step 3 Storage Adapters Controllers Optional Description Device Type Part Number Maximum Quantity Tested Supported U Tru64 UNIX O OpenVMS L Redhat V7 2 Linux per system per hard partition per system ES47...

Страница 34: ...o VHDCI xx 02 03 04 meters 3X BC56J xx Ultra2 SCSI 68 pin HD male to VHDCI male cable xx 02 03 05 10 20 meters BN38C xx Description Device Type Part Number Maximum Quantity Tested Supported U Tru64 UNIX O OpenVMS L Redhat V7 2 Linux per system per hard partition per system ES47 Tower Workstation ES47 ES80 GS1280 Fibre Channel Controllers 2 Gbit Fibre Channel Adapter single channel PCI X LP10000 FC...

Страница 35: ... 4300 is an Ultra3 SCSI disk drive storage enclosure The drive carrier is designed to support Ultra3 and Ultra2 hard drives and DAT Tape Drives on the same SCSI bus See HP StorageWorks 4300 Enclosure QuickSpecs for configuration details http h18000 www1 hp com products quickspecs 10624_div 10624_div HTML NOTE The depth of a 4300 shelf does not allow front and rear mounting Model 4314R Rackmountabl...

Страница 36: ... rackmount enclosure More storage can be deployed with the addition of up to two drive enclosures for a maximum storage capacity of 6 TB when using the146 GB drives Besides the single port 2 Gb Fibre Channel I O module that comes standard there is an 8 port switch that mounts internally The MSA1000 provides Ultra3 SCSI connections to the hard drives and uses HP Universal Ultra2 Ultra3 and or Ultra...

Страница 37: ...interface connections See HP StorageWorks Disk Array xp12000 QuickSpecs for configuration details http h18006 www1 hp com products quickspecs 12072_div 12072_div html Step 7 Tape Drives Optional HP StorageWorks DAT Tape Drive Family The HP StorageWorks DAT Tape Drives are an entry level solution for small to medium server storage backup needs The DAT Tape Drives have backwards compatibility with p...

Страница 38: ...ive for current DLT 40 customers offering a 100 increase in capacity Utilizing industry standard DLT Type IV Media the DLT VS80 Tape Drive offers backward read compatibility with media previously written in the DLT 40 format The DLT VS80 drive is also read and write compatible with data protection solutions utilizing the HP StorageWorks DLT1 Tape Drive such as the HP StorageWorks DLT1 1280 SuperLo...

Страница 39: ... Q1538A Ultrium LTO External tabletop Tape Drives Ultrium 232 200 GB LTO external tabletop tape drive DW065B Ultrium 448 400 GB LTO external tabletop tape drive DW017B Ultrium 920 800 GB LTO external tape drive half height device EH842A Ultrium 460 400 GB LTO external tabletop tape drive Q1520B Ultrium 960 800 GB LTO external tabletop tape drive Q1539B Step 8 Tape Storage Systems Optional HP Stora...

Страница 40: ...parison MSL2024 Ultrium 960 Tape Library MSL2024 Ultrium 920 Tape Library MSL2024 Ultrium 448 Tape Library Drive Technology Ultrium 960 SCSI Ultrium 920 Ultrium 448 Number of Drives 1 1 or 2 1 or 2 Capacity compressed 2 1 19 2 TB 19 2 TB 9 6 TB Maximum Data Transfer compressed 2 1 160 MB s 240 MB s 2 drives 96 MB s 2 drives Interface 4Gb Native Fibre Channel Ultra320 SCSI LVD SE 3Gb sec SAS Ultra3...

Страница 41: ...863_div 11863_div HTML MSL6026 MSL6030 MSL6052 MSL6060 Form Factor 5U 5U 10U 10U Tape Drives SDLT 600 Ultrium 460 or 960 SDLT 600 Ultrium 460 or 960 Number of Drives up to 2 up to 2 up to 4 up to 4 Media Slots 26 30 52 60 Storage per Library TB 15 6 24 31 2 48 Libraries per rack 8 8 4 4 Storage per Rack TB 124 8 192 0 124 8 192 0 Interface Connection Ultra3 LVD SCSI Interface or Embedded Fibre 2 G...

