Component identification 75
Description
Status
NIC LEDs
Off = No link to network
Solid green = Network link
Flashing green = Network link with activity
If power is off, the front panel LED is not active. For
status, see "Rear panel LEDS and buttons (on page
)."
Power supply
LEDs
Off = Normal
Solid amber = Power subsystem degraded, power
supply failure, or input power lost.
PCI riser LED
Off = Normal
Amber = Incorrectly installed PCI riser cage
Over temp LED
Off = Normal
Amber = High system temperature detected
Amp Status LED
Off = AMP modes disabled
Solid green = AMP mode enabled
Solid amber = Failover
Flashing amber = Invalid configuration
Power cap LED
Off = System is in standby, or no cap is set.
Solid green = Power cap applied
For more information, see "Systems Insight Display LED combinations (on page
)."
Systems Insight Display LED combinations
When the health LED on the front panel illuminates either amber or red, the server is experiencing a
health event. Combinations of illuminated Systems Insight Display LEDs, the system power LED, and the
health LED indicate system status.
Systems Insight
Display LED and
color
Health LED System power
LED
Status
Processor (amber)
Red
Amber
One or more of the following conditions may
exist:
•
Processor in socket
X
has failed.
•
Processor
X
is not installed in the
socket.
•
Processor
X
is unsupported.
•
ROM detects a failed processor during
POST.
Processor (amber)
Amber
Green
Processor in socket
X
is in a pre-failure
condition.
DIMM (amber)
Red
Green
One or more DIMMs have failed.
DIMM (amber)
Amber
Green
DIMM in slot
X
is in a pre-failure condition.
Over temp (amber)
Amber
Green
The Health Driver has detected a cautionary
temperature level.
Over temp (amber)
Red
Amber
The server has detected a hardware critical
temperature level.
PCI riser (amber)
Red
Green
The PCI riser cage is not seated properly.
Fan (amber)
Amber
Green
One fan has failed or has been removed.
Fan (amber)
Red
Green
Two or more fans have failed or been
removed.
Power supply (amber)
Red
Amber
One or more of the following conditions may
exist:
•
Only one power supply is installed and