![HP 5800-24G Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/hp/5800-24g/5800-24g_quickspecs_162948014.webp)
MAC address table size
MAC address table size
MAC address table size
MAC address table size
32000 entries
Environment
Environment
Environment
Environment
Operating temperature
Operating temperature
Operating temperature
Operating temperature
32°F to 113°F (0°C to 45°C)
Operating relative
Operating relative
Operating relative
Operating relative
humidity
humidity
humidity
humidity
10% to 90%
Acoustic
Acoustic
Acoustic
Acoustic
Low-speed fan: 54 dB, High-speed fan: 58.5 dB
Electrical characteristics
Electrical characteristics
Electrical characteristics
Electrical characteristics
Maximum heat dissipation
Maximum heat dissipation
Maximum heat dissipation
Maximum heat dissipation 6278 BTU/hr (6623.29 kJ/hr)
Voltage
Voltage
Voltage
Voltage
100-120/200-240 VAC
DC Voltage
DC Voltage
DC Voltage
DC Voltage
300 W DC: –48 VDC to –60 VDC; 750 W DC: –54 VDC to –57 VDC
Frequency
Frequency
Frequency
Frequency
50/60 Hz
Safety
Safety
Safety
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2;
IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR
Subchapter J; NOM; ROHS Compliance
Emissions
Emissions
Emissions
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR22 Class A;
EN 61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC
(CFR 47, Part 15) Class A
Immunity
Immunity
Immunity
Immunity
Generic
Generic
Generic
Generic
ETSI EN 300 386 V1.3.3
EN
EN
EN
EN
EN 55024:1998+ A1:2001 + A2:2003
ESD
ESD
ESD
ESD
EN 61000-4-2; IEC 61000-4-2
Radiated
Radiated
Radiated
Radiated
EN 61000-4-3; IEC 61000-4-3
EFT/Burst
EFT/Burst
EFT/Burst
EFT/Burst
EN 61000-4-4; IEC 61000-4-4
Surge
Surge
Surge
Surge
EN 61000-4-5; IEC 61000-4-5
Conducted
Conducted
Conducted
Conducted
EN 61000-4-6; IEC 61000-4-6
Power frequency
Power frequency
Power frequency
Power frequency
magnetic field
magnetic field
magnetic field
magnetic field
IEC 61000-4-8; EN 61000-4-8
Voltage dips and
Voltage dips and
Voltage dips and
Voltage dips and
interruptions
interruptions
interruptions
interruptions
EN 61000-4-11; IEC 61000-4-11
Harmonics
Harmonics
Harmonics
Harmonics
EN 61000-3-2, IEC 61000-3-2
Flicker
Flicker
Flicker
Flicker
EN 61000-3-3, IEC 61000-3-3
Management
Management
Management
Management
IMC - Intelligent Management Center; command-line interface; Web browser; SNMP Manager; Telnet;
HTTPS; RMON1; FTP
Notes
Notes
Notes
Notes
Customer must order power supply, as the device does not come with a PSU. At least one
JC087A/JC090A/JC089A is required.
Services
Services
Services
Services
3-year, 4-hour onsite, 13x5 coverage for hardware (HQ063E)
3-year, 4-hour onsite, 24x7 coverage for hardware (HQ064E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 SW phone support and SW updates
(HQ067E)
3-year, 24x7 SW phone support, software updates (HQ066E)
1-year, post-warranty, 4-hour onsite, 13x5 coverage for hardware (HR569E)
1-year, post-warranty, 4-hour onsite, 24x7 coverage for hardware (HR570E)
Installation with minimum configuration, system-based pricing (UW451E)
4-year, 4-hour onsite, 13x5 coverage for hardware (HQ068E)
4-year, 4-hour onsite, 24x7 coverage for hardware (HQ069E)
4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (HQ076E)
4-year, 24x7 SW phone support, software updates (HQ074E)
5-year, 4-hour onsite, 13x5 coverage for hardware (HQ071E)
5-year, 4-hour onsite, 24x7 coverage for hardware (HQ072E)
QuickSpecs
HP 5800 Switch Series
HP 5800 Switch Series
HP 5800 Switch Series
HP 5800 Switch Series
Technical Specifications
DA - 13807 North America — Version 7 — November 16, 2011