Hozelock Flood Pump 7825 Скачать руководство пользователя страница 6

Troubleshooting

Problem

Possible Cause

Remedy

The pump does
not pump water
and the motor is
not running

No electricity

Check that the electricity supply is
turned on and that the pump is
correctly plugged in

Plug inserted incorrectly

Circuit breaker is
tripped

Reset electricity supply. 
If the circuit breaker trips once
more contact a specialised
electrician

Blocked impeller

Unplug from the electricity supply
and remove possible obstructions
from the impeller (Figs 8 & 9)

Damaged motor

Contact hozelock customer
services for assistance

Pump has overheated

Pump contains thermal
protection - check if pump case is
hot, and if so, allow to cool

Float switch is
preventing pump
turning on

The pump will only work when
the float switch is in the upright
position, ensure that is is able to
reach the vertical position

The pump
supplies a
limited amount
of water or the
pump does not
pump water,
and the motor is
running

Pump full of air

Unplug from the electricity supply
and disconnect outlet hose,
submerge in water and allow air
to escape, re-connect hose and
power

Obstructed inlet

Follow cleaning instructions
detailed in maintenance section
(Figs 8 &9)

Obstructed pipe/outlet

Remove obstructions in inlet hose
or kinks and clean out filter

Worn impeller

Contact Hozelock customer
services for assistance

33800 FloodPump Inst  2/10/07  08:51  Page 6