background image

 

 Auto power off function

 

[Example] Changing the auto power off start time from 60 minutes to 30 minutes.

 

Setting the auto power off start time

 

Press the SET key to display “SUt”.

 

Press the 

key until the display 

changes to 30.

 

Press and hold the SET key until the set temperature is displayed. 

Setting is completed. Power will be turned off if there is no work for 30 minutes.

 

When auto power off time value is set to 0, the auto power off function is off. 
“Sdn” and the temperature are displayed alternately while the unit is in the auto pow-

er off mode and the LED under the one digit on the temperature window alone lights 

when the temperature becomes lower than 50

To use the unit again after auto power off, turn the power off and then on again.

 

● 

● 

● 

Press and hold the SET key until 

the display turns to “tPn” after  

temperature blinks.

 

Displayed

 

When the unit is not operated during the preset time, the unit is automatically turned pow-

er off. Even if the use forgets to turn off the unit, this auto power off function works to 

keep the unit inactive, and prevent accidents such as fire.

 

Explanation for auto power off

 

S

ol

der

in

g t

ip t

em

pe

rat

ur

e

 

Sensitivity

 

Sensitivity

 

Set temperature

 

Power off

 

Power ON

 

Time

 

Operation

 

Auto power 

off time

 

S

ol

der

in

g t

ip t

em

pe

rat

ur

e

 

Sensitivity

 

Sensitivity

 

Set temperature

 

Power off

 

Power ON

 

Time

 

Operation

 

Sleep setting 

temp.

 

Auto power 

off time

 

Sleep 

start time

 

This is the function that informs the temperature 

condition detecting the difference of set tempera-

ture and the actual tip’s temperature.   
When the tip’s temperature becomes out of set 

temperature, the buzzer will sound continuously 

and the alarm lamp will blink. 

 

 Setting the temperature range for the alarm

 

Explanation for alarm function

 

 Set temp.

 

Lower limit temp.

 

Upper limit temp.

 

Each limit of upper and lower temperature is able to set to 3

 to 100

. If set to a small 

value than 3, the alarm is canceled and [ - - - ] is displayed.  
The upper and lower limits are set to 50

 initially by the manufacturer.

 

Содержание HS-51-220

Страница 1: ...ction manual available for reference Standard tip 220V AC 10 50 60Hz 50 450 Tip with build in heater is sold separately 80W soldering iron 72W Heater External dimensions Station 115 W X98 H X146 D mm...

Страница 2: ...temperature control to the tip 4 Do not handle energized components This could cause a shock since the grip of the iron is made of conductive material 5 Do not modify this product 6 The tip becomes ex...

Страница 3: ...panel and functions are follows Power monitor lamp Illuminates when the power is supplied Sleep lamp Blinks when set sleep Blinks frequently 30 seconds before enter ing in sleep mode and illuminates...

Страница 4: ...t to be oxidized if the iron is heated without load Set less than 300 Previously put solder against the area to be soldered and wait until melts Caution Be sure that the power switch is turned off the...

Страница 5: ...the SET key Displayed Press the SET key Setting is completed If nothing is pressed for 30 seconds the temperature automatically returns to the temperature setting before it was changed The tip tempera...

Страница 6: ...Sleep setting temperature Power ON Time Operation Setting the sleep start time Press and hold the SET key until the set using temperature is displayed Setting is completed The unit will sleep if ther...

Страница 7: ...nsitivity as the standard for considering that there is no work is changeable The unit is set to 5 when sipping and will be in the sleep mode if the condition that the tip temperature does not rise or...

Страница 8: ...the unit is automatically turned pow er off Even if the use forgets to turn off the unit this auto power off function works to keep the unit inactive and prevent accidents such as fire Explanation for...

Страница 9: ...revent breaking objectives The alarm range can be set to 0 3 to 30 seconds If set to a small value than 0 3 the alarm is can celed and is displayed Explanation for soldering time The tip temperature b...

Страница 10: ...ver in some cases it is slightly different than values actually measured by a thermometer If you give priority to the results measured by a thermometer over this unit s display please calibrate the un...

Страница 11: ...s can be changed to Fahrenheit scale if desired Press and hold the SET key until the display turns to tPn after temperature blinks Displayed Range 3 100 0 999 0 3 30 SSt 50 450 0 4 50 50 0 Pt 50 0 00...

Страница 12: ...ips accord ing to your work How to change the tip Store the removed tips on the iron stand Drag the slide lever of the grip in the direction of Hold the black plas tic part and pull the tip out Plug t...

Страница 13: ...is required before starting soldering work Please reset as follows according to the number with a circle stamped near the root on the tip If change to a tip which has the same revise number revision...

Страница 14: ...es The unit is locked Each setting can be changed when locking is released It is locked when this operation is done under the lock released state It is release when this operation is done under the lo...

Страница 15: ...Press and hold the LOCK key until the display turns to display as bottom of the right illustration after turned to cod using the and keys display the usual cord number 123 Press the LOCK key using th...

Страница 16: ...dentification number is reset Press and hold the LOCK key and the key simultaneously until the display turns to dEc Memo Recording the registered number is recommended using the and keys display 471 T...

Страница 17: ...ace the tip or the iron with a new one This message is also displayed when changing the tip Please press any keys on the panel to reset The sensor or circuit in the tip is down The tip is set loosely...

Страница 18: ...y 2 Tool Rg 1 1012 1 There is no prescribed minimum resistance value for protecting an ESDS device However such a minimum resistance is required in some cases to ensure safety For details refer to the...

Страница 19: ......

Страница 20: ...19 11 1 2 12 Saiwaicho Naniwa ku Osaka 556 0021 Japan Tel 81 6 6567 3111 Fax 81 6 6562 0024...

Отзывы: