1. Using small bore hoses leads to
excessive restriction of the
water flow. The larger the
diameter of hose that you use
the better the performance of
the pump will be, especially
over long hose runs. The Hose
tail supplied with this unit will
accommodate 19mm (3/4"),
25mm (1"), 32mm (1.25") and
40mm (1.6") hose.
We would
always recommend that on
pumps of this size, that the
40mm diameter hose should be
used.
Once you have selected
the hose diameter you wish to
use, cut the steps off the Hose
tail which are smaller than the
hose diameter to eliminate
restriction (Fig 2). Attach a
suitable length hose to the
Threaded Hose tail and secure
with a suitable hose clip and
position the outlet end of the
hose in the desired position.
2. Screw the Threaded Hose tail
directly onto the outlet boss of
the ball joint (E in Fig 1). The
ball joint can be rotated to
allow the hose to be directed
away from the pump. Position
the pump as previously
described.
Wildlife Protection System.
If you have fish or other wildlife in
your pond, there are periods in
the year during which they may
breed. At this time the fish ‘fry’
are small and can be sucked into
the pump. To minimise this
possibility, the Titan range of
pumps has a unique Wildlife
Protection System which allows
you to reduce the inlet strainer
hole size down to 2mm at this
critical time in a fishes life cycle,
by moving the lever on the side of
the Strainer Cage (F in Fig1).
During the period when the
aperture size is reduced, you may
need to unblock the Strainer Cage
more frequently. Once the fish or
other wildlife have grown to a
sufficient size you can then return
the aperture size to its maximum
10mm size.
MAINTENANCE.
The Hozelock Cyprio range of
Titan pumps have been designed
to allow fast and easy
maintenance. As with all pumps of
its kind, occasionally it will
become necessary to clean the
Strainer Cage.
Always unplug or disconnect ALL
appliances in the pond from the
electricity supply before putting
your hands in the water or
starting maintenance.
Strainer.
1. Unscrew the Threaded Hose tail
from the pump outlet (E in Fig
1).
2. Rotate the three lid latching
knobs to the open position and
lift the Strainer Cage Top from
the Strainer Base (B in Fig 1).
3. Firmly pull the pump out of its
location using the handle and
wash/rinse the Strainer Cage
with clean water.
4. Reassemble the pump.
Rotor Assembly. (See Fig. 1)
1. Remove the Strainer Cage as
described above.
2. Release the Pump Chamber (G)
by rotating it until the two
retaining tongues are clear of
the lugs on the Motor Body.
3. Gently pull the Pump Chamber
squarely away from the Motor
Body (C).
4. Pull the Rotor Assembly (H) out
of the Motor Body.
5. Wash out all of the
components in clean water. Do
not use detergents or other
chemical cleaners.
6. Replace the Rotor Assembly into
the Motor Body and refit the
Pump Chamber and Strainer
Cage.
ALL YEAR PUMP CARE.
A quick daily check should be
carried out to ensure that the
pump is performing satisfactorily.
Once a month- Remove and clean
the Strainer Cage in accordance
with the general maintenance
notes. Depending on pond water
conditions, cleaning may be
required more frequently.
Once a year- Completely
disassemble the pump including
the Rotor Assembly as described in
the general maintenance
instructions and wash all
components in clean, fresh water.
Replace worn or broken parts.
SPARE PARTS.
Contact the Consumer Services
Helpline on 0121 313 1122
HOZELOCK CYPRIO 3 YEAR
GUARANTEE.
If this pump, excluding the Rotor
Assembly, becomes unserviceable
within 3 years of the date of
purchase it will be repaired or
replaced at our option free of
charge, unless in our opinion it
has been damaged or misused.
Liability is not accepted for
damage due to accident, improper
installation or use. Liability is
limited to replacement of a faulty
pump. This guarantee is not
transferable. It does not affect
your statutory rights.
To obtain the benefits of the
guarantee, firstly contact
Hozelock Cyprio Consumer
Services who may request that the
pump is sent along with proof of
purchase directly to the address
below.
Hozelock Cyprio Ltd.
Midpoint Park, Birmingham
B76 1AB. England
Telephone: 0121 313 1122
www.hozelock.com
FAULT FINDING.
Important - Please keep this section for reference.
LOW FLOW FROM PUMP
1.
Ensure the Strainer Cage is clean.
2.
A small diameter outlet pipe will restrict outlet flow.
NO FLOW FROM PUMP
1.
Check the power supply is on.
2.
Check the fuse and wiring.
3.
Check the Rotor Assembly is not jammed , damaged or
showing signs of excessive wear.
4.
Ensure the Strainer Cage is clean.
5.
The Thermal Protection has tripped. (see first paragraph).
Part No.
2000
3000
Spares
1. Pump Chamber
Z13415 Z13915
Assembly and Seal.
2. Rotor Assembly.
1460
1461
3. Strainer Cage
Z13426 Z13426
Assembly.
4. Threaded Outlet
1470
1470
Adapter.
5. Ball joint
Z13515 Z13515