HP 200529-001 - Wireless Access Point Скачать руководство пользователя страница 11

 

Specifications 11 

Specifications 

HP NC112T PCI Express Gigabit Server Adapter 

specifications 

       

Specification Value 

Network Controller Chipsets  Intel® 82574L 
Bus Type 

x1 PCI Express v1.1 (2.5 GTps) 

Bus Width 

One lane (x1) 

On-board Memory 

32 KB 

Data Transfer Method 

Bus Master DMA 

Boot ROM Support 

Yes 

Management Capabilities 

WOL, PXE 2.2, ACPI 1.0 (Note: WOL and PXE are set to the default of off) 

Power Requirement 

575 mA  @ 3.3 VDC max 

Data Transmission Rate 

10 Full/10 Half, 100 Full/100 Half, 1000 Full 

Standards Supported 

IEEE 802.3u, IEEE 802.3x (flow control), IEEE 802.3ad (link aggregation), IEEE 
802.1p (QoS), IEEE 802.1q (VLAN tagging), IEEE802.3z, IEEE802.3ap, 

IEEE802.3ae 

Dimensions 

11.93 cm x 5.58 cm [4.7 in x 2.2 in (L x W)] (without bracket) 

Connector and Distances 

10BASE-T: Category 3, 4, or 5 UTP 100 M (328 ft) 
100BASE-TX: CAT5 UTP 100 M (328 ft) 
1000BASE-TX: CAT5 UTP 100 M (328 ft) 

Interrupts Supported 

Automatically configured 

Temperature Range 

Operating: 0°C to 55°C (32°F to 131°F)  
Storage: -40°C to 85°C (-40°F to 185°F)   

Relative Humidity (non-
condensing) 

Operating: 10% to 95% 
Storage: -5% to 95% 

Safety Compliance 

UL Mark (US and Canada) 
CE Mark 
EN60950 
RoHS (European Union) 

 

 

UTP cable specifications 

The NC112T adapter can use existing UTP CAT5 (or better) cable to deliver Gigabit Ethernet over 

copper, according to the IEEE 802.3ab specifications. For new installations, CAT5e (enhanced CAT5) 

cable is recommended. 

Содержание 200529-001 - Wireless Access Point

Страница 1: ...HP NC1 12T PCI Express Gigabit Server Adapter User Guide Part Number 509365 00A March 2009 First Edition ...

Страница 2: ... herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Intel is a registered trademark of Intel Corporation Intended audience This document is for the person who installs administers and troubleshoots servers and storage systems HP assumes you are qualified in the servicing of computer equipment and ...

Страница 3: ... UTP cable specifications 11 Regulatory compliance notices 13 Regulatory compliance identification numbers 13 Federal Communications Commission notice 13 Class B equipment 13 Declaration of conformity for products marked with the FCC logo United States only 14 Modifications 14 Canadian notice 14 European Union regulatory notice 14 Japanese class B notice 15 Korean class B notice 15 Disposal of was...

Страница 4: ...nd hazards associated with the product WARNING To reduce the risk of electric shock or damage to the equipment Do not disable the power cord grounding plug The grounding plug is an important safety feature Plug the power cord into a grounded earthed electrical outlet that is easily accessible at all times Unplug the power cord from the power supply to disconnect power to the equipment Do not route...

Страница 5: ...cal support In the United States for contact options see the Contact HP United States webpage http welcome hp com country us en contact_us html To contact HP by phone o Call 1 800 HP INVENT 1 800 474 6836 This service is available 24 hours a day 7 days a week For continuous quality improvement calls may be recorded or monitored o If you have purchased a Care Pack service upgrade call 1 800 633 360...

Страница 6: ... supported option for selected HP ProLiant servers The adapter must be installed in a PCI Express slot The NC112T adapter supports IPv4 and IPv6 offload For the latest functionality features and operating system support for this adapter see the HP website http h18004 www1 hp com products servers networking index nic html UTP CAT5 cable The NC112T adapter can use existing UTP CAT5 or better cable t...

Страница 7: ...cable connection is working Off No link to the adapter is established The adapter is not receiving power or the cable connection is faulty Flashing The adapter is sending or receiving network data at 10 100 1000Mbps as indicated by the 10 100 1000 speed LED The adapter is receiving power and the cable connection is working Speed Off The adapter is connected at 10Mbps Green The adapter is connected...

Страница 8: ...be provided for the purpose of removing these hazardous conditions WARNING Installation of this adapter should be performed by individuals who are both qualified in the servicing of computer equipment and trained in the hazards associated with products capable of producing hazardous energy levels This adapter is intended to be installed in Certified UL or CSA ITE equipment having instructions for ...

Страница 9: ...from hot surfaces allow the drives and the internal system components to cool before touching them 3 Firmly seat the adapter in a PCI Express slot and secure the adapter bracket NOTE For 1U type servers you may need to replace the standard profile bracket with a low profile bracket See Installing a low profile bracket on page 9 4 Replace the access panel and plug in the power cord Installing a low...

Страница 10: ...ge may reduce the life expectancy of the device To prevent electrostatic damage Avoid hand contact by transporting and storing products in static safe containers Keep electrostatic sensitive parts in their containers until they arrive at static free workstations Place parts on a grounded surface before removing them from their containers Avoid touching pins leads or circuitry Always be properly gr...

Страница 11: ...2 1p QoS IEEE 802 1q VLAN tagging IEEE802 3z IEEE802 3ap IEEE802 3ae Dimensions 11 93 cm x 5 58 cm 4 7 in x 2 2 in L x W without bracket Connector and Distances 10BASE T Category 3 4 or 5 UTP 100 M 328 ft 100BASE TX CAT5 UTP 100 M 328 ft 1000BASE TX CAT5 UTP 100 M 328 ft Interrupts Supported Automatically configured Temperature Range Operating 0 C to 55 C 32 F to 131 F Storage 40 C to 85 C 40 F to...

Страница 12: ...ances for Gigabit over copper cable are 100 meters 328 feet To connect to the network the NC112T uses the following cable for 1000Base T transmission CAT5 UTP or better twisted pair 22 26 AWG 100Ω 1 MHz EIA TIA 568a or EIA TIA 568b ...

Страница 13: ... devices are those that may reasonably be expected to be installed in a residential environment for example personal computers The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user Class B equipment This equipment has been tested and found to comply with the limits for a Class B digital...

Страница 14: ...identify this product refer to the part series or model number found on the product Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett Packard Company may void the user s authority to operate the equipment Canadian notice This Class B digital apparatus meets all requirements of the Canadian Interfe...

Страница 15: ...its packaging indicates that this product must not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural re...

Страница 16: ...tic sensitive component or assembly Grounding methods to prevent electrostatic discharge Several methods are used for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance ...

Страница 17: ...ace CSA Canadian Standards Association DMA direct memory access IEEE Institute of Electrical and Electronics Engineers LED light emitting diode PCI Express Peripheral Component Interconnect Express PXE Preboot Execution Environment UTP unshielded twisted pair VDC voltage direct current WOL Wake on LAN ...

Страница 18: ...tions 4 E electrostatic discharge 10 16 F features 6 G grounding methods 16 I installation overview 8 installing adapters 9 L low profile bracket 9 N network cable 6 10 11 R regulatory compliance notices 13 15 S specifications 11 standards 13 T technical notes 4 telephone numbers 5 U UTP CAT5 cable 11 W warnings 4 Index ...