Страница 42: ...terface Controllers and the Interface Manager management card See HP StorageWorks ESL E Series Tape Libraries QuickSpecs for configuration details http h18006 www1 hp com products quickspecs 11877_div 11877_div html ESL 712e ESL 322e ESL 630e ESL286e Drive Technology Ultrium 960 FC Ultrium 460 SCSI Ultrium 460 FC Ultrium 960 FC Ultrium 460 SCSI Ultrium 460 FC SDLT 320 SDLT 600 SDLT 320 SDLT 600 Ma...

Страница 43: ...oducts in this family include switches from the HP StorageWorks SAN Switch 2 16 to the HP StorageWorks Core Switch 2 64 This product line includes switches with 8 16 32 and 64 ports including both full function and entry level models The HP StorageWorks Core Switch 2 64 includes a pair of independent 64 port switches in a single chassis with a high level internal redundancy The C Series product li...

Страница 44: ...ternational keyboard 3R A6554 AA Italian keyboard 3R A6555 AA 3X LK464 AI Japanese keyboard 3R A6556 AA Korean keyboard 3R A6557 AA Latin American keyboard 3R A6558 AA Norwegian keyboard 3R A6559 AA 3X LK464 AN Polish keyboard 3R A6560 AA 3X LK464 BP Portuguese keyboard 3R A6561 AA 3X LK464 AV Romanian keyboard 3X LK464 BL Simplified Chinese keyboard 3R A6562 AA Slovak keyboard 3R A6563 AA 3X LK46...

Страница 45: ... 12m 1 pack 263474 B25 Integrated Keyboard and Drawer Integrated Keyboard and Drawer 1U North America 3R A4404 AA Integrated Keyboard and Drawer 1U International 3R A4405 AA Integrated Keyboard and 17 Monitor TFT7600RKM Integrated Keyboard and Monitor North America AG052A Integrated Keyboard and Monitor United Kingdom AG053A Integrated Keyboard and Monitor Germany AG054A Integrated Keyboard and Mo...

Страница 46: ...video input connectors VGA DVI I composite video and s video Euro power cord VGA and DVI I cables 3R A6702 AA L1506 15 15 viewable image size TFT flat panel monitor 0 297 mm pixel pitch 1024 x 768 60 Hz multi mode support MPR II TCO 03 Energy Star compliant NA power cord VGA cable 3R A6515 AA Same as above Euro power cord 3R A6516 AA Monitor Power Cords North America 120V 75 inch BN26J 1K Australi...

Страница 47: ...entation of Programmable I O is not as fast as the EV68 implementation Graphics Software Tru64 UNIX Open3D license for RADEON 7500 required for 3D functionality QL 6ZRA9 AA OpenVMS Open3D license for RADEON 7500 required for 3D functionality for OpenVMS 7 3 x and earlier versions Later versions of OpenVMS include the license for 3D functionality QL 0ADA9 AA Additional Tru64 UNIX media kit for RADE...

Страница 48: ... packages include Base license Enterprise Integration Server for OpenVMS License Package Media and documentation required for first system on site Enterprise Integration Package includes licenses for TCP IP Services for OpenVMS DECwindows Motif for OpenVMS Alpha DECnet Plus for OpenVMS Alpha End System Archive Backup System for OpenVMS Management Tools Archive Backup Agent for Windows NT Office Se...

Страница 49: ...nVMS Volume shadowing license QL 2A1Ax AA OpenVMS Galaxy Galaxy Soft Partition Rules OpenVMS Galaxy hardware requirements One or more CPUs per instance One or more I O modules per instance Console port or network access per instance Memory Enough private memory for OpenVMS and applications Enough shared memory for the shared memory cluster interconnect global sections and so on Maximum of eight Ga...

Страница 50: ...port License Subscription for HP O S software and embedded L P i e EIS for OpenVMS unlimited users and server extensions for Tru64 UNIX Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their layered products Some layered products are not on the Consolidated Media Update Distribution but can be ordered separately HP Support Plus Principal Server 12 months HA109A1 aaa FP...

