Step 5. Connect PV Modules

Step 6. Energize the System

A )

  Mount the PV modules above the 

microinverter.

B )

  Connect the PV modules’ DC cables to the 

DC input side of the microinverter.

Note:

1. Tightening torque of the cap: 5.5±0.5 N·m. Please do not over-torque.

2. Torque of locking screw: 0.4±0.1 N·m.

3. Do not damage the sealing ring in the 3P-AC Trunk Connector during disassembly and assembly.

Step 4. Create an Installation Map

A )

Peel the removable serial number label from 

each microinverter.

B )

 

Affix the serial number label to the respective

location on the installation map (please refer 

to the appendix).

Note: 

1. Make sure that the 3P-AC Trunk Connectors are kept away from any water-channeling surface.
2. In case you need to remove the microinverter AC cable from 3P-AC Trunk Connector, please use

the 3P-AC Trunk Port Disconnect Tool and insert the tool into the side of AC Sub Connector to

complete the removal.

Product information is subject to change without notice. (Please download reference manuals at www.hoymiles.com).

C )

  Repeat the above steps to make all the 3P-AC Trunk Cables you need, then lay out the cable on the rail in the suitable 

position so that the microinverters can be connected to the Trunk connectors.

Step 3. Complete the AC Connection

Note: Please use DC extension cables.

- Prepare a segment of AC cable with suitable

lengthto connect to the distribution box, with

stripping requirements fulfilled.

- Insert the cable into the cap in a way that

theL1, L2, L3, PE and N lines are in correspond-

ing slots.

- Tighten the screws and tighten the cap back

to the port.

- Plug the upper cover back to the Trunk

connector.

Region: Global   AP040390   REV1.1        © 2020 Hoymiles Power Electronics Inc. All rights reserved.

02

B )

  Connect the AC end cable to the distribution box, and wire it to the local grid network.

A)

Turn on the AC breaker for the branch circuit.

B)

Turn on the main AC breaker for the house. Your

system will start to generate power in about two

minutes.

Step 7. Set up Monitoring System

Please refer to the DTU User Manual or DTU Quick Installation 

Guide, and Quick Installation Guide for S-miles Cloud to install 

the DTU and set up monitoring system.

D )

 

 Attach the 3P-AC Trunk Cable to the 

mounting rail and fix the cable with tie wraps.

A )

 

 Push the AC Sub Connector from 

microinverter to the 3P-AC Trunk Connector 

until it clicks.

C )

 

 Please plug the 3P-AC Trunk Port Cap in 

any vacant AC Trunk Port to make it water and 

dust-proof.

5.5±0.5N·m

0.4±0.1N·m

click

click

click

8±1mm

70±5mm

138264700571

138264700571

N

PE

L3

L2

L1

To sheet ______

To sheet ______

To sheet ______

To sheet ______

Sheet_____of_____

Hoymiles Microinverter Installation Map

Please Make N for North

1

A

B

C

D

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

COLUMN

ROW

AP040228    V1.3

Customer Information:

DTU Serial Number

Azimuth:
Tilt:

Panel type: