Single-phase Microinverter HMS-700/800/900/1000-2T-NA

Troubleshooting

143

Grid

Grid undervoltage

1. If the alarm occurs occasionally, the grid voltage may be just 

abnormal temporarily. The microinverter can automatically 

recover after grid voltage becomes normal.
2. If the alarm occurs frequently, check whether the grid 

voltage is within the acceptable range. If not, contact the local 

power operator or change the grid undervoltage protection 

limit in the grid profile via Hoymiles monitoring system with 

the consent of the local power operator.
3. If the fault still exists, check the AC switch or AC wiring.

144

Grid

Grid overfrequency

1. If the alarm occurs occasionally, the grid frequency may be 

just abnormal temporarily. The microinverter can automatically 

recover after grid frequency becomes normal.
2. If the alarm occurs frequently, check whether the grid 

frequency is within the acceptable range. If not, contact the local 

power operator or change the grid overfrequency protection 

limit via Hoymiles monitoring system with the consent of the 

local power operator.

145

Grid

Grid underfrequency

1. If the alarm occurs occasionally, the grid frequency may be 

just abnormal temporarily. The microinverter can automatically 

recover after grid frequency becomes normal.
2. If the alarm occurs frequently, check whether the grid 

frequency is within the acceptable range. If not, contact the local 

power operator or change the grid underfrequency protection 

limit via Hoymiles monitoring system with the consent of the 

local power operator.

146

Grid

Rapid grid frequency change 

rate

1. If the alarm occurs occasionally, the grid frequency may be 

just abnormal temporarily. The microinverter can automatically 

recover after grid frequency becomes normal.

2. If the alarm occurs frequently, check whether the grid 

frequency change rate is within the acceptable range. If not, 

contact the local power operator or change the grid frequency 

change rate limit in the grid profile in the grid profile via 

Hoymiles monitoring system with the consent of the local 

power operator.

147

Grid

Power grid outage

Please check whether the AC switch, branch breaker and AC 

wiring is normal.

148

Grid

Grid disconnection

Please check whether the AC switch, branch breaker and AC 

wiring is normal.

149

Grid

Island detected

1. If the alarm occurs occasionally, the grid frequency may be 

just abnormal temporarily. The microinverter can automatically 

recover after grid voltage becomes normal.

2. If the alarms occur frequently on all the microinverters in 

your station, contact the local power operator to check whether 

there is a grid island.

3.If the alarm still exists or happens on only serveral 

microinverters, please contact your dealer or Hoymiles technical 

support.

205

MPPT-A

Input overvoltage

1. Please make sure that the PV module open-circuit voltage is 

less than or equal to the maximum input voltage.

2. If the PV module open-circuit voltage is within the normal 

range, contact your dealer or Hoymiles technical support team.

206

MPPT-B

Input overvoltage

1. Please make sure that the PV module open-circuit voltage is 

less than or equal to the maximum input voltage.

2. If the PV module open-circuit voltage is within the normal 

range, contact your dealer or Hoymiles technical support team.

207

MPPT-A

Input undervoltage

1. Please make sure that the PV module open-circuit voltage is 

not lower than minimum input voltage.

2. If the PV module open-circuit voltage is within the normal 

range, contact your dealer or Hoymiles technical support team.

Содержание HMS-1000-2T-NA

Страница 1: ...Open Energy for All Single phase Microinverter HMS 700 2T NA HMS 800 2T NA HMS 900 2T NA HMS 1000 2T NA USER MANUAL Region North America V202201 hoymiles com...

Страница 2: ...ighly flexible and reliable as the system enables direct control of the production of each PV module About the Manual This manual contains important instructions for HMS 700 2T NA HMS 800 2T NA HMS 90...

Страница 3: ...4 1 Position and Space Required 10 4 2 Connecting Multiple PV Modules to Microinverter 10 4 3 Installation Tools 11 4 4 AC Branch Circuit Capacity 11 4 5 Precautions 12 5 Microinverter Installation 13...

Страница 4: ...tes a hazardous situation that can result in deadly electric shocks other serious physical injuries or fire incidents This indicates that directions must be strictly followed to avoid safety hazards i...

Страница 5: ...isconnect switches and Over Current Protection Devices OCPD Each input of the inverter is connected to one PV module Do not connect batteries or other sources of power supply The inverter can be used...

Страница 6: ...ger needed must be returned to an authorized dealer or approved collection and recycling facility Caution Do not come within 8 inches 20 cm of the microinverter when it is in operation Danger of high...

Страница 7: ...inverter is a module level solar inverter that tracks the maximum DC power point of each PV module which is known as Maximum Power Point Tracking MPPT This function of module level MPPT means that whe...

Страница 8: ...2 times longer distance than the 2 4GHz spectrum Interference Sub 1GHz wireless networking can handle interference better This is because it operates on a lower frequency so the communication between...