Страница 51: ...mer support team Remote monitoring of IT environment s stability Quarterly onsite support planning and activity report meetings Two HP technical service engagement for selected hardware environments Availability management Site environmental survey Availability checkup to assess state of IT environment against availability objectives Configuration change and release management Quarterly operating ...

Страница 52: ...ct usage info Install operating systems Product configuration Print and network access Orientation Installation and Startup HA114A1 bbb FP xSTAR yy NOTES AlphaServer ES47 ES80 and GS1280 systems include one year parts and labor warranty with 5x9 on site Next Business Day response HP Care Pack Services include support for new HP branded hardware options internal to the AlphaServer enclosure plus a ...

Страница 53: ... and integration of internal options of the server per customer specifications Installation of a single instance of either Tru64 UNIX or OpenVMS Operating System Configuration exercise and test of up to one intelligent RAID array controller and associated disks per customer requirements Testing of the system and its components for a full 100 hour burn in Mini CCD Custom Configuration Documentation...

Страница 54: ...an operating system is included in the YT VISIT B1 service subsequent partitions require the YT VISIT P1 partitioning service YT VISIT P1 Technical edit of order to guide component selection and option placement Configuration and hardware integration of the server partition per specifications Software load of either Tru64 UNIX operating system or OpenVMS operating system on a hardware software par...

Страница 55: ... Model 16 x 2 GS1280 Model 8 to Model 16 Upgrade Kit 3X BA65B AA GS1280 Model 8 AlphaServer GS1280 Upgrades for Single Systems GS1280 Model 8 to Model 16 Upgrade Kit System expansion hardware to upgrade an AlphaServer GS1280 Model 8 to an AlphaServer GS1280 Model 16 Includes one System Building Block Drawer with one power shelf with three power supplies one rackmount slide kit and associated inter...

Страница 56: ...e AlphaServer GS1280 Model 64 system NOTE Upgrade order must conform to configuration requirements for a GS1280 Model 32 system see Configuration starting at Step 3 with At least one Dual CPU Module One I O Master Drawer Power Distribution Units see Step 6 for description of choices Final configuration of the GS1280 Model 32 to Model 64 Upgrade combined with the existing GS1280 M32 must conform to...

Страница 57: ... L21 30P Hubbell 2811 IEC 32A Hubbell 532P6W Main Breaker 30A 30A 30A Sub breakers 3 x 20A 2p 1 x 20A 3p 3 x 20A 2p 1 x 20A 3p 3 x 15A 2p 1 x 15A 3p Agency UL Listed cUL UL Listed cUL TUV CB report Power Distribution Unit PDU required for GS 1280 Models 32 and 64 3X H7606 BA 3X H7606 BA 3X H7606 BB Rated Current each PDU 48A 48A 25A Typical Current each PDU 24A 25A 16A Line Connection Fixed cord p...

Страница 58: ...42 cm one 41U Rack GS1280 Model 8 GS1280 Model 16 GS1280 Model 32 GS1280 Model 64 Installed Weight base system 870 lb 395 kg 1 272 lb 577 kg 2 118 lbs 961 kg 4 800 lbs 2 176 kg Heat dissipation Max Heat Output Base Model only watts 3 405 6 810 14 820 28 440 Max heat Output Base Model only Btu hr 11 622 23 243 50 581 97 066 Typical Heat Output Base Model only watts 2 430 3 700 8 000 14 800 Typical ...

Страница 59: ... I O Drawer GS1280 Model 16 1 I O Drawer GS1280 Model 32 1 I O Drawer GS1280 Model 64 1 I O Drawer Idle Operating LwAd B 7 1 6 9 7 4 7 6 7 7 7 9 Bystander pos LpAm dBA 51 53 55 57 58 60 NOTE Current values for specific configurations are available 1 B 10 dBA Copyright 2007 Hewlett Packard Development Company L P The information contained herein is subject to change without notice UNIX is a registe...

Отзывы: