The HP StorageWorks DAT SCSI drives come in two variants that increase your uptime: hot-plug and
offline hot-swap. With these configurations, you never have to take down your system to replace a failed
or non-responding tape device.

Hot-plug tape drives are supported on all HP ProLiant and AlphaServers that have the universal drive
bay built in to the server. These drives can be inserted or removed without disassembling the server, thus
enabling the system to be operational 24x7. This configuration also provides the ability to mix tape
drives and 1" hot-plug hard drives on the same SCSI bus without slowing down the performance of the
system (supported on the HP Smart Array 5300 controller family and integrated Smart Array controller
and selected HP AlphaServer host bus adapters).

The HP StorageWorks Tape Array 5300 supports "offline hot-swap" (sometimes referred to as "warm-
swap") array modules, including DAT drives. This means the drives can be removed and replaced with
the power on and the SCSI cables attached to the server. Because the array's SCSI buses are not
buffered, however, drive replacement should only take place while the SCSI bus is quiescent (no SCSI
activity from the tape drive or any other device on the same bus). This is similar to HP hot-plug DAT
drives, though the hot-plug drives are not affected by other devices on the bus.

With the HP StorageWorks DAT hot-plug tape drives or array modules, the server does not need to be
taken offline to install the tape drive. Simply insert the tape drive into the server's hot-plug bay or the
Tape Array 5300's drive bay and install or configure the backup software.

Rack-Mount Tape

Rack-Mount Tape

Rack-Mount Tape

Rack-Mount Tape
Options

Options

Options

Options

HP DAT SCSI drives are supported on the HP StorageWorks 1U and 3U Rack-Mount Kits and the HP
StorageWorks Tape Array 5300. The 3U Rack-Mount Kit and the Tape Array 5300 allow up to four
internal DAT drives to be installed in 3U of rack space, while the 1U Rack-Mount Kit holds two DAT
drives in 1U of space. Both the 1U and 3U rack-mount kits use standard internal DAT SCSI drives for a
low-cost solution, while the Tape Array 5300 uses DAT array modules that provide offline hot-swap
capabilities and redundant components for high-availability environments.

Either of these rack enclosures can be configured with separate SCSI buses (channels) for each drive or
two or more drives per bus using the optional cable kits.

NOTE:

NOTE:

NOTE:

NOTE: Please refer to the QuickSpecs for HP StorageWorks Rack-Mount Kits at

http://h18000.www1.hp.com/products/quickspecs/10854_div/10854_div.html

or the HP StorageWorks Tape Array 5300 web page at

http://www.hp.com/products1/storage/products/tapebackup/tapearrays/tapearray5300/index.html

for further information.

QuickSpecs

HP StorageWorks DAT Drives

HP StorageWorks DAT Drives

HP StorageWorks DAT Drives

HP StorageWorks DAT Drives

Product Highlights

DA - 11883   Worldwide — Version 15 — March 20, 2006

Page 10

Содержание 40 SCSI

Страница 1: ...ress Single Server Edition backup recovery software and the HP StorageWorks Data Protector Express Bare Metal Disaster Recovery option Data Protector Express Single Server Edition is an easy to use backup application to protect a single Windows Linux or NetWare server HP s unique Library and Tape Tools L TT utilities provide HP StorageWorks DAT customers with a comprehensive suite of tape drive ma...

Страница 2: ...rks DAT 40 USB Tape Drive DAT 40 USB Tape Drive DAT 40 USB Tape Drive DAT 40 USB Tape Drive The HP StorageWorks DAT 40 USB Tape Drive is a dependable entry level backup solution for smaller servers and workstations This DDS 4 tape drive stores 40 GB of compressed data on a single cartridge at a rate of 23 GB hr assuming 2 1 data compression providing an ideal balance between capacity and performan...

Страница 3: ...nternal Tape Drive DAT 72 SCSI 3 External Tape Drive HP StorageWorks HP StorageWorks HP StorageWorks HP StorageWorks DAT 72 USB Tape Drive DAT 72 USB Tape Drive DAT 72 USB Tape Drive DAT 72 USB Tape Drive The HP StorageWorks DAT 72 USB tape drive provides an optimum balance of dependable backup capacity and low cost of ownership for small and medium businesses remote offices and workgroups The DAT...

Страница 4: ... 72 USB Internal Tape Drive NOTE NOTE NOTE NOTE 0D1 will appear after this part number on your sales order if factory integration is indicated DW026A DAT 72 USB External Tape Drive DW027A Key Features Key Features Key Features Key Features Based on industry standard DDS technology the most popular server backup technology of all time providing customers will all the benefits of an open standard in...

Страница 5: ...st way to restore data in the event of a disaster Affordable Affordable Affordable Affordable inexpensive media contributes to an exceptionally low cost of ownership Manageable Manageable Manageable Manageable includes superior management capabilities that makes it easy to install use and support Low maintenance Low maintenance Low maintenance Low maintenance automatic head cleaning system reduces...