Страница 9: ...d 9 Single phase Microinverter HMS 700 800 900 1000 2T NA About Product Installation Preparation 3 7 Dimensions mm 3 6 Terminals Introduction Object Description A Sub 1G Wireless Terminal B DC Connect...

Страница 10: ...pace Required Please install the microinverter and all DC connections under the PV module to avoid direct sunlight rain exposure snow buildup UV etc The silver side of the microinverter should be up a...

Страница 11: ...4 208 V 5 240 V 4 208 V 4 240 V 3 208 V 4 240 V 20 A Maximum number per 10AWG branch 7 208 V 9 240 V 6 208 V 8 240 V 6 208V 7 240 V 5 208 V 6 240 V 30 A 4 4 AC Branch Circuit Capacity Hoymiles HMS 70...

Страница 12: ...ection Avoid direct sunlight to prevent power derating which can be caused by an increase in the internal temperature of the microinverter Keep the inverter in well ventilated place to avoid overheati...

Страница 13: ...H AC Trunk Connector Unlock Tool Note All accessories above are not included in the package and should be purchased separately About Installation 5 2 Installation Steps The order of Step 1 and Step 2...

Страница 14: ...sure ventilation and heat dissi pation 3 Mounting torque of the 8 mm screw is 9 N m Do not over torque 4 Do not pull or hold the AC cable with your hand Hold the handle instead Step 2 Plan and Build t...

Страница 15: ...the port Plug the upper cover back to the Trunk connector About Installation 2 Install the AC Trunk End Cap at one side of AC Trunk Cable the end of AC Trunk Cable 3 Install AC end cable on the other...

Страница 16: ...cable to the distribution box and wire it to the local grid network Product information is subject to change without notice Please download reference manuals at www hoymiles com click Step 4 Create an...

Страница 17: ...is required 2 If the alarm occurs frequently and cannot be recovered contact your dealer or Hoymiles technical support team 130 Offline 1 Please make sure that the microinverter works normally check i...

Страница 18: ...ncy may be just abnormal temporarily The microinverter can automatically recover after grid frequency becomes normal 2 If the alarm occurs frequently check whether the grid frequency change rate is wi...

Страница 19: ...check the DC cable connection between this port and the PV module 213 MPPT A PV 1 PV 2 abnormal wiring 1 Please check whether the DC connections on port 1 and 2 are correct 2 Check if the DC extension...

Страница 20: ...is abnormal Red flashes 0 5s gap Invalid AC grid or hardware failure Refer to Hoymiles Monitoring Platform for more details Red flashes 1s gap Not producing power due to invalid AC grid Solid red Har...

Страница 21: ...urself If the troubleshooting fails please return it to the factory for replacement 6 4 Routine Maintenance 1 Only authorized personnel are allowed to carry out the maintenance operations and are resp...

Страница 22: ...disconnect tool Remove the AC Sub Connector with AC disconnect tool Loosen the fixing screws on the top of the microinverter and remove the microinverter from the PV racking b How to replace the micro...

Страница 23: ...ays to avoid unforeseen injury Please examine the conditions of the components to be transported Upon receiving the microinverter you should check the container for any external damage and verify the...

Страница 24: ...r MPPT 1 Output Data AC Peak output power VA 700 800 900 1000 Maximum continuous output power VA 638 720 820 958 Maximum continuous output current A 2 66 3 07 3 3 46 3 42 3 94 3 99 4 61 Nominal output...

Страница 25: ...al electrical utility Simultaneous use of Fixed Power Factor and Volt Var is not supported Measurement Default Tolerance of Measurement Volts 1 Watts 5 VAr 6 Power factor 0 05 Hz 0 1 Hz Region Voltage...

Страница 26: ...ation N A N A Low Frequency 1 LF1 57 0 f 58 5 299 sec Mandatory Operation 300 sec 0 1 300 sec Low Frequency 2 LF2 f 57 0 No Ride Through Not Applicable 0 16 sec 0 16 sec Low Voltage 3 LV3 V 50 1 sec M...

Страница 27: ...HMS 900 2T NA HMS 1000 2T NA Output power rating W 638 720 820 958 Manufacturer s stated P f accuracy Prated 5 5 5 5 Maximum slope of frequency droop Prated Hz 100 100 100 100 Minimum slope of freque...

Страница 28: ...0 Appendix 1 10 1 Installation Map To sheet ______ To sheet ______ To sheet ______ To sheet ______ Sheet_____of_____ Hoymiles Microinverter Installation Map Please Make N for North 1 A B C D 2 3 4 5 6...

Страница 29: ...2022 Hoymiles Power Electronics Inc All rights reserved 29 Single phase Microinverter HMS 700 800 900 1000 2T NA 11 Appendix 2 11 1 WIRING DIAGRAM 120VAC 240VAC SPLIT PHASE...

Страница 30: ...2022 Hoymiles Power Electronics Inc All rights reserved 30 Single phase Microinverter HMS 700 800 900 1000 2T NA 11 Appendix 2 11 2 WIRING DIAGRAM 120VAC 208VAC THREE PHASE...

Отзывы: