![background image](http://html.mh-extra.com/html/hp/3600-v2-series/3600-v2-series_installation-manual_162919020.webp)
Grounding the switch with a grounding strip
When a grounding strip is available at the installation site, connect the grounding cable to the
grounding strip.
CAUTION:
•
The supplied grounding cable of the 3600 v2 Switch Series does not have an auxiliary OT terminal.
•
Connect the grounding cable to the earthing system in the equipment room. Do not connect it to a fire
main or lightning rod.
Connecting the grounding cable to the switch
Follow these steps to connect the grounding cable:
1.
Remove the grounding screw on the rear panel of the switch chassis.
2.
Attach the grounding screw to the OT terminal of the grounding cable.
3.
Use a screwdriver to fasten the grounding screw into the grounding screw hole.
Figure 22
Connect the grounding cable to the grounding hole of switch
6
5
4
1
2 3
(1) Chassis rear panel
(2) Grounding sign
(3) Grounding hole
(4) OT terminal
(5) Grounding cable
(6) Grounding screw
Connecting the grounding cable to a grounding strip
Follow these steps to connect the grounding cable to a grounding strip:
1.
Remove the hex nut from the grounding strip.
2.
Cut the grounding cable to a proper length according to the distance between the switch and the
grounding strip.
3.
Make the connector on the grounding cable:
15