Страница 6: ...ity can be achieved for a given length of tape because no guard bands are necessary The data format also allows for fast location of tracks and data To achieve this the rotating drum is tilted at a slight angle 6 from the vertical The drum has four heads two write heads and two read heads located at 90 intervals For each rotation of the drum two tracks are written The read heads verify the data th...

Страница 7: ... DDS 3 and DDS 2 DAT 24 also reads and writes DDS 2 and DDS 1 NOTE NOTE NOTE NOTE The DAT 40 hot plug drive is an exception This drive is read write compatible with DDS 3 and read compatible with DDS 2 NOTE NOTE NOTE NOTE The DAT 24 USB drive does not read or write DSS 1 QuickSpecs HP StorageWorks DAT Drives HP StorageWorks DAT Drives HP StorageWorks DAT Drives HP StorageWorks DAT Drives Product H...

Страница 8: ...ate 1 bit in 10 17 DAT s MTBF is now typically expressed with a 100 duty cycle to make it simpler to compare to other tape formats for example HP s enterprise level LTO Ultrium drives have an MTBF of 250 000 hours at a 100 duty cycle In practice however unlike Ultrium drives used 24x7 as the most popular choice for large tape libraries few DAT drives would ever be used 24 hours a day Using a 12 du...

Страница 9: ...re widely available reducing the conflict between devices over scarce connectors Port expansion is easy USB hubs can be installed to add additional ports supporting up to 127 devices on a system Low cost reliable connectivity By providing native USB DDS DAT drives there is no need for customers to purchase additional host bus adapters HP s USB 2 0 implementation benefits from the built in reliabil...

Страница 10: ...y other device on the same bus This is similar to HP hot plug DAT drives though the hot plug drives are not affected by other devices on the bus With the HP StorageWorks DAT hot plug tape drives or array modules the server does not need to be taken offline to install the tape drive Simply insert the tape drive into the server s hot plug bay or the Tape Array 5300 s drive bay and install or configu...

Страница 11: ... is a special SKU only available for new customers of HP StorageWorks tape products that gives a significant discount off Data Protector Express to recognise the value of the in box software Upgrading to Data Protector Express allows network backup of servers and Windows desktops extends the disk to disk backup capacity and capability and permits the additions of agents and extensions to increase ...

Страница 12: ...including third party systems visit http www hp com go connect for the latest hardware compatibility information NOTE NOTE NOTE NOTE HP recommends that no more than one DAT USB tape drive be connected to a system at a time OS Support for SCSI DAT OS Support for SCSI DAT OS Support for SCSI DAT OS Support for SCSI DAT drives drives drives drives Microsoft Windows Novell NetWare HP UX Linux various ...

Страница 13: ...and Technical Support visit ftp ftp compaq com pub products storageworks warranty EN_321708 008 pdf HP Care Pack Services HP Care Pack Services HP Care Pack Services HP Care Pack Services HP Care Pack Services offer upgraded service levels to extend and expand your standard product warranty with easy to buy easy to use support packages that help you make the most of your hardware and software inve...

Страница 14: ...vices Services Extend your product warranty with a wide choice of cost saving support packages HP Care Pack services are sold by HP and HP authorized enterprise and commercial resellers Services for customers purchasing via direct and enterprise resellers are quoted using HP order configuration tools Additional information about HP Care Pack service features and benefits is available at http www h...

Страница 15: ...duct Numbers Product Numbers Enterprise Commercial Purchased Care Packs Enterprise Commercial Purchased Care Packs Enterprise Commercial Purchased Care Packs Enterprise Commercial Purchased Care Packs A stands for physical Care Pack E for electronic Care Pack For DAT 40 USB DAT 40 SCSI DAT 72 USB and DAT 72 SCSI For DAT 40 USB DAT 40 SCSI DAT 72 USB and DAT 72 SCSI For DAT 40 USB DAT 40 SCSI DAT 7...

Страница 16: ...nd DAT 72 SCSI For DAT 40 USB DAT 40 SCSI DAT 72 USB and DAT 72 SCSI For DAT 40 USB DAT 40 SCSI DAT 72 USB and DAT 72 SCSI For DAT 40 USB DAT 40 SCSI DAT 72 USB and DAT 72 SCSI Product Number Product Number Product Number Product Number Product Description Product Description Product Description Product Description Drive Band Drive Band Drive Band Drive Band Install Band Install Band Install Band ...

Страница 17: ...asis SW is supported separately per package The Care Pack information quoted above relates to 3 year offerings only 1yr 4yr 5yr packs are available for each offering replace A3 with A1 A4 or A5 eSupport eSupport eSupport eSupport HP eSupport is a portfolio of technology based services that assist you with managing your business environment from the desktop to the data center Support Portal Support...

Страница 18: ...s storage For more information about HP Care Pack services for storage products visit http www hp com hps carepack storage cp_networked html For more information about HP storage software services and updates visit http h18006 www1 hp com storage software html If you have specific questions contact your local HP representative Contact information for a representative in your area can be found at C...

