background image

Installing the control unit in the rack 

The control unit can be mounted in the rack two different ways, 

depending on whether you install the 0U brackets (A) or the 1U 

brackets (B) to the control unit. 

 

 

Installing the control unit in a square-holed 

rail 

  

 

NOTE:

  Use the M6 screws and cage nuts that shipped 

with the rack when installing in a square-holed rail. 

  

 

 

Installing the control unit in a square- and 

round-holed rail 

  

 

NOTE:

  Use the sheet metal mounting screws that are 

included with this kit when installing in a square- and 

round-holed rail. 

  

 

 

Installing the extension bars (if 

included) 

The cord retention brackets are shown for clarification in the 
following diagrams, though installation of the cord retention brackets 

is optional. 

  

 

NOTE:

  Follow these same instructions when using a single-

wide extension bar bracket. 

Содержание 252663-B24 - PDU Power Distribution Strip

Страница 1: ...ts circuit breakers move to Off position minimizing downtime Power cord retention Recessed handles to prevent inadvertent power off The extension bars if included provide the following features Multiple power outlets conveniently located for quick and easy equipment power connections Lighted main power indicator Attached 2 m 6 ft input power cords Power cord retention and power cord labeling Modul...

Страница 2: ...ceed the total output rating marked on the mPDU WARNING To reduce the risk of personal injury from high leakage current verify earth connection before connecting the power supply The summation of input power for multiple pieces of information technology equipment through the use of power products can result in high leakage currents If the total system leakage current for a system of components exc...

Страница 3: ...TL 4 8 4 40 6 252663 D74 NA JPN 0 0 0 6 252663 B33 INTL 0 0 0 6 252663 D75 NA JPN 0 0 0 6 252663 B34 INTL 0 0 0 6 AF500A 2 4 2 40 0 AF501A 2 4 2 40 0 AF511A 0 0 0 6 Model Number of extension bars Number of single double brackets Number of extension bar power cord retention bands Number of control unit tie wraps AF512A 0 0 0 6 AF513A 0 0 0 6 AF518A 0 0 0 6 AF519A 0 0 0 6 Required tools The followin...

Страница 4: ...Installing the 0U brackets Installing the 1U brackets ...

Страница 5: ... the rack when installing in a square holed rail Installing the control unit in a square and round holed rail NOTE Use the sheet metal mounting screws that are included with this kit when installing in a square and round holed rail Installing the extension bars if included The cord retention brackets are shown for clarification in the following diagrams though installation of the cord retention br...

Страница 6: ...Installing the extension bars using single stick mounting brackets Connecting and securing the power cords ...

Страница 7: ...n bars and control unit Control unit Total rating of control unit Outlet style Load CB rating Individual outlet rating 228481 001 24 A IEC 320 C19 15 A 12 A 228481 002 24 A IEC 320 C19 15 A 12 A 228481 003 32 A IEC 320 C19 15 A 12 A 228481 004 40 A IEC 320 C19 15 A 12 A 228481 006 16 A IEC 320 C19 10 A 8 A 228481 007 40 A IEC 320 C19 15 A 12 A 228481 008 40 A IEC 320 C19 15 A 12 A 435530 001 41 6 ...

Страница 8: ......

Отзывы: