These symbols are used throughout the instruction manual to alert the user to potential  

 safety hazards as follows : 
  

Warning

 

 Notice when incorrect handling could cause the user's death or serious 

                          injury. 
  

Caution

 

 Notice when incorrect handling could cause injury to the user or material 

                          damage.   
 Even if the instructions do not have  

Caution

  mark, there are some possibilities for a 

 serious situation.  Follow the instructions.

 

 Warning and caution symbols      

 

 

Precautions

 

1.   To prevent the unit from falling and possibly causing injury to personnel, do not  
      place this unit on unstable places, on tables with casters. 

 

2.   Do not unnecessarily remove the stereo head or the holder from the post or the  
      holder.  If it becomes necessary to remove them, hold them

 

with

 

both

 

hands to 

 

  

  prevent dropping them

 

and possibly causing injury to personnel.

 

 

Warning

 

1.   Do not disassemble or modify the L-51 yourself, otherwise this could cause a  

      malfunction.

 

2.   Always keep the lens filter in place to prevent dust or fumes from contaminating the  

      interior of the microscope. 

 

3.   When using the rubber mat, be sure to ground, otherwise this could damage the  

      object such as PCB.

 

4.   Protect the unit against physical shock or vibration during transport. Otherwise, this  

      could cause a malfunction. 
5.   Do not expose the unit to prolonged direct sunlight, high temperature, high humidity,  

      or dust. Such exposure could cause a malfunction.

 

 

Caution

 

 

Preparation

 

Settle the table accompanied by the post and the holder 

on an appropriate place. 
Put on the stage. Orient it pressing the spring at the end  

of the hole as shown in the photo. 

Choose black and white faces of the stage in accord-

ance with object to be inspected.

 

 

First, make sure that the contents are complete.

 

Procedures in case of not using the ESD rubber mat

 

Содержание L-51

Страница 1: ...ON MANUAL Specifications 200 W X255 D mm 3 8kg 133mm 282mm Stereo head spec Pupil distance range Post height Table dimensions Weight 10X 20X 1X 2X selection format Objectives Eyepieces Focusing Identi...

Страница 2: ...em and possibly causing injury to personnel Warning 1 Do not disassemble or modify the L 51 yourself otherwise this could cause a malfunction 2 Always keep the lens filter in place to prevent dust or...

Страница 3: ...n insert the eyepieces into the barrels Please use eyecups long if necessary How to attach the eyecup long 1 Remove the eyecup short 2 Attach the eyecup long as sown in the illustration Choose to suit...

Страница 4: ...en inspecting electronic components which are sensitive to static electricity Refer to page 8 regarding ESD measures Mount the holder on the post After this procedure refer to 2 5 of Procedures in cas...

Страница 5: ...could fall down suddenly damaging the unit the object and the operator Caution Adapt the eyepiece distance with your pupil distance to view a single circle of the field The stereo barrels will rotate...

Страница 6: ...tightly when transfer the L 51 Carefully work not to throw the table down Caution Choose magnification among 1X and 2X The working magnification is indicated by the stamp carved on the objective barr...

Страница 7: ...0 40 5 30 6 67 60 3 33 L 546 20 WF20X 40 5 80 2 5 27 27 L 57 2 Field of view mm X mm Field of view mm X mm Field of view mm X mm Field of view mm X mm Field of view mm X mm Field of view mm X mm Field...

Страница 8: ...Excerpted from RCJS 5 1 Item specific requirements 1 104 Rp 1 1010 1 Work surfaces Storage shelves Trolleys and Carts Point to point resistance Rp EPA ground resistance or resistance Rg of groundable...