Plug the power cord into the appropriate receptacle on the rear of the chassis to achieve the
standby power state; the front panel Power button is not turned on. Full power occurs when the
power cord is plugged into the appropriate receptacle, and either the power is activated through
the iLO 2 MP
PC
command, or the Power button is activated. In the off state, the power cords
are not plugged in.
lists the server power states.
Table 27 Power States
DC Voltage
Applied
AC Voltage
Applied
Power Activated through the iLO 2 MP
PC
Command or Front Panel Power
Button Activated
Power Cable
Plugged Into
Receptacle
Power States
No
Yes
No
Yes
Standby power
Yes
Yes
Yes
Yes
Full power
No
No
No
No
Off
NOTE:
If the power restore feature is set to
Always On
through the iLO 2 MP
PR
command,
the server can automatically power on to the full power state.
Attaching the Hook-and-Loop Strap to the Bulk Power Supply and Power Cord
CAUTION:
If you do not fasten the hook-and-loop strap to the bulk power supply and the power
cord, the power cord might pop off the back.
To attach the hook-and-loop strap to the bulk power supplies and power cord, follow these steps:
1.
Attach the hook-and-loop strap to the handle on the bulk power supply.
2.
Attach the other end of the strap to the power cord (
).
Figure 34 Fastening the Power Supply
74
Installing the System