Страница 19: ...s Bare Metal Disaster Recovery option SCSI ribbon cable power extender cable screws HP DDS 4 data cartridge HP DDS cleaning cartridge NOTE NOTE NOTE NOTE 0D1 will appear after this part number on your sales order if factory integration is indicated C5686C DAT 40 SCSI External DAT 40 SCSI External DAT 40 SCSI External DAT 40 SCSI External DAT 40 SCSI External Tape Drive installation guide HP Storag...

Страница 20: ...ing cartridge NOTE NOTE NOTE NOTE 0D1 will appear after this part number on your sales order if factory integration is indicated Q1522B DAT 72 SCSI External DAT 72 SCSI External DAT 72 SCSI External DAT 72 SCSI External DAT 72 SCSI External 100 ROHS Compliant Tape Drive installation poster HP StorageWorks CD containing electronic user s guide drivers and HP Library and Tape Tools software diagnost...

Страница 21: ...E NOTE NOTE 0D1 will appear after this part number on your sales order if factory integration is indicated DW026A DAT 72 USB External DAT 72 USB External DAT 72 USB External DAT 72 USB External DAT 72 USB External Tape Drive installation poster HP StorageWorks CD containing electronic user s guide drivers and HP Library and Tape Tools software diagnostics HP StorageWorks Data Protector Express Sin...

Страница 22: ...404 256 Controller NOTE NOTE NOTE NOTE Supports hot plug tape drives only 273914 B21 Host Bus Adapters and Host Bus Adapters and Host Bus Adapters and Host Bus Adapters and Controllers for Controllers for Controllers for Controllers for AlphaServers AlphaServers AlphaServers AlphaServers 32 bit Single Channel Ultra Wide HBA NOTE NOTE NOTE NOTE Not supported with hot plug NOTE NOTE NOTE NOTE Suppor...

Страница 23: ...page for further information http h18006 www1 hp com products storageworks 3urackmount index html 274338 B22 Tape Array 5300 NOTE NOTE NOTE NOTE Tape Array 5300 holds up to four offline hot swap DAT array modules and other tape technologies NOTE NOTE NOTE NOTE Please refer to the following web page for further information http www hp com products1 storage products tapebackup tapearrays tapearray53...

Страница 24: ... HxWxD USB USB USB USB External External External External 11 8 x 11 02 x 12 6 in 30 0 x 28 0 x 32 0 cm 11 8 x 11 02 x 12 6 in 30 0 x 28 0 x 32 0 cm 11 8 x 11 02 x 12 6 in 30 0 x 28 0 x 32 0 cm Shipping Shipping Shipping Shipping HxWxD Hot Plug Hot Plug Hot Plug Hot Plug N A 5 5 x 9 0 x 9 1 in 14 0 x 22 5 x 23 1 cm 14 2 x 10 0 x 11 0 in 36 0 x 25 0 x 28 0 cm Shipping Shipping Shipping Shipping HxW...

Страница 25: ... s synchronous Burst Transfer Rate Burst Transfer Rate Burst Transfer Rate Burst Transfer Rate SCSI 3 interface Where 1KB 1 000 Bytes N A N A 6 4 MB s asynchronous 160 MB s synchronous Burst Transfer Rate Burst Transfer Rate Burst Transfer Rate Burst Transfer Rate USB interface Where 1KB 1 000 Bytes 6 4MB s asynchronous 40 MB s synchronous 6 4MB s asynchronous 40 MB s synchronous 6 4 MB s asynchro...

Страница 26: ...rd read write Backward read write Backward read write Backward read write compatibility compatibility compatibility compatibility USB DDS 2 120m DDS 3 125m DDS 2 120m DDS 4 155m DDS 3 125m Tape Format Tape Format Tape Format Tape Format DAT 24 DAT 24 DAT 24 DAT 24 DAT 40 DAT 40 DAT 40 DAT 40 DAT 72 DAT 72 DAT 72 DAT 72 Recording Method Recording Method Recording Method Recording Method 4 mm helica...

Страница 27: ...s Power Requirements SCSI 2 internal hot plug and array module 5V 5 100mV Max ripple 1 2A 12V 10 150mV Max ripple 0 1A 5V 5 100mV Max ripple 0 6A 12V 10 150mV Max ripple 1 2A 5V 5 100mV Max ripple 0 6A 12V 10 150mV Max ripple 1 2A Power Requirements Power Requirements Power Requirements Power Requirements USB and SCSI 3 internal and array module 5V 5 100mV Max ripple 0 8A 12V 10 150mV Max ripple 0...

Страница 28: ...e tape heads need cleaning If the media caution signal appears after using a cleaning cartridge the cleaning cartridge has probably expired and should be discarded Error Condition Signal Error Condition Signal Error Condition Signal Error Condition Signal Off On steady HP DAT drives perform a comprehensive self test during power up If a hard error causes the self test to fail the clean light chang...

Отзывы: