8.
Install the DIMM (
a.
Align the DIMM with the correct slot on the memory board, and align the key in the
connector with the notch in the DIMM.
b.
Firmly and evenly push on each end of the DIMM until it seats into the slot.
c.
Ensure the extraction levers are in the locked position.
Figure 71 Inserting DIMM into Memory Board Connector
9.
Replace the memory carrier assembly side cover.
a.
Insert the side cover tabs into the retaining slots at the base of the assembly (
).
b.
Insert the tabs (
) into the slots on both sides of the extraction handle release
button until the side cover snaps into place.
NOTE:
To install DIMMs into slots on the other side of the memory carrier, turn the carrier
over to the opposite side (side 0 or side 1) and repeat the installation procedure.
10. Replace the memory carrier assembly and latch the top cover release lever closed. See
“Replacing the Memory Carrier Assembly” (page 205)
.
11. If rack installed, slide the server completely into the rack. See
“Inserting the Server into the
.
12. Reconnect the power cables and power on the server. See
Removing and Replacing the Front Bezel
The front bezel provides server control and port access, and LED interfaces. You must power
off the server to remove the front bezel.