Hoymiles MI-300NT Скачать руководство пользователя страница 7

                                                                                     

 

©  2019  Hoymiles  Converter  Technology  Co.,  Ltd.  All  rights  reserved.                                            7   

 

MI-300NT/MI-350NT/MI-400NT 

 

Caution

     

Do not come within 8 inches (20cm) of the microinverter for any length of time 
while it is in operation.     

 

Danger of high voltages   

Danger to life due to high voltage in the microinverter.     

 

Beware of hot surface   

The  inverter  can  become  hot  during  operation.  Avoid  contact  with  metal 
surfaces during operation. 

 

FCC mark   

The inverter complies with the requirements of part 15 of FCC rules. 

 

Read manual first   

Please  read  the  installation  manual  first  before  installation,  operation  and 
maintenance. 

 

2.3 Radio Interference Statement 

 

This microinverter has been tested and found to comply with the limits for part 15 of FCC rules, which 
can provide reasonable protection against harmful energy. However, if not installed according to the 
instructions,  the  microinverter  may  cause  harmful  interference  to  radio  equipment.  There  is  no 
guarantee that the interference will not occur in a particular installation. 

To  confirm  that  the  radio  or  television  reception  is  interfered  by  this  equipment,  you  can  turn  the 
equipment  off  and  on.  If  this  equipment  does  cause  harmful  interference  to  the  radio  or  television 
equipment, please try to correct the interference by one or more of the following measures: 

1) Relocate the receiving antenna. 

2) Increase the separation between the microinverter and the receiving antenna. 

3) Place  the  shield  between  the  microinverter  and  the  receiving  antenna,  such  as  metal  / 
concrete roof. 

4) Contact your dealer or an experienced radio/TV technician for help. 

3. About Product 

3.1 About Single Unit   

“The  world’s  First  Daisy-Chain  Single  Unit  Microinverter”  with  extremely  wide  DC  input  operating 
voltage range (16-60V) and low start-up voltage (22V only). 

Содержание MI-300NT

Страница 1: ...Version 1 1 June 2020...

Страница 2: ...control the production of a single photovoltaic module directly consequently improving the flexibility and reliability of the system About the Manual This manual contains important instructions for t...

Страница 3: ...ghlights 8 3 3 Terminals Introduction 8 3 4 Dimension mm 8 4 About Function 9 4 1 Work Mode 9 5 About Installation 9 5 1 Accessories 9 5 2 Installation Precaution 10 5 3 Space Distance Required 10 5 4...

Страница 4: ...NT MI 400NT 8 Technical Data 22 8 1 DC Input 23 8 2 AC Output 23 8 3 Efficiency Safety and Protection 23 8 4 Mechanical Data 24 8 5 Features 24 Appendix 1 25 Installation Map 25 Appendix 2 26 WIRING D...

Страница 5: ...Important Safety Instructions The MI 300NT MI 350NT MI 400NT Microinverter is designed and tested according to iernational safety requirements However certain safety precautions must be taken when ins...

Страница 6: ...ipment when the safety devices do not work or disabled Use personal protective equipment including gloves and eye protection during the installation Inform the manufacturer about non standard installa...

Страница 7: ...ergy However if not installed according to the instructions the microinverter may cause harmful interference to radio equipment There is no guarantee that the interference will not occur in a particul...

Страница 8: ...O 1 CEC weighted efficiency 96 50 peak efficiency 96 70 in 2015 3 2 Highlights Peak output power up to 300W 350W 400W Adapted to 60 72 cells PV panels Peak efficiency 96 70 CEC weighted efficiency 96...

Страница 9: ...l circumstance that Microinverter will stay in Standby mode The current condition is contradicted with Microinverter operating requirement No house loads or the Export control value has been set as 0...

Страница 10: ...e countries the DTU will be required to meet the local grid regulation e g G98 99 for UK etc 5 3 Space Distance Required If the microinverters are installed on a concrete roof or steel roof the commun...

Страница 11: ...w around the inverter is not blocked Do not install in places where gasses or flammable substances may be present Avoid electromagnetic interference that can compromise the correct operation of electr...

Страница 12: ...ug the upper cover back to the bus connector 5 6 Installation Steps Step 1 Fix Microinverter on the Rail A Mark the approximate center of each panel on the frame B Fix the screw on the rail C Hang the...

Страница 13: ...please plug the AC sub cap on the vacant plug to ensure waterproof and dustproof Note Under the circumstances that need to remove the inverter AC cable from bus port please use the AC connector unlock...

Страница 14: ...rid network Step 4 Create an Installation Map A Peel the removable serial number lable from each microinverter The position of the label is shown as below B Affix the serial number label to the respec...

Страница 15: ...1 Over temperature protection 1 Check the ventilation and ambient temperature at the microinverter installation position 2 If the ventilation is poor or the ambient temperature exceeds the limit impro...

Страница 16: ...croinverter can recover automatically after grid voltage becomes normal 2 If the alarm occurs frequently check whether the grid voltage is within the acceptable range If no contact the local power ope...

Страница 17: ...outage Please check whether there is a power grid outage 148 Grid disconnection Please check whether the AC switch or AC wiring is normal 149 Island detected 1 If the alarm occurs accidentally the gr...

Страница 18: ...ccurs accidentally and the microinverter can still work normally no special treatment is required 2 If the alarm occurs frequently and cannot be recovered contact your dealer or Hoymiles technical sup...

Страница 19: ...inverter follow the steps in the order shown 1 Verify the utility voltage and frequency are within ranges shown in the in appendix Technical Data of this microinverter 2 Check the connection to the ut...

Страница 20: ...repairs In order to preserving the integrity of safety and insulation the Microinverters are not designed to allow internal repairs The AC output wiring harness AC drop cable on the Microinverter cann...

Страница 21: ...ind the device that you just replaced Please click the down arrow next to the More on the right side of the page and select Replace Input the new Microinverter s SN and click Ok to complete the statio...

Страница 22: ...ked The equipment must be stored in well ventilated indoor areas that do not have characteristics that might damage the components of the equipment Take a complete inspection when restarting after a l...

Страница 23: ...MI 350NT MI 400N Peak output power W 300 350 400 Maximum continuous output power W 295 349 382 Maximum continuous output current A 1 42 208V 1 23 240V 1 68 208V 1 45 240V 1 84 208V 1 59 240V Nominal o...

Страница 24: ...0 65 Storage temperature range 40 85 40 85 40 85 Dimensions W H D mm 178 153 28 Weight kg 1 75 Enclosure rating Outdoor NEMA IP67 Cooling Natural convection No fans Model MI 300NT MI 350NT MI 400NT Co...

Страница 25: ...2019 Hoymiles Converter Technology Co Ltd All rights reserved 25 MI 300NT MI 350NT MI 400NT Appendix 1 Installation Map...

Страница 26: ...IAGRAM 120VAC 240VAC SPLIT PHASE UP TO 10 MI 400NTs PER 20A AC BRANCH CIRCUIT GROUND NEUTRAL W AC DISTRIBUTION PANEL OR SUBPANEL METER AC BRANCH CABLE BROWN L BLUE N YELLOW GREEN G BRANCH END CAP L1 P...

Страница 27: ...N PANEL OR SUBPANEL METER AC BRANCH CABLE BROWN L BLUE N YELLOW GREEN G L1 L2 L3 ETHERNET CONNECTION TO BROADBAND ROUTER CONNECTION TO DTU POWER ADAPATER 5V DTU UP TO 99 MI 400NTs UP TO 10 MI 400NTs P...