26
Power supply Connection
procedure reference
PSR150-D (JD366A)
PSR150-D1 (JD366A)
Connecting the PSR150-D/PSR150-D1
PSR720-56A (JG544A)
PSR1110-56A (JG545A)
Connecting the PSR720-56A/PSR1110-56A
CAUTION:
The AC power cord for the PSR150-A/PSR150-A1 uses C13 connector, while the AC power cord for the
PSR720-56A/PSR1110-56A uses high-temperature C15 connector. Do not mix them.
Connecting the PSR150-A/PSR150-A1
The following takes the PSR150-A as an example. The connection procedure for the PSR150-A1 is similar.
To connect the PSR150-A:
1.
Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well
grounded.
2.
Connect one end of the AC power cord supplied with the power supply to the power receptacle on
the power supply (see
3.
Connect the other end of the AC power cord to an AC power outlet.
Figure 37
Connecting the PSR150-A
Connecting the PSR150-D/PSR150-D1
WARNING!
Identify the positive (+) and negative (-) marks on the two wires to avoid connection mistakes.
The following takes the PSR150-D as an example. The connection procedure for the PSR150-D1 is similar.
To connect the PSR150-D:
1.
Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well
grounded.
2.
Unpack the DC power cord, correctly orient the plug at one end of the cable with the power
receptacle on the power supply, and insert the plug into the power receptacle (see callout 1
).