Quick Installation Guide
MI-600NT/MI-700NT/MI-800NT AP040266 REV1.1
2
/
2
B)
Push the AC connector of microinverter to the trunk cable connector until you hear
“click”.
C)
If there is any vacant bus port, please plug the AC sub cap on the vacant plug to
ensure for the water and dust prove.
*Note: Under the circumstances that need to remove the inverter AC cable from bus port,
please use the AC connector unlock tool and insert the tool into the side of AC port.
Step 3. Install AC End Cable
A)
Prepare the AC end cable with the proper length, and insert one side of the cable
into the cap. Match the L, N and Ground line into the slot accordingly. Tighten
the screws, and then tighten the cap back to the port. Plug the upper cover back
to the bus connector.
B) Connect the other side of the AC end cable to the distribution box, and wire it to
the local grid network.
Step 4. Create an Installation Map
A) Peel the removable serial number label from each microinverter (The position of
the label is shown as below).
B) Affix the serial number label to the respective location on the installation map.
Step 5. Connect PV Modules
A) Mount the PV modules above the microinverter.
B)
Connect the PV modules’ DC cables to the DC input side of the microinverter.
Step 6. Energize the System
A) Turn on the AC breaker of the branch circuit.
B) Turn on the main AC breaker of the house. Your system will start to generate
power after about two-minute wait time.
Step 7. Set Up the Monitoring System
Refer to the DTU User Manual or DTU Quick Install Guide, and Quick Installation
Guide for HMP Online Registration to install the DTU and set up your monitoring
system.