background image

the Strainer Cage and Fountain Spray head
ring.

Always unplug or disconnect ALL appliances
in the pond from the electricity supply before
putting your hands in the water or starting
maintenance.

Fountain Head

1.  Place a coin or similar in the slot and

gently lever off the fountain head.

2.  Rinse in clean water and reassemble.

Strainer.

1. Remove the strainer from the front of  the

pump by gently pulling it.

2.  Rinse the strainer with clean water and

then re-fit it.

Rotor Assembly.

1.  Remove the Strainer Cage as described

above.

2.  Release the Chamber Front Plate, by

unsnapping it from the Motor Body. See
Fig 5 (G).

3.  Gently pull the Chamber Front Plate

squarely away from the Motor Body.

4.  Pull the Rotor Assembly out of the Motor

Body. See Fig 5 (H).

5.  Wash out all of the components in clean

water. 

Do not use detergents or other

chemical cleaners.

6.  Replace the Rotor Assembly into the

Motor Body and refit the Pump Chamber
and Strainer Cage.

ALL YEAR PUMP CARE.

A quick daily check should be carried out to
ensure that the pump is performing
satisfactorily.

Once a week-

Remove and clean the Strainer

Cage and Fountain Head in accordance with

the general maintenance notes. Depending
on  water conditions, cleaning may be
required more frequently.

Once a year-

Completely disassemble the

pump including the Rotor Assembly as
described in the general maintenance notes
and wash all components in clean, fresh
water. Replace worn or broken parts.

HOZELOCK CYPRIO 3 YEAR
GUARANTEE.

If this pump, excluding the Rotor Assembly,
becomes unserviceable within 1 year of the
date of purchase it will be repaired or
replaced at our option free of charge, unless
in our opinion it has been damaged or
misused. 
Liability is not accepted for damage due to
accident,  improper  installation or use.
Liability is limited to replacement of a faulty
pump. This guarantee is not transferable. It
does not affect your statutory rights. 
To obtain the benefits of the guarantee,
firstly contact Hozelock Cyprio Consumer
Services who may request that the pump is
sent along with proof of purchase directly to
the address below.

DAMAGE CAUSED BY RUNNING THE PUMP
DRY OR BY FROST INVALIDATES THE
GUARANTEE.

Hozelock Cyprio

Midpoint Park, Birmingham B76 1AB
Tel: +44 (0)121 313 1122
www.hozelock.com

The Aquatics Division of Hozelock Group

33435-002

FAULT FINDING

WARNING: ALWAYS UNPLUG OR
DISCONNECT ALL APPLIANCES IN THE
POND FROM THE ELECTRICITY SUPPLY
BEFORE PUTTING YOUR HANDS IN THE
WATER WHILST EQUIPMENT IS BEING
INSTALLED, REPAIRED, MAINTAINED OR
HANDLED.

IMPORTANT - PLEASE KEEP THIS
SECTION FOR REFERENCE

LOW FLOW FROM PUMP

1. Ensure the Strainer Cage is clean.
2. A small diameter outlet pipe will

restrict outlet flow.

3. Clear any blockages and adjust the flow

controls.

NO FLOW FROM PUMP

1. Check power supply is on.
2. Check fuse and wiring.
3. Check the Rotor Assembly is not

jammed, damaged or showing signs of
excessive wear.

4. Ensure the Strainer Cage is clean.

POOR FOUNTAIN DISPLAY.

1. Clean the Fountain Head. (see

maintenance).

Fig. 4

Fig. 1

Fig. 3

Fig. 5

Fig. 2

A

B

C

F

D

E

G

H

PLEASE NOTE:
Do not dispose
of in household
waste

Отзывы: