2. Installation Steps

1. Accessories

Step 1. Plan and install the Microinverter

All accessories above are not included in the package and should be purchased separately.

Note:

1. Install the microinverter and all DC connections under the PV module to avoid direct sunlight, rain exposure, snow buildup, UV, etc.

2. Leave at least 2 cm of space around the microinverter enclosure to ensure ventilation and heat dissipation.

3. Mounting torque of the 8 mm screw should be 9 N·m. Please do not over-torque.

The order of Step 1 and Step 2 can be reversed according to your planned needs.

Item

Description

A

3P-AC Trunk End Cap

B

3P-AC Trunk Connector

C

3P-AC Trunk Port Disconnect Tool

D

3P-AC Trunk Connector Unlock Tool

E

3P-AC Trunk Port Cap

F

G
H

DC Extension Cable,1m

 3P-AC Trunk Cable, 12/10 AWG Cable

- Use the 3P-AC Trunk Connector Unlock Tool

to unlock the connector upper cover.

1 )

  Disassemble the AC Trunk Connector and remove the cable.

2 )  Install the 3P-AC Trunk End Cap at one side of 3P-AC Trunk Cable (The end of 3P-AC Trunk Cable)

3 )  Install AC end cable on the other side of 3P-AC Trunk Cable (connected to the distribution box)

- Loosen the three screws with screwdriver.

Untighten the cap and remove the cable.

*Note: 

HMT-2250/1800-6T  Quick Installation Guide

A )

  Mark the position of each microinverter on the rail, according to the PV module layout.

Step 2. Plan and Build the 3P-AC Trunk Cable

B )  

Fix the screw on the rail.

C )  

Hang the microinverter on the

screws, and tighten the screws. The silver

cover side of the microinverter should be

facing the panel.

- Insert the 3P-AC Trunk End Cap and screw

the cap back to port, then tighten the cap.

- Unlock the port upper cover, loosen the screws

with screwdriver and remove the extra cable.

(Skip this step if there is no cable at this side.)

- Plug the upper cover back to the Trunk

connector.

5.5±0.5N·m

Mounting Torque : 9 N·m

click

B C D

E F

G

H

A

M8*25 screws (Prepared by the installer)

3P-AC Trunk Cable is used to connect the microinverter to distribution box.

A )

  Determine how many microinverters you plan to install on each AC branch and prepare AC Trunk Connectors 

accordingly.

B )

  Take out segments of AC Trunk Cable as you need to make AC branch. 