Step 3:

Verify hub operation.

Before racking the FC-AL hub, make sure it is 
operationa1. 

1.  Plug one end of the PDU cable into the hub 

and the other into an appropriate power source 
(100 VAC or 240 VAC). 

2.  At the completion of the hub self test (15 sec.), 

the Power LED should be on and the Fault 
LED off.

• If the hub passes the self test, unplug the 

cable and continue with the installation.

• If the self test fails, see the troubleshooting 

section of the HP Fibre Channel Arbitrated 
Loop Hub Service and User Manual

Step 4:

Mount the rails.

1.  Slide a sheet metal nut on the outer back 

column at the selected rack location. Insert the 
tab of the left rail in the adjacent slot so that the 
holes on the rack, nut, and rail are aligned. 

Figure 3

2.  Attach the other end of the rail to the inner 

front column using another sheet metal nut and 
the same procedure.

NOTE: Do NOT attach screws at this time.

3.  Repeat items 1 and 2 to install the right rail.

Step 5:

Mount the hub on the rails.

1.  Slide the hub into the rails with the FC ports 

facing the rear of the cabinet. 

2.  Align the mounting ear brackets on the hub 

with the rear holes in the assembled rails, and 
fasten with two 10-32 x .625 screws. 

Figure 4

Step 6:

Install the plenum shroud.

1.  Slide the plenum shroud onto the rails from the 

front of the rack. 

2.  Align the plenum shroud brackets with the 

front holes in the assembled rails and secure 
with the two remaining 10-32 x .625 screws.

Figure 5

Step 7:

Plug in the hub.

Attach the PDU cable to the receptacle on the hub 
and to the cabinet power source (PDU). Verify 
that the hub passes the self test.

Replace filler panels over the plenum shroud to 
complete the installation.

To attach FC-AL devices, refer to the Hewlett-Packard Fibre Channel 
Arbitrated Loop Service and User Manual
 (A3724-90006). 