Hoymiles HRSD-1C Скачать руководство пользователя страница 15

Rapid Shutdown User Manual

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

12

B ).

 - Pass either positive homerun or negative homerun through cores.

- Connect wires to AC side of power supply.

*The waterproof accessories are 
not supplied and need to be pre-
pared by the installer.

*Only positive homerun or negative   

  homerun through core

* AC Wires for PSU

*Only positive homerun or negative   

  homerun through core

*Only positive homerun or negative   

  homerun through core

Содержание HRSD-1C

Страница 1: ...Open Energy for All Rapid Shutdown HRSD 1C HT10 HT10 Kit USER MANUAL Region Global V202205 hoymiles com...

Страница 2: ...cts 01 1 1 HRSD 1C 02 1 2 HT10 03 1 3 HT10 Kit 04 2 System Overview 04 3 Installation Notes 05 4 Installation 06 4 1 HRSD 1C Installation 07 4 2 HT10 Installation 09 4 3 HT10 Kit Installation 11 4 4 C...

Страница 3: ...sume liability for loss or damage resulting from improper handling installation or misuse of products Do not attempt to install in inclement weather Be aware that the body of the running HRSD 1C is th...

Страница 4: ...h lower than arc noise No risk of triggering AFCI As part of Hoymiles rapid shutdown solution for PV system HRSD 1C can be connected with one module It meets NEC2017 NEC 2020 UL 1741 and Sunspec Rapid...

Страница 5: ...tter or using an external initiator The Transmitter HT10 is part of Hoymiles Rapid Shutdown solution When paired with Hoymiles rapid shutdown HRSD and powered on HT10 sends a permission to operate sig...

Страница 6: ...ure Includes power supply Hoymiles Transmitter HT10 Kit is part of a rapid shutdown solution when paired with Hoymiles rapid shutdown HRSD While powered on HT10 Kit sends a permission to operate signa...

Страница 7: ...RSD 1C starst in the OFF position and measures 1V at the output When power is supplied to the Transmitter the HRSD 1C turns ON and allows full PV module voltage The HRSD 1C constantly receives a permi...

Страница 8: ...HRSD 1C HRSD 1C is shipped in the OFF position and will measure 1V at the output when the permission to operate signal is not present Failing to follow the sequence of installation steps may result in...

Страница 9: ...ule frame HRSD 1C can be installed anywhere on the PV module frame Mounting Brackets Method 1 Recommended Allow a minimum of 1 5 cm of space between the roof and the HRSD 1C enclosure to ensure ventil...

Страница 10: ...PV module before connecting the HRSD 1C output cables in series If disconnecting HRSD 1C disconnect the HRSD 1C output cables from the string before disconnecting the input cables from the PV module C...

Страница 11: ...eads from power supply to Transmitter Connect Core to Transmitter HT10 If there is only one core that needs to be connected please connect Core 1 first Din Rail PSU Core 1 Transmitter Din Rail PSU Cor...

Страница 12: ...rved 09 B Pass either positive homerun or negative homerun through cores Connect wires to AC side of power supply Only positive homerun or negative homerun through core Only positive homerun or negati...

Страница 13: ...smitter HT10 Kit power supply must be on the same AC branch circuit as the inverter to meet rapid shutdown requirements When the PV system is operating the Power LED1 should be lit and the Signal LED2...

Страница 14: ...Kit If there is only one core that needs to be connected please connect Core 1 first L N 12 V 12 V GND 12V INITIATOR INITIATOR LED 1 LED 2 CORE 2 CORE 1 LED 2 Din Rail PSU Core 1 Transmitter 85 264VA...

Страница 15: ...omerun through cores Connect wires to AC side of power supply The waterproof accessories are not supplied and need to be pre pared by the installer Only positive homerun or negative homerun through co...

Страница 16: ...on to operate signal GRID Note Install HRSD 1C before powering on Transmitter HT10 Kit Transmitter HT10 Kit power supply must be on the same AC branch circuit as the inverter to meet rapid shutdown re...

Страница 17: ...Rapid Shutdown User Manual 2022 Hoymiles Power Electronics Inc All rights reserved 14 4 4 Conduit Drilling Guide Enclosure Drilling Guide for 75 Conduit Enclosure Drilling Guide for 1 Conduit...

Страница 18: ...put Voltage 1V Power Consumption 200mW Mechanical Input Connectors MC4 standard Input Cable Length 0 15m Output Connectors MC4 standard Output Cable Length 1 2m1 Dimensions 113 x 54 x 16mm Environment...

Страница 19: ...cted 2 Max Current per Core 75A 150A Max String Voltage 1500VDC Max Number of Strings per Core1 5 15 Mechanical Dimensions 93 x 36 5 x 53 mm Mounting Type DIN35 Rail Environmental Operating Temperatur...

Страница 20: ...f Strings per Core1 5 15 Mechanical Dimensions 198 5 x 298 x 179 mm Mounting Type Wall mounted Environmental Operating Temperature Range 40 C to 85 C 40 F to 185 F Outdoor Rating IP65 NEMA4 Compliance...

Отзывы: